A histology cassette is a small perforated plastic holder that contains a tissue specimen while it is processed, embedded in wax and sectioned. The FDA lists the device as “Cassettes, Tissue” (product code IDZ), a Class I, premarket-exempt pathology accessory. Cassettes differ mainly in opening size and shape, lid design, number of chambers and depth.

This page describes products and general use; it is not medical advice.

What is a histology cassette? Definition and scope

In the AccessGUDID record for the Epredia Tissue Cassette I, the cassette is described as designed to contain incised tissue for processing, embedding and sectioning. The same record gives its GMDN term as “Histology tissue cassette IVD, laboratory processing, single-use” (GMDN 62970), and it lists the device as single-use and not sterile. The cassette is therefore a consumable, not a reusable piece of laboratory equipment.

The cassette travels with the specimen through each stage of tissue processing, so its job is containment, fluid exchange and identification. The openings (pores or slots) let fixatives, solvents and wax reach the tissue while keeping the specimen inside. The closed lid keeps it from escaping. A flat, angled writing face on many designs carries the specimen identifier through the workflow. For where this fits in the wider workflow, see the histopathology guide, the paraffin bath guide and the microtome guide.

Cassette, mold and slide are different items

The cassette is not the same as the embedding mold or the glass slide. The manufacturer page from Ted Pella lists separate “Tissue Cassette Bases” with a stainless steel cover, designed to fit microtome chuck adapters, which shows that some products are made to be held in the microtome itself. The cut sections end up on slides, which the microscope slide preparation guide covers.

How histology cassettes are used in practice

The MIT Koch Institute histology SOP, “Types of Tissue Cassettes and How to Use Them”, opens with a plain point: there are multiple styles and colours of cassettes, and many places colour code projects or specimens, which explains the variety of colours. The AccessGUDID entry says the same thing from the manufacturer side: colours may be used to identify patient or tissue type.

The same SOP describes several accessories used with standard cassettes:

  • Teflon biopsy bags. They can be used inside standard cassettes to hold very small tissue so it does not fall out, and they can hold floppy membranes and prevent them from fragmenting. The SOP says the tissue goes in the bottom half of the bag, which is folded in half and placed in the cassette.
  • Biopsy sponges. Tissue such as skin or resected bowel or tumour portions tends to curl while it fixes and processes. The SOP describes sandwiching the tissue between two sponges inside a standard cassette to hold it flat, and shows how a specimen looks when this is not done: curled and difficult to orient for a clean view.
  • Macro or “double deep” cassettes. The SOP points to these for very large items, such as tissue carrying a drug delivery device that should not shift during processing, with an example of a cross section of the abdominal cavity with injected material or nanoparticles.
  • Multi-well cassettes. The SOP notes that the chambers are numbered, so each piece of tissue can be identified.

These are laboratory handling notes for research tissue from a core facility’s own procedure. They are not clinical instructions, and a laboratory’s own SOP governs how it handles its specimens. For the identification side of specimen handling, see the specimen labeling error prevention guide.

Types of histology cassette

The AccessGUDID record for the Epredia cassette says the three types of that range differ in the size and shape of the pores: Embedding, Biopsy and Slotted. It adds that the choice of pore type is based on tissue type, tissue size and processing capabilities, and that the Thinline and Fine Pore versions have intermediate pore sizes. A “Histoscreen” variant uses a nylon mesh filter instead of pores, intended for small, friable tissue. Ted Pella uses its own product names for comparable designs, so the opening geometry is best read from the specification.

Standard (embedding and slotted) cassettes

Standard cassettes are the default container for routine-sized specimens. On the Ted Pella manufacturer page, the Unisette is made of acetal polymer with 1 mm square pores and a snap-latch lid; its outside dimensions are 28.5 x 41 x 6.7 mm and the inside is 26 x 30 x 5 mm. The Slimsette Tissue cassette is made of high-density acetal resin and has 114 slots of 1 x 5 mm, a 4 mm chamber depth, a recessed pre-assembled cover and a 45 degree writing surface.

Biopsy and mesh cassettes

The MIT SOP notes that biopsy cassettes have smaller openings so tissue will not fall out during processing. The Ted Pella page lists the Slimsette Biopsy with 0.8 mm pores and the Micromesh Biopsy with about 1,676 openings of 0.38 mm in a 27 mm compartment, and states that no biopsy pads are needed with the Micromesh design.

Multi-chamber cassettes

Multi-chamber cassettes divide the space so that several small pieces can be processed together with each in its own compartment. Ted Pella lists a Four Chamber design with four 13 mm square compartments and the Microsette I six-chamber, which is polypropylene, with more than 3,000 openings of 0.26 mm and compartments of 7 x 12 mm.

Macro cassettes

The Macrosette is listed at 40.1 x 28.5 x 13 mm with a maximum specimen thickness of 10 mm, which is roughly twice the 6.0 to 6.7 mm depth of the standard cassettes in the sources above.

The data table below compares these cassettes by type, opening geometry and dimension. Every value is as listed on the manufacturer page, and sizes are manufacturer-specific.

