Hospital Bassinet: FDA Class II Rules and Label Check

A hospital bassinet is a Class II, non-powered medical device under 21 CFR 880.5145. See its parts, required testing and the tipping-warning label.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

General product information, not medical advice. This page explains how federal regulation defines a hospital bassinet; it does not advise on the care of any individual infant.

Short answer

A hospital bassinet is, in FDA terms, a “medical bassinet”: a non-powered, wheeled bed for infants from birth to about 5 months, used in nurseries, labor and delivery units and patient rooms. It is a prescription device, Class II with special controls, regulated under 21 CFR 880.5145 (checked 2026-11-01).

Definition and scope

21 CFR 880.5145 describes a medical bassinet as a small bed for pediatric patients, generally from birth to approximately 5 months of age, intended for medical purposes in a nursery, labor and delivery unit or patient room. The regulation notes it may also be used outside traditional health care settings.

Two features set it apart from other infant equipment on a ward. It is non-powered, so it has no heating element or electronics. That is the main difference from an infant radiant warmer, which is a separate powered device with its own FDA classification. And it is not a weighing or measuring device: scales, length boards and infantometers are covered in the guide to the infant scale.

How it is built and used in practice

The regulation names two components:

  • Basket or bed: a box-like structure, generally made of clear, high-impact-resistant plastic, with an open top and four stationary walls to hold the infant.
  • Frame with wheels: a durable frame that holds the basket. It can include drawers, shelving or cabinetry for infant care items, and its wheels or casters let staff transport the infant through the care setting.

Because the frame is a wheeled, storage-bearing piece of furniture, the same caster and cabinet questions arise as for other ward equipment; the medical cart accessories guide covers that neighboring category.

What the FDA rule requires: a checklist

The regulation lists what a manufacturer must demonstrate and print on the device. Classification under 880.5145(b) is Class II (special controls); the device is exempt from premarket notification under subpart E of part 807, subject to 21 CFR 880.9 limitations. The final rule was published December 19, 2016 (81 FR 91737).

Requirement What the regulation says
Cleaning compatibility The manufacturer must test material compatibility with the cleansing products labeled for the device; the cleaning instructions must not cause crazing, cracking or deterioration.
Mechanical and structural stability Testing under expected conditions of use, including transport of patients, must show that failures such as wheel or caster breakage do not occur and that no mechanical failure creates a tipping hazard.
Care instructions Each device must carry adequate instructions for users to care for, maintain and clean the bassinet.
Tipping warning A warning label on at least two sides of the plastic basket, in text at least 9 millimeters high, telling users to make sure the basket sits firmly in the base and that all doors, drawers and casters are secure.

Where it matters for labs, clinics and supply decisions

For staff who maintain or document equipment, the table converts directly into a label and instructions check. These points follow from the text of the regulation, not from any purchasing rule:

  • Is the tipping warning present on at least two sides of the basket, and still legible at the required size?
  • Are the manufacturer’s care, maintenance and cleaning instructions available for the unit, including which cleaning products the label names?
  • Are the basket, doors, drawers and casters secure, as the warning label itself tells users to confirm?

The cleaning point links to a wider topic. The special control ties compatibility to the products the manufacturer labels, so a disinfectant outside that list is a question for the instructions, not a guess. The guide to types of disinfectants explains how to read product label claims, and vinyl mattress covers covers a related surface in patient-care settings.

Bassinets also appear in security planning on maternity units; see the infant abduction prevention program guide.

Common misunderstandings

“A bassinet is just furniture”

For the medical version, the regulation classifies it as a prescription device in Class II with defined special controls.

“Class II means FDA cleared each model first”

This device type is exempt from premarket notification (subpart E of part 807), subject to the limitations in 21 CFR 880.9. Exempt does not mean the special controls do not apply.

“It keeps the infant warm”

A medical bassinet is defined as non-powered. Heating is the function of a different device; see the infant radiant warmer guide linked above.

“Infant weighing and length measurement come with the bassinet”

Not under this regulation. Infant scales, length boards and infantometers are separate equipment, covered in the infant scale guide.

FAQ

What is a hospital bassinet?

A small, non-powered, wheeled bed with a clear plastic basket on a frame, used for infants from birth to about 5 months in nurseries, labor and delivery units and patient rooms (21 CFR 880.5145).

What FDA class is a hospital bassinet?

Class II with special controls, exempt from premarket notification subject to 21 CFR 880.9.

What warning must appear on it?

A tipping-hazard warning on at least two sides of the basket, in text at least 9 millimeters high, telling users to make sure the basket sits firmly in the base and that all doors, drawers and casters are secure.

What does the cleaning requirement mean?

The manufacturer must show that its labeled cleaning products and instructions do not cause crazing, cracking or deterioration of the device.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Hospital Bassinet: FDA Class II Rules and Label Check

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →