Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
Organizing a laboratory notebook requires establishing a bound, tamper-evident record or validated electronic system structured by chronological entries, comprehensive front-matter indexes, standardized 8-part experimental logs, and strict Good Documentation Practices (GDP). Under regulatory frameworks such as FDA 21 CFR § 58.130 and the ALCOA+ data integrity framework (Attributable, Legible, Contemporaneous, Original, Accurate), every entry must capture raw observations promptly in indelible ink, avoid obliterations through single-line strike-through corrections, cross-reference external datasets, and secure timely witness countersignatures to maintain legal defensibility and experimental reproducibility.
What you need
Proper laboratory notebook organization begins with selecting physical or digital materials engineered to withstand chemical exposure, physical handling, and multi-decade archival storage. Using inappropriate materials, such as spiral-bound pads, loose binders, or water-soluble pens, compromises the legal integrity of scientific records and frequently leads to audit citations under Good Laboratory Practice (GLP) standards.
Physical Notebook Specifications
For facilities utilizing paper-based documentation, physical notebooks must satisfy rigorous archival criteria:
- Permanent Sewn Bindings: Notebooks must feature Smyth-sewn or section-sewn hardcover bindings. Spiral bindings, comb bindings, and three-ring loose-leaf binders are prohibited because pages can be removed or inserted without physical evidence of tampering.
- Pre-Numbered Sequential Pages: Every leaf must carry consecutive, factory-printed page numbers. If a page is accidentally skipped, it must be struck through with a diagonal line, dated, and initialed; torn-out pages constitute an immediate integrity breach.
- Archival Acid-Free Paper: Paper stock should consist of 80 to 100 gsm acid-free (pH-neutral), lignin-free cellulose. This prevents paper yellowing, embrittlement, and degradation when exposed to laboratory atmospheric conditions or decades of storage.
- Grid or Lined Ruling: A 5 mm grid or 6 mm horizontal ruling printed in non-reproducing blue or subtle grey ink provides layout guidance for tables, chemical reaction schemes, and instrumentation sketches without obscuring handwriting.
- Pre-Printed Front Matter Blocks: Bound notebooks should feature dedicated front pages for a Table of Contents, researcher contact details, issuance and closure dates, and standardized page header and footer blocks.
Writing Instruments and Media Consumables
Writing media must permanently bond with the paper substrate to resist fading, light exposure, moisture, and chemical spills:
- Indelible, Chemical-Resistant Ink: Entries must be written exclusively with archival pigment-based pens (such as Pigma Micron or certified archival ballpoint pens) using black or dark blue ink. Graphite pencils, erasable pens, and water-soluble felt markers are prohibited. Black pigment ink is preferred because it provides optimal contrast during scanning and microfilming.
- Archival Adhesives for Secondary Attachments: When mounting instrumentation readouts (such as spectrophotometer printouts, thermal printer strips, or thin-layer chromatography plates), use pH-neutral, acid-free glue sticks or archival double-sided polyester tape. Liquid glues, cellulose tape, staples, and paperclips must be avoided; staples cause mechanical tearing and rust, while standard tape yellows and loses adhesion.
- Border-Marking Technique: When an attachment is mounted onto a page, the researcher must sign and date across the border so that the ink spans both the mounted slip and the notebook page. This confirms that the attachment was affixed on that date and has not been substituted.
Electronic Lab Notebook (ELN) Infrastructure
Laboratories transitioning to digital record-keeping must deploy validated systems rather than consumer note-taking applications. Distinguishing between laboratory information management systems and electronic notebooks is critical: while a LIMS manages sample batches and workflow logistics, an ELN captures experimental narratives, protocol executions, and observational data.
Compliant electronic platforms must implement technical controls mandated by 21 CFR Part 11 and EU Annex 11, including automated append-only audit trails, role-based access permissions, cryptographic timestamping, dual-factor electronic signatures, and automated off-site disaster backups. Standardizing structural templates across research teams through predefined electronic lab notebook templates ensures uniformity in data capture across projects.
Steps
Organizing a laboratory notebook requires systematic execution across the entire life cycle of an experiment, from initial setup to final corroboration. Follow these eight sequential steps to establish and maintain an auditable, reproducible research record.
Step 1: Set Up Front Matter and Table of Contents
Before recording experimental observations, configure the notebook navigation and administrative identity framework:
- Complete the Ownership Block: On the inside front cover, enter the laboratory or institutional name, department, principal investigator (PI), primary researcher name, project title, volume number, and emergency contact details. State clearly that the notebook is institutional property.
- Reserve Index Pages: Dedicate the first 3 to 6 pages exclusively for an expanding Table of Contents (TOC). Do not write experimental notes on these pages.
- Format the TOC Columns: Divide each TOC page into distinct columns: Date (YYYY-MM-DD), Experiment ID, Descriptive Subject Title, Project Code, Notebook Page Range, and Reviewer Sign-Off Date.
- Maintain Real-Time Indexing: Update the Table of Contents concurrently as each entry is completed; a blank TOC creates an audit vulnerability during inspections or patent reviews.
Step 2: Initialize Entry Header and Metadata
Every experiment must begin on a clean page. If an experiment spans multiple pages, each subsequent page must carry the experiment identifier and a reference back to the preceding page:
- Assign a Unique Experiment Identifier: Use an institutional alphanumeric taxonomy, such as
EXP-2026-042or[ResearcherInitials]-[ProjectCode]-[EntryIndex]. - Record the Date in Standardized Format: Write the date using the ISO 8601 international standard (YYYY-MM-DD, e.g., 2026-11-15) to eliminate ambiguity between day-first and month-first notations.
- Formulate a Descriptive Title: State a precise title reflecting the specific experimental objective (e.g., “Kinetics of Beta-Glucosidase Variant B3 Hydrolysis of pNPG at pH 5.5”) rather than generic labels like “Enzyme Run 4”.
Step 3: Define Objective, Theoretical Rationale, and Hypothesis
Document the scientific purpose before commencing bench manipulations:
- Statement of Purpose: Write a concise paragraph explaining why the experiment is being conducted and what question it addresses.
- Testable Hypothesis: Formulate an explicit, falsifiable hypothesis (e.g., “Substitution of Glu142 with Asp will reduce catalytic efficiency kcat/Km by at least twofold due to altered active-site carboxylate positioning”).
- Background and Protocol Citations: Cite relevant literature references, published papers, or internal Standard Operating Procedures (SOPs) with exact version numbers (e.g., “Conducted per SOP-BIO-088 v3.2”).
Step 4: Itemize Materials, Reagents, and Equipment Traceability
To ensure experimental reproducibility, record the complete lineage of consumables and instrumentation:
- Reagents and Solutions: List every chemical, buffer, biological specimen, and cell line used. Include manufacturer name, catalog number, batch or lot number, purity grade, preparation date, and expiration date.
- Working Solution Recipes: Detail exact mass, volume, and molarity calculations for custom buffers, including solvent lot numbers and measured pH values after temperature equilibration.
- Instrument Calibration and Settings: Record specific instrument asset tags (e.g., Analytical Balance BAL-04, Spectrophotometer SPEC-02), current calibration status, calibration check readings (e.g., 100.00 mg reference weight reading 100.01 mg), operating parameters, and software firmware versions.
Step 5: Document Procedural Execution and Protocol Deviations Contemporaneously
Record observations at the bench in real time as events occur, never reconstructing steps from memory hours later:
- Chronological Bench Logging: Record exact addition times, mixing durations, centrifuge speeds (in relative centrifugal force × g, not just RPM), and ambient laboratory temperatures.
- Log Unexpected Occurrences: Document transient phenomena such as color changes, turbidity, precipitation, foaming, or temperature spikes. Negative or unexpected results are fully as valuable as anticipated findings.
- Record Protocol Deviations Promptly: If an unforeseen circumstance forces a variation from the intended SOP (e.g., incubation prolonged due to equipment maintenance), document the exact protocol deviation, its proximate cause, and its immediate observed effect on the reaction mixture.
Step 6: Capture Raw Observations, Calculations, and External Data Links
Organize primary data directly on the page without intermediate scratch-paper transcription:
- Direct Entry of Raw Data: Tabulate replicate readings, absorbances, weights, or cell counts directly into formatted tables on the page.
- Show Worked Calculations: Detail mathematical formulas, sample calculations, dilution factors, and statistical summaries (mean, standard deviation, coefficient of variation). Do not present only final computed values.
- Link External Digital Datasets: For large automated datasets (such as sequencing runs, flow cytometry files, or NMR spectra), record the exact digital repository pathway, accession number, instrument run identifier, and cryptographic checksum (SHA-256 hash). This establishes a traceable link between the notebook narrative and external digital files.
Step 7: Formulate Results Summary, Discussion, and Immediate Next Steps
Analyze experimental findings while operational details remain fresh:
- Summarize Findings: State key quantitative conclusions (e.g., “Variant B3 exhibited a Km of 1.48 ± 0.09 mM, representing a 2.18-fold increase in Km relative to wild-type”).
- Hypothesis Assessment: Explicitly state whether the recorded data support, refute, or leave unresolved the initial hypothesis.
- Actionable Next Steps: Outline immediate follow-up investigations (e.g., “Repeat assay with inhibitor series KI-101 at concentrations ranging from 0.1 to 50 µM”).
Step 8: Execute Closeout, Cross-Out Unused Space, and Secure Witness Corroboration
Conclude the entry with protective closeout procedures:
- Cross Out Remaining Blank Space: Draw a clean diagonal line across any unused space on the page, accompanied by your initials and the date. This prevents subsequent additions or unauthorized backdated insertions.
- Author Sign-Off: Sign and date the bottom of the page upon completion of the entry.
- Obtain Timely Witness Corroboration: Have the entry reviewed, signed, and dated by a technically qualified colleague who has read and understood the work. To satisfy United States Patent and Trademark Office (USPTO) evidentiary standards under MPEP § 2138.05 and GLP study requirements, the witness must not be a direct co-worker or co-inventor on the specific project. Witnessing should occur within two weeks of entry completion.
What can go wrong
Even experienced researchers encounter documentation pitfalls that compromise research validity, trigger regulatory audit citations, or weaken patent filings. Recognizing and preventing these failure modes is critical for laboratory operational integrity.
Retrospective Logging and Backdating
Writing entries days after experimental work, reconstructing procedures from memory, or transcribing observations from informal scrap paper onto official pages violates the foundational “Contemporaneous” requirement of Good Documentation Practices. During an audit, discrepancies between automated instrument electronic timestamps and handwritten notebook dates reveal retrospective recording, resulting in immediate invalidation of study data.
Destructive Error Correction (White-Out and Obliteration)
Using correction fluid, adhesive labels, erasers, or heavy scribbles to conceal mistakes is one of the most critical regulatory violations in laboratory record-keeping. Under FDA 21 CFR § 58.130(e), any alteration that obscures the original entry triggers immediate suspicion of data manipulation or fraud. The only legally acceptable error-correction procedure is the single-line strike-through: draw one horizontal line through the incorrect text (ensuring the original characters remain completely legible), enter the correct data adjacent to the strike-through, record the date, write your initials, and provide a standard reason code (e.g., “EE” for Entry Error or “CE” for Calculation Error).
Excised Leaves and Unaccounted Page Gaps
Tearing out a spoiled, spilled-on, or poorly written page destroys the physical continuity of the notebook. Because leaves in a compliant notebook are consecutively numbered, any missing page indicates potential concealment of adverse findings. If a spill occurs or an experiment is aborted, retain the page, draw a large diagonal cross across it, write “ABORTED” or “SPILL – REPEATED ON PAGE X”, initial, and date the annotation.
Orphan Data and Broken External Digital Linkages
In modern hybrid laboratories, analytical instruments output gigabytes of raw data stored on local hard drives or network shares. If the notebook merely notes “data saved on instrument PC” without specifying the precise directory path, filename convention, software version, and digital hash, the data become orphan records. Over time, instrument hard drives are reformatted or replaced, rendering the handwritten notebook entry uninterpretable and unrepeatable.
Missing Reagent Lot Numbers and Calibration Logs
Documenting a protocol without capturing reagent lot numbers and expiration dates eliminates the ability to troubleshoot subsequent experimental anomalies. When an assay fails due to reagent degradation, batch-to-batch antibody variation, or an uncalibrated micropipette, the lack of traceable lot identifiers forces researchers to discard weeks of experimental work.
Untimely or Incompetent Witnessing
Accumulating months of unreviewed notebook pages before requesting a mass sign-off undermines the legal evidentiary value of witness corroboration. Furthermore, having a non-technical administrator or a direct co-inventor sign as witness renders the corroboration defective during patent priority challenges under USPTO rules.
When to get professional help
While routine experimental documentation is managed directly by laboratory personnel, certain regulatory, legal, and operational events require immediate escalation to specialized institutional offices and professional compliance advisors.
Quality Assurance (QA) and Study Director Escalation
Consult your facility’s Quality Assurance Unit (QAU) or designated GLP Study Director under the following conditions:
- When initiating formal nonclinical safety studies, preclinical pharmacokinetic trials, or toxicology evaluations regulated under FDA 21 CFR Part 58 or EPA GLP standards.
- When a critical protocol deviation or equipment failure occurs that compromises study data integrity, requiring a formal corrective and preventive action (CAPA) investigation.
- Prior to hosting external regulatory inspections by the FDA, EPA, or accredited sponsorship bodies.
Technology Transfer and Intellectual Property (IP) Counsel
Engage institutional technology licensing officers or registered patent attorneys immediately when:
- An experimental entry establishes an unexpected breakthrough, novel chemical entity, or commercially viable method that represents potential patentable subject matter.
- Public presentation (such as a conference abstract, poster, or preprint publication) is imminent, necessitating an urgent patent filing to preserve international novelty rights under the America Invents Act (AIA).
- Inventorship disputes arise regarding conception dates, requiring formal corroboration audits of laboratory notebooks under USPTO MPEP § 2138.05 standards.
Research Integrity Officers (RIO) and Institutional Compliance
Contact your institution’s Research Integrity Office or Office of Academic Affairs if:
- There is any suspicion or allegation of deliberate data falsification, fabrication, or record alteration.
- Physical laboratory notebooks are lost, stolen, or structurally damaged by fire, flood, or chemical spills.
- A departing researcher claims personal ownership of original notebooks or refuses to transfer primary records to the Principal Investigator, triggering institutional research data ownership policy enforcement.
Environmental Health and Safety (EHS) and Radiation Safety
Collaborate with EHS safety specialists whenever laboratory record-keeping involves statutory compliance logs for radioactive isotope inventories, DEA controlled substances, hazardous waste disposal manifests, or select biological agents requiring specialized chain-of-custody logging.
Worked example: compliant notebook entry walkthrough
The following annotated entry illustrates a compliant laboratory notebook record adhering to Good Documentation Practices, FDA 21 CFR § 58.130 guidelines, and ALCOA+ data integrity standards.
PAGE: 42
DATE: 2026-11-15
INVESTIGATOR: Dr. Julian Mercer | PROJECT: PRJ-ENZ-GLU | NOTEBOOK VOL: 03
TITLE: Michaelis-Menten Kinetic Analysis of Recombinant Beta-Glucosidase Variant B3
1. OBJECTIVE AND HYPOTHESIS:
Determine kinetic constants (Km and Vmax) for recombinant B. subtilis beta-glucosidase variant B3 (E142D) using p-nitrophenyl-beta-D-glucopyranoside (pNPG) substrate at pH 6.0, 37°C. Hypothesis: The E142D carboxylate relocation will increase Km toward pNPG by more than 1.5-fold relative to wild-type (WT baseline Km = 0.68 mM).
2. MATERIALS AND INSTRUMENTATION:
– Enzyme: Variant B3 purified stock, Lot # B3-20261102, Conc: 1.24 mg/mL (BCA assay, p. 38), stored -80°C.
– Substrate: pNPG (Sigma-Aldrich, Cat # N7006, Lot # SLCC4912, Exp: 2027-04), 50 mM stock in Assay Buffer.
– Assay Buffer: 50 mM Sodium Phosphate, 100 mM NaCl, pH 6.00 at 25°C (Prep log p. 40).
– Stop Solution: 1.0 M Sodium Carbonate (Na2CO3), Lot # SC-260901.
– Instruments: Analytical Balance BAL-04 (Cal check: 100.00 mg std reads 100.01 mg, passed). Micropipettes PIP-01, PIP-04 (Calibrated 2026-10-12). Spectrophotometer SPEC-02 (Shimadzu UV-1800, Wavelength 405 nm, Path length 1.0 cm).
3. PROCEDURE AND CONTEMPORANEOUS OBSERVATIONS:
– 09:15 EST: Thawed Enzyme Lot # B3-20261102 on wet ice. Diluted 1:50 in ice-cold Assay Buffer (final conc: 24.8 µg/mL).
– 09:30 EST: Prepared 8 substrate dilutions in duplicate (0.1, 0.25, 0.5, 1.0, 2.0, 4.0, 8.0, 16.0 mM pNPG).
– 09:45 EST: Equilibrated reaction tubes in 37.0°C circulating water bath for 10 min.
– 09:55 EST: Initiated reactions by adding 50 µL enzyme dilution to 450 µL substrate mixture at 30-sec staggered intervals.
– 10:15 EST: Terminated reactions after exactly 20.0 min by adding 500 µL 1.0 M Na2CO3. Intense yellow coloration observed immediately at higher substrate concentrations (exceeding 2.0 mM). No precipitation detected.
4. ERROR CORRECTION DEMONSTRATION:
Tube 6 (4.0 mM) duplicate A was initially dosed with 45 µL 50 µL enzyme stock [JM 2026-11-15 EE: Corrected volume adjustment to match SOP].
5. RAW OBSERVATIONAL DATA AND EXTERNAL DATA LINKAGE:
Absorbance at 405 nm measured against reagent blank (Zeroed at A405 = 0.000):
[S] (mM) | A405 (Rep 1) | A405 (Rep 2) | Mean A405 | Net Velocity (µmol/min/mg)
0.10 | 0.078 | 0.082 | 0.080 | 0.14
0.50 | 0.298 | 0.304 | 0.301 | 0.54
1.00 | 0.485 | 0.491 | 0.488 | 0.88
2.00 | 0.690 | 0.698 | 0.694 | 1.25
4.00 | 0.885 | 0.891 | 0.888 | 1.60
8.00 | 1.042 | 1.050 | 1.046 | 1.88
16.00 | 1.135 | 1.141 | 1.138 | 2.05
Digital Raw Data Archive: /data/spectroscopy/2026/EXP-2026-084_uvspec_raw.csv
File SHA-256 Hash: e3b0c44298fc1c149afbf4c8996fb92427ae41e4649b934ca495991b7852b855
6. CALCULATIONS AND RESULTS:
Nonlinear regression to Michaelis-Menten model executed in R (Script: analyze_kinetics_v2.R):
– Vmax = 2.41 ± 0.06 µmol/min/mg protein
– Km = 1.48 ± 0.09 mM (R² = 0.996)
Relative to WT (Km = 0.68 mM), variant B3 exhibits a 2.18-fold increase in Km, supporting the hypothesis that E142D perturbs substrate coordination.
— [DIAGONAL LINE STRUCK THROUGH REMAINING UNUSED PAGE SPACE] JM 2026-11-15 —
INVESTIGATOR SIGNATURE: Julian Mercer, Ph.D.
DATE: 2026-11-15
READ AND UNDERSTOOD BY: Dr. Elena Rostova
WITNESS SIGNATURE: Elena Rostova
DATE: 2026-11-16
Frequently asked questions
Can I use pencil or erasable pen in a lab notebook?
No. Using pencil, erasable ink, or non-permanent writing media is strictly prohibited under Good Documentation Practices and FDA 21 CFR § 58.130(e). Entries must be recorded permanently in dark blue or black indelible pigment ink that resists water, light, and solvent degradation. Pencil entries can be erased, altered, or smudged over time, compromising the legal evidentiary standing and regulatory validity of the research record.
How should I correct a mistake in a laboratory notebook?
Never use correction fluid, white-out tape, erasers, or heavy scribbles to conceal mistakes. To correct an erroneous entry, draw a single horizontal line through the incorrect text so that the original characters remain fully readable. Write the correct information immediately adjacent to the strike-through, record the date of the correction, sign or initial the change, and provide a brief explanation or standard reason code (such as “EE” for entry error or “CE” for calculation error).
What should I do with blank space at the bottom of a page?
Any substantial blank space remaining at the bottom of a completed notebook page must be decommissioned to prevent retroactive additions. Draw a clean diagonal line across the unused area from the last line of text to the bottom corner of the page, sign or initial along the diagonal line, and write the current date. This practice provides physical proof that no subsequent data were inserted after the original sign-off.
Who can legally witness and countersign a lab notebook page?
Under United States Patent and Trademark Office (USPTO) corroboration rules (MPEP § 2138.05) and regulatory quality standards, a witness must be an individual with sufficient scientific background to understand the experimental work, but who is not a co-inventor or direct collaborator on the specific project. A witness must independently read and comprehend the entry before signing the “Read and understood by” statement and dating the page contemporaneously.
How should external digital data files be linked to a physical notebook?
For large digital datasets generated by analytical equipment (such as sequencing runs, mass spectrometry files, or high-content imaging archives), the physical notebook entry must explicitly record the exact digital repository pathway, the unique instrument run identifier, the software version used for data acquisition, and a cryptographic checksum (such as a SHA-256 hash). Recording the file hash guarantees that the digital raw data cannot be modified or replaced without detection, preserving end-to-end data integrity.
Who owns the lab notebook when a researcher leaves an institution?
Laboratory notebooks and raw experimental data are the legal property of the research institution or corporate entity where the work was performed, not the personal property of the individual researcher or postdoctoral fellow. When departing an institution, researchers must leave all original notebooks, primary data archives, and physical records with the Principal Investigator or departmental repository. Departing personnel may only retain copies of notebook records with explicit written institutional authorization.
Sources
- National Institutes of Health (NIH) — Intramural Research Program: Guidelines for Scientific Record Keeping in the Intramural Research Program at the NIH (Accessed 2026-11-15)
- U.S. Food and Drug Administration (FDA): 21 CFR § 58.130 – Good Laboratory Practice for Nonclinical Laboratory Studies: Conduct of a nonclinical laboratory study (Accessed 2026-11-15)
- United States Patent and Trademark Office (USPTO): Manual of Patent Examining Procedure (MPEP) § 2138.05: Reduction to Practice and Corroboration (Accessed 2026-11-15)
- Harvard Medical School — Office for Academic and Research Integrity: Guidelines for Research Records and Data Management (Accessed 2026-11-15)
- World Health Organization (WHO): Technical Report Series No. 996, Annex 5: Guidance on Good Data and Record Management Practices (Accessed 2026-11-15)
- CDC / National Institute for Occupational Safety and Health (NIOSH): Manual of Analytical Methods (NMAM), 5th Edition: Quality Assurance and Recordkeeping Standards (Accessed 2026-11-15)
Data: Laboratory Record-Keeping Modalities and Compliance Comparison
Comparative matrix evaluating laboratory record-keeping modalities across regulatory audit trails, ALCOA+ data integrity, tamper evidence, disaster recovery, and operational overhead, compiled from FDA 21 CFR 58/11 and USP standards.
Period covered: 2024/2026. Coverage: International.
| Modality | Audit Trail Mechanism | ALCOA+ Attributability | Tamper Evidence Level | Disaster Recovery | Annual Overhead per Bench (USD) | Regulatory Framework |
|---|---|---|---|---|---|---|
| Permanently Bound Hardcover Paper | Handwritten strike-through with date, initials, and reason code per 21 CFR 58.130(e) | Manual handwritten signatures and dates on every page by author and witness | Smyth-sewn permanent binding with sequential pre-numbered pages | Requires off-site climate-controlled fireproof physical vault storage | 45 | FDA 21 CFR Part 58, USP |
| Hybrid Bound Paper with Digital Mounts | Physical strike-through on page combined with instrument software event logs | Physical author signatures on page with cryptographic hashes for digital raw files | Bound page continuity; vulnerable to adhesive degradation or thermal paper fading | Physical notebook vault storage plus secondary network digital backup | 120 | FDA 21 CFR Part 58, EPA 40 CFR 160 |
| Validated On-Premises Electronic Lab Notebook | System automated append-only audit trail with secure cryptographic timestamps | Dual-factor electronic signatures tied to individual directory credentials | Database immutability, cryptographic checksums, and version tracking | Enterprise local RAID storage with scheduled off-site tape replication | 450 | FDA 21 CFR Part 11, EU Annex 11 |
| Validated Multi-Tenant Cloud ELN | Automated continuous cloud audit trail with immutable write-once logs | SSO/SAML 2.0 dual-factor authentication and PKI digital signing keys | SOC 2 Type II controls, AWS/Azure immutable object storage, TLS encryption | Geo-redundant multi-region cloud replication and automated hot failover | 680 | FDA 21 CFR Part 11, ISO/IEC 27001 |
Sources
- FDA 21 CFR Part 58 - Good Laboratory Practice for Nonclinical Laboratory Studies (accessed 2026-11-15)
- FDA 21 CFR Part 11 - Electronic Records; Electronic Signatures (accessed 2026-11-15)
- USP General Chapter Good Documentation Practices (accessed 2026-11-15)
- NIH Guidelines for Scientific Record Keeping in the Intramural Research Program (accessed 2026-11-15)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.