Materials and chemical resistance

Acetal (acetal copolymer) is the material named for the standard cassettes in both sources. The AccessGUDID record describes the acetal copolymer as solvent resistant during normal tissue processing. Ted Pella states that its acetal cassettes are resistant to the chemical action of histological solvents, and that the Slimsette is compatible with histological reagents and solvents. The Microsette I six-chamber is the exception in the sources here, being made of polypropylene.

The record also contains a warning that matters for handling: specimen security is guaranteed only with approved or tested lids, and non-approved lids may detach during processing. A cassette body and lid are therefore best treated as a matched pair from one manufacturer, because the claim of security depends on the lid the manufacturer tested.

Where it matters for laboratories and supply decisions

Regulatory status

The FDA product classification database (openFDA, checked 2026-11-17) returns one record for product code IDZ: device name “Cassettes, Tissue”, device class 1, regulation number 864.3010, medical specialty Pathology, with the GMP-exempt flag set. The regulation, 21 CFR 864.3010, is titled “Tissue processing equipment” and identifies these devices as devices used to prepare human tissue specimens for diagnostic histological examination by processing specimens through the stages of decalcifying, infiltrating, sectioning and mounting on microscope slides. It classifies them as Class I (general controls), exempt from the premarket notification procedures of 21 CFR part 807 subpart E, subject to the limitations in 21 CFR 864.9, and exempt from the current good manufacturing practice requirements of 21 CFR part 820 except for records and complaint files under 21 CFR 820.35. The AccessGUDID record agrees: it marks the device as exempt from premarket submission.

Class I status describes the FDA’s regulatory treatment of the device. It does not rate quality or fitness for any particular protocol.

Specification items a catalogue entry should state

The specifications that distinguish one product from another are the ones a manufacturer publishes. Drawing on the sources above, the items that differ across the products are:

  1. Opening type and size (square pores, slots, round pores or mesh, in millimetres).
  2. Number of chambers and the dimensions of each.
  3. Outside and inside dimensions, and depth (6.0 mm in the Epredia record, 6.7 mm for the Unisette, 13 mm for the Macrosette).
  4. Lid style: snap-latch, recessed pre-assembled cover, or separate cover.
  5. Material (acetal, acetal copolymer or polypropylene in these sources).
  6. Colour, where it is used for identification.
  7. Whether the lid is an approved lid for that cassette.

Dimensions are also published per range: the Epredia record states that all of its cassettes except the Thinline and Fine Pore versions measure 42.5 mm high, 28.5 mm wide and 6.0 mm deep. The width of 28.5 mm matches the Unisette and Macrosette widths on the Ted Pella page, though the heights and depths differ.

Common misunderstandings

“A larger pore is always better for fluid exchange”

The sources do not rank pore sizes. They say that the choice of pore type depends on tissue type, tissue size and processing capabilities, which means the right opening is a function of the specimen. Very small or friable tissue is the stated reason for the finer-pore, mesh and biopsy designs.

“All cassettes are interchangeable with any lid”

The AccessGUDID description specifically warns that non-approved lids may detach during processing and that security is stated only for approved or tested lids.

“Class I means no rules apply”

Class I devices are subject to general controls. The exemptions in 21 CFR 864.3010 are specific: premarket notification and most quality system requirements are exempted, while records and complaint files under 21 CFR 820.35 are not.

“Colour means a standard category”

Both the MIT SOP and the AccessGUDID record describe colour as something laboratories use to identify projects, specimens, patients or tissue types. Neither source defines a universal colour code, so a laboratory’s colour scheme is local to that laboratory.

“A cassette is reusable laboratory equipment”

The AccessGUDID record classifies the device as single-use and not sterile. A biopsy bag or sponge placed inside a standard cassette is a separate accessory item, not a cassette.

Sources

Data: Histology cassette types by opening geometry and dimensions

Original compilation of cassette designs from one manufacturer product page (Ted Pella tissue processing cassettes), grouped by the cassette categories described in the MIT Koch Institute histology SOP and the AccessGUDID record. Each value is as listed by the manufacturer; sizes are manufacturer-specific.

Histology cassette types by opening geometry and dimensions
CassetteCategoryOpening geometrySize detail
UnisetteStandard1 mm square poresOutside 28.5 x 41 x 6.7 mm; inside 26 x 30 x 5 mm
Slimsette TissueStandard (slotted)114 slots, 1 x 5 mmChamber depth 4 mm
Slimsette BiopsyBiopsy0.8 mm poresNot listed
Micromesh BiopsyBiopsy (mesh)About 1,676 openings, 0.38 mm27 mm compartment
Four ChamberMulti-chamberNot listedFour 13 mm square compartments
Microsette I six-chamberMulti-chamberMore than 3,000 openings, 0.26 mmCompartments 7 x 12 mm
MacrosetteMacroNot listed40.1 x 28.5 x 13 mm; maximum specimen thickness 10 mm

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Histology Cassette: Types, Pore Sizes, Materials and FDA Class

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →