Written and maintained by CASRAI Editorial Board
Published
On this page
A HAZOP study (hazard and operability study) is a structured examination of a system in which a multidisciplinary team, led by a trained study leader, applies a fixed set of guide words to each part of the design to find deviations from the design intent, then records their causes, consequences and recommended actions. IEC 61882:2016 is the international application guide, and OSHA names HAZOP as one of the process hazard analysis methods an employer may use under 29 CFR 1910.119(e)(2).
This page covers what the method is, the exact guide words in IEC 61882:2016, who sits on the team, what the OSHA rule says about the analysis, and how a team’s recommendations relate to the five levels of the hierarchy of controls. The data table below lists every guide word with its generic meaning. The broader question of which hazard analysis method suits which process is covered in the process hazard analysis guide; this page stays on HAZOP itself.
What is a HAZOP used for?
A HAZOP study is used to identify hazards, risks and operability problems in a system by examining how each part of it could depart from what it was designed to do. IEC 61882:2016 describes the technique as a guide for HAZOP studies of systems using guide words, covering definition, preparation, examination sessions, documentation and follow-up.
The IEC standard’s own introduction stresses two points that generic summaries often skip. First, the benefit is the knowledge gained by identifying potential hazards and operability problems in a structured, systematic way, which then helps in choosing appropriate remedial measures. Second, a HAZOP study should be seen as an enhancement to sound design based on experience, such as codes of practice, rather than a substitute for them. The study does not replace design standards; it tests a design that was meant to follow them.
The standard is not limited to chemical plant. Its own description of the examination process gives examples from three kinds of system: a chemical system, where the element “material” can be described by characteristics such as temperature, pressure and composition; a transport activity, where characteristics such as rate of movement, load or number of passengers may be relevant; and a computer-based system, where information, communication, interfaces and data processing are the subject. For research organisations this matters because the same logic can be applied to a pilot-scale reactor, a gas manifold or a data pipeline, provided the team defines the design intent first.
Definition and scope
Three terms carry the whole method, and the standard uses them consistently.
- Design intent. What a part of the system is meant to do. The team breaks the design intent of the selected part into separate elements, each described by discrete properties.
- Deviation. A departure from the design intent, found by a questioning process that uses predetermined guide words.
- Guide word. A short prompt that stimulates imaginative thinking, focuses the study and draws out discussion, which the standard says maximises the chances of study completeness.
IEC 61882 describes the examination as the characteristic feature of a HAZOP: a multidisciplinary team, under the guidance of a study leader, examines all relevant parts of a design or system systematically. The standard also states that the second edition (published 9 March 2016) cancels and replaces the first edition of 2001 and is a technical revision, with clarified terminology aligned to ISO 31000:2009 and ISO Guide 73:2009 and an improved case study of a procedural HAZOP.
How a HAZOP examination works
The standard describes the examination as a matrix. For each part under examination, the guide words define the rows and the element properties define the columns, so each cell is one specific guide word and property combination. The team applies each relevant guide word to each element property, then looks at the possible causes and consequences of the deviation that results, and at mechanisms for detecting or indicating failures. Results are recorded in an agreed format.
Two points from the standard are useful in practice:
- Not every cell is credible. The standard notes that not all combinations give credible deviations, so the matrix may have empty spaces. In general the study leader predefines the applicable guide word and property combinations so the team’s time and expertise are used efficiently.
- Two orders of examination. The cells can be worked column by column (element property first) or row by row (guide word first). The standard states that in principle the results should be the same.
An accurate and complete design representation of the system is a prerequisite for the examination, and the standard also allows a subset of the guide words to be applied to other attributes that matter to desired operation, such as access, isolation, control and the work environment (noise, lighting and so on).
The guide words in IEC 61882:2016
IEC 61882:2016 gives two example sets. Table 1 holds seven basic guide words, and Table 2 holds four guide words relating to clock time and to order or sequence. The standard calls them examples: additional guide words may be used, provided they are identified before the examination commences. The data table below lists all eleven with the generic meaning the standard assigns each.
A short reading of how the sets differ: the Table 1 words describe quantity and quality of the thing being examined (none of it, more, less, extra qualities, only part of it, the opposite, something else entirely), while the Table 2 words relate to timing and ordering and are the ones a procedural HAZOP, where steps are examined in sequence, leans on. That reading is an editorial interpretation of the table headings, not a statement from the standard.
Who is on a HAZOP team?
IEC 61882 describes a team of specialists from various disciplines with appropriate skills and experience, working under a trained and experienced study leader who must ensure comprehensive coverage of the system under study using logical, analytical thinking. The study leader is preferably assisted by a recorder, who records pertinent data on identified hazards, risks or operational disturbances for further risk analysis, evaluation and resolution.
OSHA’s rule sets its own minimum for facilities covered by the Process Safety Management standard. Under 29 CFR 1910.119(e)(4), the process hazard analysis must be performed by a team with expertise in engineering and process operations. The team must include at least one employee who has experience and knowledge specific to the process being evaluated, and one member must be knowledgeable in the specific analysis methodology being used. For a HAZOP, that last requirement lines up with the study leader role described in the IEC standard, although the regulation does not use the term.
HAZOP and the OSHA process hazard analysis rule
OSHA’s Process Safety Management standard, 29 CFR 1910.119, requires covered employers to perform a process hazard analysis (hazard evaluation) that is appropriate to the complexity of the process and that identifies, evaluates and controls the hazards involved. Paragraph (e)(2) lists the methods an employer may use, singly or together, as appropriate: What-If; Checklist; What-If/Checklist; Hazard and Operability Study (HAZOP); Failure Mode and Effects Analysis (FMEA); Fault Tree Analysis; or an appropriate equivalent methodology. HAZOP is therefore one named, accepted option, not a mandate.
The table below sets out the other elements of paragraph (e) that apply whichever method is chosen. Every row is taken from the text of the regulation.
| Paragraph | What it requires |
|---|---|
| (e)(3) | The analysis must address the hazards of the process; any previous incident with likely potential for catastrophic consequences; engineering and administrative controls and their interrelationships (including detection methods that give early warning of releases); consequences of failure of those controls; facility siting; human factors; and a qualitative evaluation of the possible safety and health effects of control failure on employees. |
| (e)(4) | A team with engineering and process operations expertise, including at least one employee experienced in the process and one member knowledgeable in the methodology. |
| (e)(5) | A system to promptly address the team’s findings and recommendations: resolve them in a timely manner, document the resolution and the actions to be taken, complete actions as soon as possible, set a written schedule, and communicate the actions to affected operating and maintenance employees. |
| (e)(6) | Update and revalidate the analysis at least every five years after the initial analysis, by a team meeting the (e)(4) requirements, so it stays consistent with the current process. |
| (e)(7) | Retain the analyses, updates and revalidations, and the documented resolution of recommendations, for the life of the process. |
Two consequences follow for anyone planning a study. A HAZOP worksheet on its own does not satisfy the rule: the recommendations must be tracked to documented resolution, and the analysis must be revalidated on a schedule. The IEC standard’s own scope, which includes documentation and follow-up, points the same way.
What are the 5 levels of hazard control?
NIOSH describes five levels in its hierarchy of controls, listed in this order: elimination, substitution, engineering controls, administrative controls and personal protective equipment (PPE). NIOSH words them as follows on its hierarchy of controls page, last reviewed 28 October 2026.
- Elimination removes the hazard at the source.
- Substitution is using a safer alternative to the source of the hazard.
- Engineering controls reduce or prevent hazards from coming into contact with workers.
- Administrative controls establish work practices that reduce the duration, frequency or intensity of exposure to hazards.
- Personal protective equipment is equipment worn to minimise exposure to hazards.
See the hierarchy of controls dictionary entry for the term itself. Where this connects to HAZOP: the OSHA rule requires the analysis to address engineering and administrative controls and the consequences of their failure, and the IEC standard has the team examine mechanisms for detecting or indicating failures. As an editorial suggestion, not something either document states, a team can sort its recommended actions against the NIOSH ladder to see whether a proposed fix removes the hazard or only relies on people and equipment worn. For lab-level assessments that end at the PPE rung, see PPE hazard assessment and written certification.
HAZOP compared with other hazard analysis methods
The regulation names HAZOP alongside What-If, Checklist, FMEA and Fault Tree Analysis, and does not rank them. Two points of contrast can be drawn directly from the sources read. HAZOP is a guide-word technique applied to elements of a design intent; the regulation lists the other methods separately and leaves the choice to the employer, subject to being appropriate to the process. For the difference between failure-mode analysis and root cause analysis, which is often confused with hazard analysis, see RCA vs. FMEA. For a laboratory view of identifying biological hazards before work begins, see biological risk assessment for laboratory protocols.
Common misunderstandings
- “HAZOP is only for oil and gas or chemical plants.” The IEC standard gives chemical, transport and computer-based examples, and describes a procedural HAZOP case study in its second edition.
- “Applying guide words is the whole study.” The standard covers preparation, examination sessions, documentation and follow-up. A study that stops at the worksheet has not reached follow-up.
- “Every guide word fits every property.” The standard says some combinations will not be credible and that the leader may predefine which apply.
- “The guide word list is fixed.” The two tables are examples, and extra guide words are allowed if defined before the examination starts.
- “A HAZOP can replace design codes.” The standard says it is an enhancement to sound design, not a substitute for experience-based approaches such as codes of practice.
Frequently asked questions
What is a HAZOP used for?
It is used to find hazards, risks and operability problems by examining deviations from the design intent of each part of a system with guide words, and to record causes, consequences and recommended actions (IEC 61882:2016).
What are the 5 levels of hazard control?
Elimination, substitution, engineering controls, administrative controls and personal protective equipment, in NIOSH’s hierarchy of controls.
Is HAZOP required by OSHA?
No method is mandated by name. 29 CFR 1910.119(e)(2) lets a covered employer use one or more listed methods that are appropriate to the process, and HAZOP is one of them, alongside What-If, Checklist, FMEA, Fault Tree Analysis and an appropriate equivalent methodology.
How often must a process hazard analysis be updated?
At least every five years after the initial analysis, by a team meeting the paragraph (e)(4) requirements, under 29 CFR 1910.119(e)(6).
What is the difference between a HAZOP and a job safety analysis?
A HAZOP examines a system or process design against its design intent using guide words. A job safety analysis examines a task. IEC 61882 is the application guide for the first, so use the method that matches what is being examined.
Sources
- OSHA: 29 CFR 1910.119, Process safety management of highly hazardous chemicals, checked 2026-11-20
- Cornell Legal Information Institute: 29 CFR 1910.119, checked 2026-11-20
- IEC 61882:2016, Hazard and operability studies (HAZOP studies), Application guide (catalogue preview), checked 2026-11-20
- CDC NIOSH: Hierarchy of Controls, checked 2026-11-20
Data: HAZOP guide words in IEC 61882:2016, with table and generic meaning
All eleven example guide words in IEC 61882:2016 (Edition 2.0, 2016): the seven basic guide words of Table 1 and the four time and sequence guide words of Table 2, each with the generic meaning the standard assigns and the kind of deviation it prompts. Compiled from the standard's published catalogue text; the standard says additional guide words may be used if defined before examination begins.
Period covered: 2016 edition.
| Guide word | IEC 61882:2016 table | Generic meaning (IEC 61882) | Aspect of deviation |
|---|---|---|---|
| NO OR NOT | Table 1 | Complete negation of the design intent | Basic |
| MORE | Table 1 | Quantitative increase | Basic |
| LESS | Table 1 | Quantitative decrease | Basic |
| AS WELL AS | Table 1 | Qualitative modification/increase | Basic |
| PART OF | Table 1 | Qualitative modification/decrease | Basic |
| REVERSE | Table 1 | Logical opposite of the design intent | Basic |
| OTHER THAN | Table 1 | Complete substitution | Basic |
| EARLY | Table 2 | Relative to the clock time | Clock time |
| LATE | Table 2 | Relative to the clock time | Clock time |
| BEFORE | Table 2 | Relating to order or sequence | Order or sequence |
| AFTER | Table 2 | Relating to order or sequence | Order or sequence |
Sources
- IEC 61882:2016 Hazard and operability studies (HAZOP studies) - Application guide (catalogue preview) (accessed 2026-11-20)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.







