Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
General product-use information from manufacturer instructions, not medical advice. For how your clinic weighs and records patients, follow its own procedure.
To read a doctor’s scale (a mechanical beam scale with sliding weights, called poises), balance the pointer in the middle of its opening, read the number beside the arrow on each poise bar, and add the two readings together. Pounds are on the upper part of each bar and kilograms on the lower part. This page follows the manufacturer’s user instructions for one common model; your scale’s own manual governs if it differs.
This page is a read-it-at-the-scale walkthrough. For beam parts, capacity and specification detail, see the physician scale guide; patient scales for people who cannot stand are covered in what is a bed scale, and infant weighing is a separate class in the infant scale guide.
Which kind of scale am I reading?
How to read a doctor scale or medical scale: beam versus digital
A beam scale has a pointer inside a small opening (the trig-loop) and two sliding weights on graduated bars. A digital scale shows the weight on a display and is read according to its own manual; the physician scale guide has a certified digital example. The steps below apply to the beam type. Infant scales and bed scales are different equipment with their own instructions.
What you need
- A mechanical beam scale with its height rod, standing on a hard, flat, level surface.
- The scale’s user manual, for its weight limit and any model differences. The Henry Schein 112-7157 model, for example, states a limit of 450 lb / 210 kg.
- A second person to assist the person being weighed on and off the platform.
Steps: how to read a medical scale (beam type)
- Check the zero. Put both poises on “0”. The pointer should float gently up and down without touching the top or bottom of the trig-loop. If it is not centred, the manufacturer says to rotate the balance ball screw at the left end of the bar with a flat-head screwdriver. Check periodically, and especially after the scale has been moved.
- Set the poises to an approximate weight. Place the large and small poises near the expected weight.
- Weigh. With the person standing on the platform, move the small and large poises until the pointer is centred. The pointer does not have to stop moving: the manufacturer states that as long as it moves equally within the opening, the weight can be determined.
- Read each bar. On each poise bar, read the value closest to the indicator arrow built into that poise.
- Identify the unit. Pounds (lb) are silver graduations on a black background on the upper part of each bar. Kilograms (kg) are black graduations on a silver background on the lower part. The weight can be recorded in either.
- Add the two readings. The small-poise reading plus the large-poise reading is the weight.
Worked example from the manufacturer
| Poise | Reading (lb) |
|---|---|
| Lower (large) poise | 400 |
| Small poise | 41 |
| Weight | 441 |
The manufacturer’s own example: a person who weighs 441 lb has the lower poise at 400 lb and the small poise at 41 lb, so 400 + 41 = 441 lb.
Reading the height rod
Raise the headpiece above the head, position the person against the rod with upright posture and the head straight and level, then push the headpiece down until it rests on the head. Height is the value on the measuring strip nearest the line on the indicator. The manufacturer states the person needs to be at least 23 5/8 in (600 mm) tall for height to be measured accurately. Detecto’s manual labels this reference line “Read”.
What can go wrong
- Pointer will not centre with both poises at “0”. Make sure both poises are firmly against the shoulder of the beam, then adjust the balance ball screw.
- Pointer touches the side of the trig-loop. The bar is not moving freely; the manufacturer says realignment of the beam may be necessary.
- The beam does not move at all. The steel rod connection may be improper, or a poise may be set higher than the actual weight. Reset to a lower weight.
- The platform rocks or touches the base at a corner. The base is out of alignment; contact technical support.
- Wrong unit. The upper (lb) and lower (kg) graduations sit on the same bars, so check the background colour of the scale you are reading before you record a unit.
When to get professional help
Do not use a damaged scale until a qualified service agent has serviced it. Henry Schein recommends service by a qualified service lab every 3 to 5 years, depending on frequency of use. Detecto’s warning is that an attendant must assist the patient on and off the platform and never leave the patient unattended on it, as losing control can cause serious injury. For wider office equipment context, see medical supplies for a doctor’s office.
FAQ
How do I read a doctor scale?
Centre the pointer by moving the two poises, read the value beside the arrow on each poise bar, and add them. The manufacturer’s example is 400 lb + 41 lb = 441 lb.
How do I read a medical scale in kilograms?
Use the lower graduations on each poise bar: black numbers on a silver background. Add the two kilogram readings the same way.
Is there a doctor weight scale chart?
A beam scale has no lookup chart; the graduations on the two poise bars are the scale. The worked table above shows how the two readings combine.
Does the pointer have to stop moving?
No. The manufacturer states it only has to move equally within the trig-loop opening.
How do I read height on the scale?
Lower the headpiece onto the head and read the measuring strip value nearest the indicator line.
Sources
- Henry Schein, Mechanical Beam Scale with Height Rod, item 112-7157, user instructions: https://www.henryschein.com/assets/Medical/HS1127157.pdf (checked 2026-11-01).
- Detecto (Cardinal Scale), Physician’s Eye-Level Beam Scale Operation Instructions, document 8525-M063-O1 Rev M, 10/15, retailer-hosted copy: https://tigermedical.com/cdn/shop/files/DET437–20200131231741746.pdf (checked 2026-11-01).