Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop lane bone holding forceps supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

Lane Bone Holding Forceps: What They Are, How They Work and How They Are Classified

What Lane bone holding forceps are, how they are built, the lengths listed in FDA and MSF records, their FDA category and reprocessing basics.

Written and maintained by CASRAI Editorial Board

Published · Last updated

This page describes products and general use; it is not medical advice.

On this page

Lane bone holding forceps are a reusable, hand-held orthopaedic instrument that grips bone during fracture reduction and fixation. This page covers what the instrument is, how one catalogue describes its build, the lengths that two public records list, how its regulatory category works and the reprocessing basics, for clinic staff, buyers and students.

What are Lane bone holding forceps?

Lane bone holding forceps (also sold as a Lane bone holding clamp) are a two-bladed orthopaedic surgical instrument with a handle, used to grasp and compress bone. The Médecins Sans Frontières (MSF) Unicat catalogue defines the type as an instrument “for compressing or grasping tissues” that is used “to perform bone fracture reduction and fixation”. The FDA AccessGUDID device record for a Lane bone holding clamp with ratchet places it under the GMDN term “bone approximation clamp”: a hand-held manual surgical instrument that grips and holds a bone, or is used in pairs on either side of a fracture to approximate the two bone segments during orthopaedic surgery. That record states: “This is a reusable device.”

Who uses it: surgical teams performing orthopaedic fracture work, and the sterile processing and supply staff who prepare and stock the instrument.

How is it built?

The MSF Unicat entry for its 33 cm Lane bone holding forceps describes double jaws, square-shaped, with 2 x 2 teeth and horizontal serrations, and a plier-style handle with a bar ratchet at the bottom. One handle shank carries a hook projection where the operator can rest a hand. The listed material is martensitic steel. The GMDN definition in AccessGUDID says instruments of this term are typically made of high-grade stainless steel. The AccessGUDID record is for a “with ratchet” model.

What lengths are listed?

Source Item Listed length Other listed details
FDA AccessGUDID, record version dated 2026-03-05 Sontec Lane bone holding clamp with ratchet, catalogue 305-352 13 inches Reusable; not supplied sterile; sterilization required before use
MSF Unicat, code 35-61-33 Forceps, bone holding, Lane, 33 cm 33 cm (about 13 inches) Martensitic steel; classified “L091301 – Bone grasps, reusable”

The two records describe the same length in different units (33 cm converts to about 13 inches).

How is it classified by the FDA?

The US Code of Federal Regulations describes the orthopaedic manual surgical instrument category in 21 CFR 888.4540: a nonpowered hand-held device intended for medical purposes to manipulate tissue, including instruments used with other devices in orthopaedic surgery. The regulation sets Class I (general controls) and exempts the category from premarket notification, subject to the limits in 21 CFR 888.9. The regulation does not name Lane forceps, so a specific product’s category is set by the maker’s listing.

In AccessGUDID the Sontec record lists FDA product code HXD (CLAMP), marks the device as premarket exempt and as a prescription device, and lists it as not single-use. Product codes can differ between manufacturers of similar instruments.

Reprocessing and handling basics

The AccessGUDID record states that the device is not supplied sterile and requires sterilization before use, and lists dry heat and moist heat (steam) as sterilization methods. MSF classifies the item as a reusable bone grasp. For how sterile and non-sterile supplies differ when stocking a clinic, see the sterile vs non-sterile purchasing guide.

Frequently asked questions

Are Lane bone holding forceps reusable?

The AccessGUDID record for a Lane bone holding clamp with ratchet states “This is a reusable device”, and MSF classifies its 33 cm item as a reusable bone grasp.

Are they supplied sterile?

The AccessGUDID record says the device is not supplied sterile and requires sterilization before use, listing dry heat and moist heat (steam) as methods.

What lengths are listed?

The AccessGUDID record lists 13 inches and the MSF Unicat item lists 33 cm, which is about the same length.

What FDA class is the instrument category?

21 CFR 888.4540 places orthopaedic manual surgical instruments in Class I (general controls), exempt from premarket notification subject to 21 CFR 888.9.

Sources

  • FDA AccessGUDID, Lane Bone Holding Clamp with ratchet, device identifier 00192896027008, accessgudid.nlm.nih.gov, checked 2026-10-30.
  • eCFR, 21 CFR 888.4540 Orthopedic manual surgical instrument, ecfr.gov, checked 2026-10-30.
  • MSF Unicat, Forceps, bone holding, Lane, 33 cm (35-61-33), unicat.msf.org, checked 2026-10-30.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Lane Bone Holding Forceps: What They Are, How They Work and How They Are Classified

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →