Written and maintained by CASRAI Editorial Board
Published · Last updated
This page describes products and general use; it is not medical advice.
On this page
Is there a HCPCS code named thumb spica splint?
Not in the joint DME MAC and PDAC guidance on these braces. That article on upper-extremity braces, published in 2021 and still posted on the Medicare contractors’ sites, lists finger, hand, hand-finger and wrist-hand-finger orthosis codes and does not use the term “thumb spica” for any of them. The article ties each code to how the device is built and supplied, so the right code depends on the specific product.
Manufacturers and coders commonly cite codes from the wrist-hand-finger and hand-finger families for thumb products. Treat any such citation as a starting point to verify, not as an official assignment. For neighbouring devices, see the sibling guides on the HCPCS code for a finger splint and the HCPCS code for a wrist brace.
Thumb splint HCPCS code: the code families and what each descriptor says
The table reproduces the code, a shortened form of the official descriptor, and the article’s plain-language description of the device the code covers. Source: CGS Medicare (DME MAC Jurisdiction B), “Correct coding of finger, hand, hand-finger and wrist-hand-finger orthoses”, originally posted 28 October 2021 and revised 18 November 2021, checked 1 November 2026. Descriptors in the source are written in capitals; they are shown here in sentence case.
| Code | Descriptor | What the article says it describes |
|---|---|---|
| L3809 | Wrist hand finger orthosis, without joint(s), prefabricated, off-the-shelf, any type | Static prefabricated off-the-shelf (OTS) orthosis with support and/or immobilization to the wrist, hand and fingers |
| L3807 | Wrist hand finger orthosis, without joint(s), prefabricated item that has been trimmed, bent, molded, assembled, or otherwise customized to fit a specific patient by an individual with expertise | Static prefabricated custom fitted orthosis with support and/or immobilization to the wrist, hand and fingers |
| L3808 | Wrist hand finger orthosis, rigid without joints, may include soft interface material; straps, custom fabricated, includes fitting and adjustment | Static rigid custom fabricated orthosis with support and/or immobilization to the wrist, hand and fingers |
| L3924 | Hand finger orthosis, without joints, may include soft interface, straps, prefabricated, off-the-shelf | Static prefabricated OTS orthosis with support or immobilization of the metacarpophalangeal joints, hand and fingers |
| L3923 | Hand finger orthosis, without joints, may include soft interface, straps, prefabricated item that has been trimmed, bent, molded, assembled, or otherwise customized to fit a specific patient by an individual with expertise | Static prefabricated custom fitted orthosis with support or immobilization of the metacarpophalangeal joints, hand and fingers |
| L3913 | Hand finger orthosis, without joints, may include soft interface, straps, custom fabricated, includes fitting and adjustment | Static custom fabricated orthosis with support or immobilization of the metacarpophalangeal joints, hand and fingers |
| L3931 | Wrist hand finger orthosis, includes one or more nontorsion joint(s), turnbuckles, elastic bands/springs, may include soft interface material, straps, prefabricated, includes fitting and adjustment | Dynamic prefabricated custom fitted orthosis that supports the wrist, hand and fingers with one or more supportive non-torsion joints |
| L3929 | Hand finger orthosis, includes one or more nontorsion joint(s), turnbuckles, elastic bands/springs, may include soft interface material, straps, prefabricated item that has been trimmed, bent, molded, assembled, or otherwise customized to fit a specific patient by an individual with expertise | Dynamic prefabricated custom fitted orthosis that supports the hand and fingers with one or more supportive non-torsion joints |
The article states for each of the codes in the table that it is a complete device and that no add-on codes may be billed for the orthosis. The article mentions the thumb only in its discussion of L3912, an elastic finger-control glove; that code describes a glove, not a spica splint.
HCPCS code for thumb splint: prefabricated off-the-shelf, custom fitted or custom fabricated
Three terms in the descriptors separate otherwise similar codes. They are reading aids from the descriptors, not purchasing advice.
- Off-the-shelf (OTS): the descriptor reads “prefabricated, off-the-shelf” (for example L3809, L3924).
- Prefabricated custom fitted: the descriptor reads “prefabricated item that has been trimmed, bent, molded, assembled, or otherwise customized to fit a specific patient by an individual with expertise” (for example L3807, L3923).
- Custom fabricated: the descriptor reads “custom fabricated, includes fitting and adjustment” (for example L3808, L3913).
The same article separates static orthoses (support or immobilization, no joints) from dynamic ones (one or more non-torsion joints, such as rubber bands or springs), and it separates codes by the part of the limb the device supports: the metacarpophalangeal joints, hand and fingers (hand-finger family) versus the wrist, hand and fingers (wrist-hand-finger family). The article does not say which family a thumb-only product belongs to.
For the static versus dynamic distinction in splinting generally, see static vs dynamic splints; for a common thermoplastic used in custom splints, see Aquaplast.
How to verify the code for a specific product
- The source states that suppliers are required to correctly code the item billed, and that an item is correctly coded when it meets the coding guidelines in the CMS HCPCS guidelines, LCDs, LCD-related policy articles or DME MAC articles.
- Identify the exact product and how it is supplied: off-the-shelf, prefabricated and customized, or custom fabricated, and whether it spans the wrist.
- Ask the manufacturer whether the product has a code assigned through the PDAC and request that code in writing.
- For coding questions, the article names the PDAC HCPCS Helpline, (877) 735-1326, 9:30 am to 5:00 pm ET, Monday through Friday (as posted in the 2021 article; confirm the current contact on the PDAC website).
- Check the payer’s own policy.
- Confirm the descriptor against the current quarterly HCPCS Level II files. CMS maintains HCPCS Level II, including additions, revisions and deletions, and publishes quarterly updates; the 2021 article’s descriptors may have changed since.
Related reference: the durable medical equipment list.
Common mistakes
- Using a code copied from a product page as if it were an official assignment for every thumb spica.
- Choosing between a hand-finger and a wrist-hand-finger code without reading what joints the descriptor says the device supports.
- Ignoring the prefabricated off-the-shelf versus custom fitted versus custom fabricated wording in the descriptor.
- Billing add-on codes for these orthoses, when the article says each listed code describes a complete device with no add-on codes billable.
- Relying on a 2021 article without checking the current HCPCS files.
FAQ
What is the HCPCS code for a thumb spica splint?
No code in the 2021 DME MAC and PDAC article is named for a thumb spica splint. The code depends on the specific product’s construction and on any PDAC-assigned code for it, so verify with the manufacturer, the PDAC and the payer.
What is the thumb splint HCPCS code for a splint that does not cross the wrist?
The article’s hand-finger codes (L3923, L3924, L3913 for static devices) describe support of the metacarpophalangeal joints, hand and fingers, and its wrist-hand-finger codes describe support of the wrist as well. The article does not say which applies to a thumb-only device, so confirm the assigned code for the product.
Is the HCPCS code for a thumb splint the same for off-the-shelf and custom-made devices?
No. The descriptors distinguish off-the-shelf, prefabricated custom fitted and custom fabricated devices with separate codes, such as L3809, L3807 and L3808 in the wrist-hand-finger family.
Sources
- CGS Medicare, DME MAC and PDAC Joint Publication, correct coding of finger, hand, hand-finger and wrist-hand-finger orthoses (revised 18 November 2021): cgsmedicare.com. Checked 1 November 2026.
- Noridian Healthcare Solutions, JA DME, same article: med.noridianmedicare.com. Checked 1 November 2026.
- CMS, HCPCS Level II overview: cms.gov. Checked 1 November 2026.