Written and maintained by CASRAI Editorial Board
Published
On this page
High-NA EUV is extreme ultraviolet lithography with a numerical aperture (NA) of 0.55 instead of the 0.33 used by current EUV scanners. The larger aperture lets one exposure print finer patterns (ASML quotes an 8 nm resolution for its TWINSCAN EXE:5000), but it also halves the exposure field and tightens the limits on resists, masks and measurement.
Ask CASRAI · free to tryQuestion about this guide? Ask CASRAI answers with linked sources. 2 free questions a day, no account.
Short answer
“High NA” refers to the 0.55 numerical aperture of ASML’s EXE-class EUV scanners, compared with 0.33 for the earlier NXE class. Numerical aperture measures how wide a cone of light the projection optics can collect, and a wider cone resolves smaller features. ASML describes the TWINSCAN EXE:5000 as its first 0.55 NA system, with single-exposure features about 1.7 times smaller than the NXE class prints. The gain comes with real costs elsewhere in the process, which this page sets out from named sources.
Definition and scope
EUV lithography is the patterning step that transfers circuit layouts onto silicon wafers using extreme ultraviolet light. High-NA EUV (also written High NA EUV or EUVL at 0.55 NA) is the generation that raises the optics’ numerical aperture by 67 percent, from 0.33 to 0.55 (imec, 4 October 2021). It is a semiconductor-fabrication technology, not a laboratory instrument for general research, so this page covers what the term means and what the physics and process consequences are, not how to operate or buy a tool.
The term is a relative one. “High” is measured against the 0.33 NA systems that chipmakers use in volume production today, and the same word would not describe the optics of a microscope. For the general relationship between aperture and resolving power in imaging, see the CASRAI guide on the optical microscopy resolution limit.
How High-NA EUV works
Why a larger numerical aperture improves resolution
In projection lithography, the smallest printable feature shrinks as the numerical aperture grows. imec reports that the 0.33 NA production limit is around 13 nm (a 26 nm pitch), while 0.55 NA reaches 8 nm resolution, which corresponds to lines and spaces at a 16 nm pitch in a single exposure. As an editorial cross-check, scaling 13 nm by 0.33/0.55 gives about 7.8 nm, in line with the published 8 nm figure. That arithmetic is ours, not a figure either company states.
Anamorphic optics and the half-size field
The High-NA system uses anamorphic optics. According to ASML, it demagnifies 4x in one direction and 8x in the other, which means traditional-size reticles can still be used. The consequence is that the exposure field is half the size of the NXE field, so a wafer needs twice as many exposures to cover the same area. ASML states that the wafer stage accelerates at 8g, twice the NXE value, and the reticle stage at 32g, four times the NXE value.
ASML’s 2024 article states that the EXE:5000 is expected to handle more than 185 wafers per hour, with a roadmap to 220. Those are the manufacturer’s own statements from 2024 and describe an expected capability, not measured production data; they are not used in the comparison data below.
Contrast, dose and single exposure
ASML says the EXE:5000 delivers about 40 percent more imaging contrast than the NXE class and that its transistor density is 2.9 times that of NXE-based processes. The same page quotes a dose of 50 mJ/cm². ASML’s position is that a single High-NA exposure replaces process schemes that otherwise need several lower-NA exposures (multi-patterning), and that this simplifies the flow. The company also notes that the system reuses roughly twenty years of EUV technology and is designed for modular testing.
NA 0.33 versus NA 0.55 at a glance
The data table below this guide compares the two scanner classes across the figures that named sources give. Three points stand out when the numbers are read together.
- Resolution and pitch scale with NA. 0.55 NA reaches 8 nm resolution (16 nm pitch) against about 13 nm (26 nm pitch) at 0.33 NA, according to imec.
- Depth of focus moves the other way. imec explains that depth of focus scales with the square of the NA, giving 2 to 3 times less depth of focus than 0.33 NA in simulation. Editorial check: (0.55/0.33)² is about 2.78, inside imec’s 2 to 3 range.
- Throughput work shifts into the stages. Half the field means twice the exposures, which is why ASML highlights the faster wafer and reticle stages.
What changes beyond the scanner
imec’s overview makes the point that a higher-NA scanner is only one part of the system. Resists, masks and metrology all have to adapt, and each adaptation has a trade-off. The following table collects what imec reports for each area (imec, 2021; the field has moved on since, so treat these as the issues identified at that time).
| Area | What changes at 0.55 NA | Consequence reported by imec |
|---|---|---|
| Resist | Shallower depth of focus requires thinner resist films, under 20 nm | A thin film keeps a roughly 2:1 aspect ratio to avoid pattern collapse, but thinner resist increases line-edge and line-width roughness; metal-oxide resists were being evaluated against chemically amplified resists |
| Metrology | CD-SEM contrast falls on very thin films | Patterns stay visible down to about 15 nm film thickness; low-voltage SEM, helium-ion microscopy and scatterometry were examined as alternatives |
| Defects | Stochastic defects at small dimensions | Microbridges, broken lines and missing contacts; e-beam inspection is slow |
| Mask | Mask 3D effects of the multilayer and absorber | A Si/Mo multilayer of about 300 nm with a TaBN absorber is the baseline; new absorbers (low-n RuTa and PtMo, high-k PtTe and Ni) were studied |
| Die size | Half-size exposure field | Larger dies need two exposures stitched together |
| Pellicle | Protecting the mask from particles | Carbon-nanotube pellicle work was in progress |
imec also describes a joint High-NA Lab with ASML that brings together the tool, a coat-and-develop track and metrology so that these questions can be studied together before customers move into production.
