Lensometer Parts and Functions: A Component-by-Component Guide

Each lensometer part and what it measures, American Cross vs European Dot vs automated types, and the Class I status under 21 CFR 886.1425.

Written and maintained by CASRAI Editorial Board

Published · Last updated

This page describes products and general use; it is not medical advice.

On this page

A lensometer (also called a lensmeter or focimeter) is a bench instrument that reads the prescription power of a pair of glasses or a single lens. This guide maps each lensometer part to the measurement it makes possible, shows which parts belong to which instrument type, and states the instrument’s regulatory identity. Who uses it: optometry and ophthalmology staff, opticians, and trainees who verify or neutralize lenses.

What a lensometer is

A lensometer measures the power of a lens. According to the American Academy of Ophthalmology’s EyeWiki entry on lensometry, it is used to establish or verify the reference refractive prescription before an eye exam and to neutralize single-vision, bifocal, trifocal, progressive, prismatic and rigid gas permeable (RGP) contact lenses. In U.S. device regulation it is a “lens measuring instrument”: 21 CFR 886.1425 defines it as an AC-powered device intended to measure the power of lenses, prisms, and their centers (e.g., lensometer). The ISO name for the instrument class is “focimeter” (ISO 8598-1).

Clinics list the lensmeter as one item in a wider equipment set; see the optometry clinic supply checklist for the surrounding equipment, and parts of eyeglasses for the lens and frame components being measured.

Lensometer parts and what each does

The table below follows the parts described in EyeWiki’s Lensometry entry. Not every part is present on every instrument; the last column notes where EyeWiki ties a part to a specific type.

Part Function Notes
Eyepiece Adjusted for the examiner’s own refractive error before measuring so the target is seen in focus Manual instruments
Power wheel Rotated to bring the target into focus; gives sphere power Manual instruments
Target Pattern viewed through the eyepiece; in the American Cross type, thin lines relate to sphere and thick lines to cylinder American Cross type
Axis wheel / dial Used with the power wheel to find the cylinder axis Manual instruments
Axis marker and protractor grid Reads the axis European Dot type
Reticle Movable plate; the lens is shifted on it to centre the target and locate the optical centre Manual instruments
Lens stop and lens holder Hold the lens in position during measurement All types
Concentric rings Each ring represents 1 prism diopter; displacement of the target shows prism and its base direction Manual instruments
Prism compensating device A knob that changes prism power and base direction Optional feature
Contact lens stop Replaces the standard lens stop with a smaller aperture for RGP lenses Accessory
Angle lever Sets a comfortable viewing angle for the examiner Manual instruments
Power switch and LED illumination Turn on the light source Manual instruments are battery-powered LED
Marking pen Marks the optical centre on the lens Accessory
Polariscope A separate tool that locates the add on multifocal lenses Separate tool

Manual versus automated lensometers

Manual

EyeWiki describes the manual lensometer as a battery-powered LED instrument that measures sphere, cylinder, axis, add and prism. Two common designs exist, American Cross and European Dot, which differ in the target and in how axis is read (see the table).

Automated

An automated lensometer uses white light and a ray-trace system, measures all values in one operation, shows them on a digital display and can print them. EyeWiki describes it as faster and easier to use, but relatively less accurate than a manual instrument.

What is a lensometer used for?

The documented uses are verifying the reference prescription before an eye exam and neutralizing lenses of the types listed above. The optometry clinic supply checklist also lists it among clinic equipment. Practices that stock diagnostic equipment can browse diagnostic, monitoring and imaging products.

How the parts work together in a reading

On a manual instrument the examiner first focuses the eyepiece, then places the lens against the lens stop and uses the reticle to centre the target and find the optical centre, which can be marked with the marking pen. The power wheel gives sphere power; for a lens with cylinder, each meridian is neutralized separately, the cylinder is the difference between the two readings, and the axis comes from the axis wheel. For bifocals and trifocals the add is the near reading minus the distance reading. Prism is read from the concentric rings or with the compensating device. For RGP lenses the contact lens stop replaces the standard stop and the lens is placed with its convex side toward the examiner.

Regulatory status

Under 21 CFR 886.1425 a lens measuring instrument is Class I (general controls) and is exempt from premarket notification under subpart E of part 807, subject to the limitations in 886.9 (checked 2026-10-31). ISO 8598-1:2014 specifies general-purpose focimeters that measure vertex power, cylinder axis, prism power and prism base setting at a point on a lens; it excludes focimeters with additional functions or higher precision, such as those for spectacle lens manufacturing (checked 2026-10-31). For how other jurisdictions classify devices, see EU MDR classification rules. For a related ophthalmic instrument, see what is an ophthalmoscope.

Common mistakes

  • Skipping the eyepiece adjustment: EyeWiki states the eyepiece is set for the examiner’s own refractive error before measuring.
  • Reading without centring the target: the reticle exists so the lens can be shifted until the target is centred and the optical centre located.
  • Measuring an RGP lens with the standard stop or the wrong orientation: EyeWiki specifies the contact lens stop and the convex side toward the examiner.
  • Treating one meridian as the whole lens: cylinder is found by neutralizing each meridian separately.

FAQ

What is a lensometer?

A lensometer, also called a lensmeter or focimeter, is an instrument that measures the power of lenses, prisms and their centres. In the U.S. it is a Class I lens measuring instrument under 21 CFR 886.1425.

What are lensometer uses?

It is used to establish or verify a reference prescription before an eye exam and to neutralize single-vision, bifocal, trifocal, progressive, prismatic and RGP lenses (AAO EyeWiki).

What are the main parts of a lensometer?

The eyepiece, power wheel, target, axis wheel or dial, reticle, lens stop and holder, prism rings and compensator, angle lever, and illumination, plus accessories such as the contact lens stop and marking pen.

Sources

  • American Academy of Ophthalmology EyeWiki, “Lensometry”: https://eyewiki.aao.org/Lensometry (checked 2026-10-31)
  • 21 CFR 886.1425, lens measuring instrument: https://www.law.cornell.edu/cfr/text/21/886.1425 (checked 2026-10-31)
  • ISO 8598-1:2014, Optics and optical instruments, focimeters, general purpose instruments (scope as listed in the ISO catalogue, checked 2026-10-31)

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Lensometer Parts and Functions: A Component-by-Component Guide

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →