Written and maintained by CASRAI Editorial Board
Published · Last updated
This page describes products and general use; it is not medical advice.
On this page
Magill forceps are angled, long-handled forceps used in anaesthesia and intubation to guide an endotracheal tube into the trachea or a gastric tube into the oesophagus. They are sold in child and adult lengths, and the length labelled “child” is not the same in every catalogue. This page sets out what the instrument is, how procurement catalogues describe it, how the sizes compare across two catalogues, and how it is classified by the US FDA.
What Magill forceps are
Magill forceps are a hand-held surgical instrument whose job is to guide a tube. The International Federation of Red Cross and Red Crescent Societies (IFRC) Standard Products Catalogue lists the item as “Forceps, catheter introducing, Magill” and states its purpose as guiding an endotracheal tube into the trachea or a gastric tube into the oesophagus, for intubation and anaesthesia. The same instrument is also called intubation forceps; Médecins Sans Frontières (MSF) classifies it in its catalogue as “Intubation forceps, reusable”.
Where they appear: the IFRC entry places the instrument under intubation and anaesthesia supplies, and the MSF catalogue lists it among its medical items.
How Magill forceps are built
The IFRC specification describes the instrument as “forceps with two non-detachable legs curved through an angle of about 30 degrees, ending in loops”. The inside of each loop (the spatula) is ribbed. The same specification gives the material as stainless steel, grade 2, lists the item as not sterile, specifies no sterilisation method, and says each unit is packed individually in a protective plastic bag.
- Two non-detachable legs: the instrument is one piece, not a take-apart design.
- Angle of about 30 degrees: the curve is built into the legs.
- Loop ends with ribbed inner faces: the ribbing is on the inside of each loop.
- Stainless steel, grade 2, supplied not sterile in the IFRC listing.
Types and sizes
Both catalogues sell the same instrument in child and adult lengths. The table shows exactly what each catalogue lists; each row comes from the catalogue named in it.
| Catalogue | Item as listed | Length | Notes from the listing |
|---|---|---|---|
| IFRC | Child, extra small (XSINMEDI457501) | 16 cm | Stainless steel, grade 2; not sterile |
| IFRC | Child, small (XSINMEDI457502) | 19 cm | Stainless steel, grade 2; not sterile |
| IFRC | Adult (XSINMEDI457503) | 24 cm | Stainless steel, grade 2; not sterile |
| MSF | Forceps, Magill, adult (product 12500) | 24 cm | Classified “Intubation forceps, reusable” |
The two catalogues agree on the adult length, 24 cm. IFRC lists two child sizes (16 cm and 19 cm). MSF also lists a paediatric item, product 12501, but this page does not rely on its length. The practical point is that a size word such as “child” or “paediatric” does not by itself fix a length: confirm the stated length in centimetres on the item you are comparing.
Regulatory classification in the United States
The FDA’s product classification database lists the device type “Forceps, Tube Introduction” under product code BWB, regulation number 21 CFR 868.5780, in the Anesthesiology panel, as a Class 1 device. A device named “MAGILL FORCEPS” was cleared through a traditional 510(k) (number K880319, applicant Eastmed Enterprises, Inc.) with a decision of “Substantially Equivalent” dated 21 March 1988.
For general background on how devices are defined and regulated, see what is a medical device.
Reusable and disposable
The MSF catalogue classifies its adult Magill forceps as reusable. The IFRC listing is for a stainless steel instrument supplied not sterile, with no sterilisation method specified. Whether and how a specific instrument is reprocessed is set by its manufacturer’s instructions for use and the facility’s own policy, not by this page. For background on sterilisation choices, see low-temperature sterilization method selection.
How to compare listings
The catalogue entries cited here state these criteria, which are the ones worth checking on any listing:
- The length in centimetres, because catalogues differ on what “child” means (IFRC 16 and 19 cm; MSF paediatric item listed separately).
- The material (the IFRC listing states stainless steel, grade 2).
- Sterile or not sterile as supplied (the IFRC listing states not sterile).
- Reusable or single-use classification (the MSF catalogue states reusable).
For other forceps and related instruments, see medical forceps types and ENT surgical instruments.
Common mistakes
- Treating “child” or “paediatric” as a standard length. The catalogues above list different child lengths.
- Assuming the instrument arrives sterile. The IFRC listing states not sterile.
- Treating Magill forceps as generic forceps. The IFRC specification defines a particular geometry: about 30 degrees, non-detachable legs and ribbed loop ends.
FAQ
What are Magill forceps used for?
To guide an endotracheal tube into the trachea or a gastric tube into the oesophagus during intubation and anaesthesia, according to the IFRC catalogue entry.
What are Magill forceps made of?
The IFRC listing gives stainless steel, grade 2.
What sizes do Magill forceps come in?
IFRC lists 16 cm, 19 cm (child) and 24 cm (adult); MSF lists a 24 cm adult item and a separate paediatric item.
Are Magill forceps reusable?
MSF classifies its adult item as reusable. Follow the manufacturer’s instructions for use for any specific product.
Are they regulated by the FDA?
Yes. “Forceps, Tube Introduction” is Class 1 under 21 CFR 868.5780, product code BWB.
Sources
- IFRC Standard Products Catalogue, “Forceps, catheter introducing, Magill” (last updated 31 December 2018), checked 1 November 2026: itemscatalogue.redcross.int
- MSF Catalogue, “Forceps, Magill, adult, 24 cm” (product 12500), checked 1 November 2026: unicat.msf.org
- FDA 510(k) database, K880319, MAGILL FORCEPS, checked 1 November 2026: api.fda.gov (510(k) record) and accessdata.fda.gov
- FDA product classification (openFDA), product code BWB, 21 CFR 868.5780, checked 1 November 2026: api.fda.gov