Where it matters for fabs, labs and supply decisions
For people outside lithography, the practical reading is about where the constraints sit. High-NA EUV is a fab-side technology, and imec’s overview shows that its effects reach resists, masks, pellicles and metrology tools as well as the scanner. For the controlled environments that semiconductor and other precision processes commonly run in, see the CASRAI guides on cleanroom classifications and the clean room laboratory; the guide on wafer-level packaging covers a later step in the semiconductor flow.
ASML states that customers were running research and development on the first systems in 2024 and 2025, with high-volume manufacturing expected in 2025 to 2026, and that the first chips are targeted at the 2 nm logic node. These are the vendor’s stated expectations as of its 2024 article, and schedules and adoption decisions are made by the chipmakers, not by a published standard.
Common misunderstandings
Higher NA is a free win
It is not. The same optical change that improves resolution reduces depth of focus, which forces thinner resists, harder metrology and a different mask. The half-size field also means more exposures per wafer and stitching for large dies. ASML argues the net result is a simpler and better process than multi-patterning at 0.33 NA; the trade-offs above are why that is a decision for each chipmaker and each layer.
8 nm is the size of the transistors
The 8 nm figure is a resolution limit of the optics, expressed as a critical dimension that can be printed in a single exposure (16 nm pitch lines and spaces). ASML’s own page separates the two ideas: the 8 nm figure describes what the tool resolves, while “2 nm node” names the process generation the first chips are aimed at.
High NA means a different light source
No. “High NA” describes the numerical aperture of the optics, from 0.33 to 0.55; it says nothing about the source.
Stage accelerations or throughput numbers are settled
Throughput figures quoted for the EXE:5000 come from the manufacturer’s statements and roadmap. Check the vendor’s current documentation rather than treating a 2024 article as a specification.
Frequently asked questions
What does High-NA EUV mean?
It means extreme ultraviolet lithography with a numerical aperture of 0.55, compared with 0.33 for the earlier systems. ASML’s TWINSCAN EXE:5000 is described by the company as its first 0.55 NA system.
How small a feature can High-NA EUV print?
ASML quotes a resolution of 8 nm. imec expresses the same capability as lines and spaces at a 16 nm pitch in a single exposure, against about 13 nm (26 nm pitch) as the 0.33 NA volume-manufacturing limit.
Why is the exposure field smaller?
Anamorphic optics demagnify 4x in one direction and 8x in the other, so the field on the wafer is half the size of that of the NXE class. A wafer needs twice as many exposures, according to ASML.
What happens to depth of focus?
It shrinks. imec reports that depth of focus scales with NA squared and is 2 to 3 times lower than at 0.33 NA, which is why resist films must be thinner than 20 nm.
Does High-NA EUV replace the 0.33 NA systems?
The named sources do not say that it replaces them. ASML describes High-NA as a way to avoid multi-patterning on selected layers, and the sources read for this page do not give a layer-by-layer split between the two classes.
Sources
- ASML, TWINSCAN EXE:5000, product page, read 2026-11-14.
- ASML, 5 things you should know about High NA EUV, 2024, read 2026-11-14.
- imec, High-NA EUVL: a leap in resolution, published 4 October 2021, read 2026-11-14.
Data: Single-exposure EUV scanner parameters: 0.33 NA versus 0.55 NA
Compares the 0.33 NA (NXE class) and 0.55 NA (EXE class) EUV scanner classes on numerical aperture, resolution, pitch, stage acceleration and field size. Compiled from ASML product and article pages and an imec overview; the NXE stage values are derived from ASML's statement that the EXE stages are 2x and 4x the NXE values.
Period covered: 2021/2024.
| Parameter | 0.33 NA (NXE class) | 0.55 NA (EXE class) |
|---|---|---|
| Numerical aperture | 0.33 | 0.55 |
| Resolution limit (nm) | 13 | 8 |
| Line/space pitch in a single exposure (nm) | 26 | 16 |
| Exposure field (relative to NXE field) | 1 | 0.5 |
| Wafer stage acceleration (g) | 4 | 8 |
| Reticle stage acceleration (g) | 8 | 32 |
Sources
- ASML TWINSCAN EXE:5000 (accessed 2026-11-14)
- ASML: 5 things you should know about High NA EUV (accessed 2026-11-14)
- imec: High-NA EUVL: a leap in resolution (accessed 2026-11-14)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.