Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
“iPSC exosomes” is the common bench shorthand for small extracellular vesicles (EVs) released by induced pluripotent stem cells (iPSCs) or by cells differentiated from them, such as iPSC-derived mesenchymal stromal cells. The International Society for Extracellular Vesicles (ISEV) discourages the word “exosome” unless the vesicle’s subcellular origin has been demonstrated, so most methods sections should use the generic term “EV” (ISEV’s recommended term), and may add “small EV” only as an operational term with a stated size range, used with caution, and describe the culture medium, collection window and isolation method used. The evidence for therapeutic use is still mostly preclinical.
Definition and scope: exosome, small EV and EV
Extracellular vesicles are lipid-bilayer particles released by cells. Cells that are pluripotent, grown in defined culture and able to proliferate for long periods are attractive producers, which is why iPSCs are used both as a direct source of vesicles and as a starting population for differentiated cells that are then used as vesicle producers. The first of those routes gives iPSC-EVs; the second gives, for example, iPSC-derived mesenchymal stromal cell EVs (iMSC-EVs). The two should not be merged in a paper or a protocol, because the producing cell differs.
Why the term “exosome” is discouraged
The ISEV position statement known as MISEV2023 (Welsh et al., Journal of Extracellular Vesicles 2024;13(2):e12404) favors the generic term “EV” over names tied to biogenesis. It states that biogenesis terms are “discouraged unless subcellular origin can be demonstrated”, and that “sEV” (small EV) and “exosome” are “not synonymous”. The same guidance notes that there is “no strict consensus on upper and lower size cut-offs” for small EVs. A size range alone therefore does not establish that a preparation is exosomes in the strict sense.
The practical consequence for a lab is a wording rule. Write what you did and measured (for example, “small EVs isolated from hiPSC conditioned medium by tangential flow filtration, characterized by nanoparticle tracking analysis”) rather than “exosomes”. Vendor product names and search terms still use “exosome”, which is why this page carries the keyword, but a manuscript or SOP that follows MISEV2023 should not.
How iPSC EVs are produced and used in practice
A non-systematic review of 36 studies on human pluripotent stem cell-derived EVs (Matos et al., World Journal of Stem Cells 2023;15(5):453-465) gives the clearest picture of what labs actually do. The points below are what that review reports, not a recommended protocol.
Culture conditions and conditioned medium
- Media. The most common media in the reviewed studies were the commercial defined media mTeSR1 and Essential 8.
- Collection window. Conditioned medium was usually collected at 24 hours or daily for 3 to 5 days, and collection typically took place at roughly 80-90% confluence; the review notes the cells must not reach 100% confluence. Many studies did not report the timing at all.
- Serum replacement. One study used EV-depleted KnockOut Serum Replacement at 0.5% to 20%; cells stayed viable at 0.5%, but some pluripotency markers fell after 5 days of culture. Another used exosome-depleted fetal bovine serum.
- Oxygen. One study compared 1% oxygen, 5% oxygen and normoxia, and reported that EVs from hypoxic cultures had greater angiogenic potential.
Why the medium itself matters
MISEV2023 states that cell culture conditions “directly and indirectly affect EV yield, composition, and function”. Medium components can contain EVs or can be taken up by cells and repackaged into EVs, and commercial “EV-free” products “should also not be assumed to be devoid of EVs without verification”. The guidance also warns that EVs released by only a few percent of dying cells may outnumber those from healthy cells, which is one reason culture health and collection timing belong in the record. The guidance asks authors to report the medium composition and how it was prepared; where serum is depleted, to report the method and degree of depletion; to process and characterize non-conditioned medium controls; to check and report mycoplasma contamination; and to remove cells from the conditioned medium as early as possible.
Isolation
Differential centrifugation followed by ultracentrifugation was the most common route in the review, sometimes with 0.22 µm filtration, with commercial precipitation or capture kits, size-exclusion chromatography (SEC) and tangential flow filtration (TFF) as alternatives. The authors judge differential centrifugation plus ultracentrifugation “unsuitable for isolating EVs from large-scale experiments and clinical trials”. Background reading on the techniques is on this site: ultracentrifugation, tangential flow filtration and the supernatant versus pellet comparison, which helps when deciding what to keep after a spin.
The dataset on this page sets the isolation routes side by side. Two of its points are worth stating in words. First, in a large-scale 2D culture comparison cited by the review, TFF with or without ultracentrifugation gave EVs of about 100 nm, but adding ultracentrifugation resulted in fewer proteins. Second, the review reports the better angiogenic results when EVs were obtained using TFF.
Characterization
Across the 36 studies, western blot and transmission electron microscopy were each used in 31 and nanoparticle tracking analysis in 20; most preparations were small EVs under 200 nm, with reported mean sizes spanning roughly 30 to 400 nm, and the methods followed the earlier MISEV2018 guidance. For the sizing technique, see nanoparticle tracking analysis. The review does not give a marker panel, and this page does not either; take the current marker and purity requirements directly from MISEV2023.
Types: iPSC-EVs, iMSC-EVs and extruded nanovesicles
Three product types are easy to confuse because all are loosely called “iPSC exosomes”.
EVs from undifferentiated iPSCs
These are released into the conditioned medium by pluripotent cultures. The Matos review says production of human iPSC EVs was about 16-fold higher than that of mesenchymal stromal cell (MSC) EVs in the same medium in one study, and ties the production advantage to the cells’ unlimited proliferation. It also states that large-scale culture can be expensive and that results across studies are highly variable. Cargo profiling is limited, and the iPSC EVs appear less enriched in immune-regulation proteins than MSC EVs. The authors conclude that pluripotent stem cell EVs have not been shown to outperform other EVs.
EVs from iPSC-derived mesenchymal stromal cells
Bertolino and colleagues (Biomedicines 2022;10(9):2281) review EVs from iMSCs. They report that iMSC-EVs resemble tissue-derived MSC-EVs in size (50-200 nm), production rate, ultrastructure and proteome, and that MSCs from a single iPSC clone are more homogeneous than primary MSCs from tissue, since iPSCs can be expanded before differentiation. They also state that no consensus method has been chosen for GMP-compliant scale-up of iMSCs, and that serial TFF filtration is attractive and GMP-compatible. Reported risks include co-isolated virus or endotoxin, the need to show that reprogramming factors are absent from the iMSCs and their EV cargo, and weaker T-cell suppression and trilineage differentiation in iMSCs than in bone-marrow MSCs. The data they describe are mostly preclinical, and they call for large animal models.
Cell-engineered nanovesicles
Vesicles made by passing cells through serial extrusion are not secreted EVs. The Matos review discusses them separately and reports a higher production yield than pluripotent stem cell EVs without giving numbers. Call them nanovesicles, not exosomes or EVs, in methods text.
Where it matters for labs, clinics and supply decisions
A reporting checklist built from the sources
The items below combine the MISEV2023 reporting expectations with what the 36-study review shows was often left out. They describe what to record, not how to run a procedure.
- The producing cell type: undifferentiated iPSCs, a named differentiated lineage, or extruded nanovesicles.
- Medium composition and preparation, and the depletion method and degree if serum or serum replacement was depleted of EVs.
- A processed and characterized non-conditioned medium control.
- Mycoplasma testing results.
- Collection timing and confluence at collection, which many reviewed studies did not report.
- Time from collection to removal of cells.
- Isolation route, including any filtration step, and the characterization methods used.
- The word used: “EV” or “small EV” unless origin was demonstrated.
Cell culture context for the producer lines is covered in the guide to iPSC cell culture, and the effect of media choice in the guide to types of cell culture media.
Scale and clinical translation
Both reviews place iPSC-derived EV work at the preclinical stage. The Matos authors note that GMP-compatible isolation needs development and that the teratoma risk raised for parent pluripotent cells is unresolved for their EVs. Bertolino and colleagues list the infection, endotoxin and reprogramming-factor risks above. Nothing here is medical advice, and no product described in these papers is established as a treatment.
Common misunderstandings
- “Exosome” and “small EV” mean the same thing. MISEV2023 says they are not synonymous.
- EV-free serum is EV-free. The guidance says commercial “EV-free” products should not be assumed free of EVs without verification.
- A size window proves identity. The guidance notes there is no strict consensus on size cut-offs.
- iPSC EVs are a proven improvement over MSC EVs. The Matos review reports higher production but no demonstrated performance advantage.
- iPSC EVs and iMSC EVs are one product. They come from different producer cells and carry different reported risks and advantages.
- More EVs means a healthier culture. The guidance notes that a few percent of dying cells can release more EVs than healthy cells.
Frequently asked questions
Are iPSC exosomes the same as iPSC-derived small EVs?
Not by ISEV’s definition. MISEV2023 says “sEV” and “exosome” are not synonymous and discourages biogenesis terms unless subcellular origin is shown, so a preparation of small vesicles from iPSC conditioned medium should be called small EVs.
Which isolation method do iPSC EV studies use most?
In the 36-study Matos review, differential centrifugation followed by ultracentrifugation was the most common, with precipitation kits, SEC and TFF as alternatives. The authors consider it unsuitable for large-scale work and clinical trials.
Do iPSC EVs differ from iMSC EVs?
Yes. iPSC EVs come from pluripotent cultures; iMSC EVs come from mesenchymal stromal cells differentiated from iPSCs. Bertolino and colleagues report that iMSC EVs resemble tissue MSC EVs in size, production, ultrastructure and proteome.
Can culture medium change the result?
Yes. MISEV2023 states that culture conditions affect EV yield, composition and function, and that medium components may contain EVs or be repackaged into EVs, so a non-conditioned medium control should be processed and characterized.
Are iPSC-derived EVs approved therapies?
The reviews cited here describe the work as preclinical and note unresolved safety and manufacturing questions. This page gives no individual medical advice.
Sources
- Welsh JA, Goberdhan DCI, O’Driscoll L, et al. Minimal information for studies of extracellular vesicles (MISEV2023). J Extracell Vesicles 2024;13(2):e12404. PubMed Central full text; DOI 10.1002/jev2.12404. Checked 2026-11-16.
- Matos BM, Stimamiglio MA, Correa A, Robert AW. Human pluripotent stem cell-derived extracellular vesicles: From now to the future. World J Stem Cells 2023;15(5):453-465. Full text at WJG Press. Checked 2026-11-16.
- Bertolino GM, Maumus M, Jorgensen C, Noel D. Recent advances in extracellular vesicle-based therapies using induced pluripotent stem cell-derived mesenchymal stromal cells. Biomedicines 2022;10(9):2281. PubMed Central full text. Checked 2026-11-16.
Data: Isolation routes for pluripotent stem cell-derived EVs as reported in a 36-study review
Compares the EV isolation routes named in a non-systematic review of 36 human pluripotent stem cell EV studies, with the example study, reported mean EV size and what the review states about each route. Compiled from the review's text and Table 1.
| Isolation route | Example study cited | Reported mean EV size (nm) | What the review states |
|---|---|---|---|
| Differential centrifugation plus ultracentrifugation | About 25 studies in Table 1 | not stated | Most common route; authors call it unsuitable for large-scale experiments and clinical trials |
| Tangential flow filtration, with or without ultracentrifugation | Andrade et al. | 100 | Similar particle concentration either way; adding ultracentrifugation gave fewer proteins; better angiogenic results with TFF |
| Concentration (100 kDa) plus size-exclusion chromatography | Liu et al. 2019 | 150 | Used for hiPSC-EVs whose production was about 16-fold higher than MSC-EVs in the same medium |
| Sucrose gradient | Ashok et al. 2021 | 50 | Listed in Table 1; no advantages or disadvantages stated |
| One-step sucrose cushion ultracentrifugation | Gupta et al. 2022 | 123.6 | Listed in Table 1 (mean size 123.6 nm, standard deviation 60 nm) |
| Commercial precipitation or capture kits | Several studies (e.g. Oh 2018; Luo 2021) | not stated | Named kits listed in Table 1; no advantages or disadvantages stated |
Sources
- Matos et al. Human pluripotent stem cell-derived extracellular vesicles: From now to the future. World J Stem Cells 2023 (accessed 2026-11-16)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.