A liquid nitrogen SDS classifies refrigerated liquid nitrogen as a refrigerated liquefied gas with hazard statement H281, “Contains refrigerated gas; may cause cryogenic burns or injury”, under the signal word Warning. The suppliers’ sheets read for this page also list the substance as non-flammable, transported as UN 1977, and an asphyxiation risk, but they do not all place that last risk in the same part of the sheet.
Short answer: what the liquid nitrogen SDS says
Three supplier sheets were read in full for this guide: Dakota Gas (a US sheet written to the OSHA Hazard Communication Standard 2012 and WHMIS), Air Liquide Malaysia (SDS 92, revision of 3 April 2024, written to the Malaysian industry code of practice) and Linde (REACH Annex II format, version 1.3, revised 23 August 2021). All three agree on the core classification and label elements:
- Classification: gases under pressure, refrigerated liquefied gas, hazard statement H281.
- Signal word and pictogram class: Warning.
- Precautionary statements: P282 (wear cold insulating gloves and face shield or eye protection) and P403 (store in a well-ventilated place). All three sheets also print a response line, P336 (thaw frosted parts with lukewarm water, do not rub) with P315 (get immediate medical advice).
- Transport: UN 1977, nitrogen, refrigerated liquid, class 2.2.
- Flammability: not flammable.
Where they differ is just as useful to know, because those differences decide what a lab’s own hazard summary, door sign and risk assessment should say. They are set out below and in the data table further down the page.
Definition and scope: what an SDS covers for liquid nitrogen
A safety data sheet is the supplier’s structured statement of a product’s identity, hazards, handling, exposure controls, disposal and transport information, issued in the format that applies in the supplier’s jurisdiction. For liquid nitrogen, that jurisdiction-dependent format is why the sheets are not interchangeable: the US sheet follows the OSHA Hazard Communication Standard and adds WHMIS (Canadian) information, the Malaysian sheet follows the national industry code of practice, and the Linde sheet follows the EU REACH Annex II layout with classification under Regulation (EC) 1272/2008.
Liquid nitrogen is nitrogen cooled to a boiling point of −196 °C (Linde gives a boiling point of −196 °C, a melting point of −210.01 °C and a critical temperature of −147.0 °C). Nitrogen makes up about 78% of the atmosphere (Dakota Gas, section 12), so the gas itself is not toxic. The hazards on the sheet come from the temperature, from the large volume of gas produced when the liquid warms, and from the way that gas displaces air. For the physics of the −196 °C figure, see our guide to liquid nitrogen temperature.
This guide is about reading the SDS. It does not repeat handling procedures. For dewar handling, personal protective equipment and transfer practice, use liquid nitrogen and cryogen handling safety. For nitrogen supplied as a compressed gas in cylinders, which has a different classification and storage situation, see nitrogen gas SDS.
How the classification and hazards are expressed in practice
Liquid nitrogen hazards as the sheets state them
The hazards named across the sheets and the University of Washington IsoLab liquid nitrogen procedure fall into four groups.
- Extreme cold. H281 itself names cryogenic burns or injury. Dakota Gas notes that at −196 °C the liquid freezes organisms on contact (section 12). The IsoLab procedure lists cold at −196 °C as a primary hazard.
- Asphyxiation. Dakota Gas adds the line “May displace oxygen and cause rapid suffocation” to its label text and classes liquid nitrogen as a “simple asphyxiant”. It also states that there are no warning symptoms of oxygen deficiency. Linde describes nitrogen as odourless with an inadequate odour threshold to warn of its presence. Air Liquide recommends oxygen detectors where asphyxiating gases may be released (section 6).
- Pressure. Dakota Gas lists a pressure (sudden release) hazard under its SARA hazard categories. The IsoLab procedure states that high pressure can build up if the liquid is enclosed in an airtight container, and that containers made for liquid nitrogen have loose-fitting caps by design.
- Brittle and failing materials. Air Liquide notes that liquid spills can embrittle structural materials and that carbon steel, low-alloy carbon steel and plastic become brittle at low temperature (it refers readers to ISO 11114). Dakota Gas says some materials become extremely brittle and that containers must be of cryogenic-suitable material. The IsoLab procedure adds that glass dewars can implode.
Exposure limits
The Linde sheet states that none of the components has an assigned exposure limit. That means there is no sheet-supplied number to compare an air reading against. The sheets instead point to oxygen monitoring: Air Liquide advises oxygen detectors where asphyxiating gases may be released, and Air Liquide’s PPE section names a self-contained breathing apparatus or positive-pressure airline for oxygen-deficient atmospheres. These are the sheet’s statements; a site-specific oxygen alarm set point is a decision for the institution’s safety office, not something the SDS supplies.
Incompatibilities and storage
Dakota Gas lists a reaction hazard: liquid nitrogen “may react vigorously with lithium, titanium, neodymium, zirconium, and many other reactive metals”. Air Liquide advises keeping the product away from combustible materials. Linde, by contrast, states “No reaction with any common materials in dry or wet conditions” in section 10 while still warning in section 10.5 that cryogenic liquids can embrittle some metals. All three agree that nitrogen itself does not burn. Storage on all three sheets comes down to P403: a well-ventilated place.
Disposal and first aid wording
Disposal instructions differ in kind. Dakota Gas refers to local and national regulations. Air Liquide and Linde both say the product may be vented to atmosphere in a well-ventilated place, and Air Liquide adds that unused product should be returned to the supplier. Linde also gives a European Waste Catalogue code (16 05 05) for the container, not the liquid. Section 4 of the Air Liquide sheet carries general first-aid wording for frostbite and eye contact; that wording belongs to the sheet and the supplier, and a lab should take its response arrangements from its occupational health provider and emergency procedure.
Types and related concepts: how the supplier sheets differ
The data table below compares the three sheets row by row. Reading across it produces four points that no single sheet states.
Asphyxiation can sit in three different places
On the Dakota Gas sheet, asphyxiation is part of the classification: the product is labelled a simple asphyxiant, and the WHMIS class is Compressed Gas A. On the Air Liquide sheet the same hazard is listed under “other hazards which do not result in classification”: asphyxiant in high concentrations. On the Linde sheet it is not a classified hazard; the sheet’s warning on odour (an inadequate warning threshold) is the nearest equivalent. A lab that builds a hazard summary from the classification section alone would therefore list asphyxiation from one sheet and omit it from another, even though the physical hazard is identical.
Label statements are printed in different layouts
All three sheets print P282, P315, P336 and P403. They differ in layout: the Linde sheet combines the response statements as P336+P315, while the Dakota Gas and Air Liquide Malaysia sheets list them separately. A reader comparing sheets should compare the statements themselves, not the way each supplier groups them.
Incompatibility wording ranges from specific metals to “no reaction”
One sheet names reactive metals, one speaks only about embrittlement and combustible materials, and one says there is no reaction with common materials. A lab that stores lithium or other reactive metals near a nitrogen dewar needs a risk assessment of its own; the least restrictive sentence among the sheets is not a clearance.
Some sheets still carry cylinder wording
Section 7 of the Dakota Gas sheet still uses wording that suits gas cylinders, so a reader should check that handling text actually fits a dewar or bulk liquid supply. The IsoLab procedure takes the opposite approach for its laboratory: it links the SDS, requires staff to read it and requires an EHS course before use.
Where the SDS matters for labs, EHS officers and supply decisions
For a laboratory, the SDS is the document a hazard assessment and a training record should point to. Because the three sheets agree on H281, UN 1977 and non-flammability but differ on asphyxiant labelling, incompatibilities and disposal, the useful routine is to read the sheet from the supplier that actually fills your dewars, not a generic sheet from the internet, and to check the following on it.
A checklist for reading your supplier’s liquid nitrogen SDS
- Revision date and jurisdiction (header and section 1). The sheets read here carry dates from 2019 (Dakota Gas), 2021 (Linde) and 2024 (Air Liquide), and each is written for a different regulatory framework. Confirm the sheet matches the country you operate in.
- Classification and label elements (section 2). Confirm H281, the signal word and the P-statements, and check whether asphyxiation is classified or listed as an unclassified hazard.
- Handling and storage (section 7). Check that the text refers to cryogenic liquids and not just cylinders, and that it names cryogenic-suitable containers.
- Exposure controls and PPE (section 8). Look for the glove and eye-protection standard the supplier names. Air Liquide cites EN 511 cold insulating gloves for transfilling and EN 166 goggles with a face shield.
- Stability and incompatibilities (section 10). Look for reactive metals, combustible materials and material embrittlement.
- Disposal (section 13). Note whether the sheet says to vent in a well-ventilated place, return to the supplier or follow local regulations.
- Transport (section 14). Confirm UN 1977, class 2.2. Air Liquide also lists special provisions 345 and 346, a limited quantity of 120 ml and packing instruction P203.
- Product grade. A different grade of liquid nitrogen has its own sheet, so make sure the sheet you file matches the product delivered.
The same habit applies to other gases and cryogens a lab holds. Our guides to carbon dioxide SDS and nitrogen gas SDS use the same section-by-section approach.
Common misunderstandings
- “Nitrogen is inert, so it is not hazardous.” The classification is H281 and the sheets describe cryogenic injury and oxygen displacement. Nitrogen being 78% of air does not make an enclosed, oxygen-depleted space safe.
- “If the sheet does not list an exposure limit, no monitoring is needed.” Linde states that no limit is assigned and the sheets that address odour state that it gives no reliable warning. The sheets’ own mitigation is oxygen detection, not smell.
- “The first SDS that appears in a search is the right one.” The sheets differ by supplier, jurisdiction and date, as shown above.
- “A tightly sealed container is safer.” The IsoLab procedure warns of high pressure when liquid nitrogen is enclosed in an airtight container and specifies loose-fitting caps made for the purpose.
- “MSDS and SDS are different documents.” The older term “MSDS” is still used in searches and file names. The documents covered here are current-format safety data sheets.
This page summarises supplier documents for general information. The sheet issued with your product and your institution’s safety office rules take precedence.
Sources
- Dakota Gas: Liquid Nitrogen SDS Rev. 6 (revision date 10/02/2019), checked 2026-11-17
- Air Liquide Malaysia: SDS 92 Nitrogen, refrigerated (revision 3 April 2024), checked 2026-11-17
- Linde: Nitrogen, refrigerated, liquid (Biogon N liquid) safety data sheet, version 1.3, revised 23 August 2021, checked 2026-11-17
- University of Washington IsoLab: Liquid nitrogen standard operating procedure, checked 2026-11-17
Data: Liquid nitrogen SDS comparison: Dakota Gas, Air Liquide Malaysia and Linde
Side-by-side comparison of what three supplier safety data sheets for refrigerated liquid nitrogen state on classification, asphyxiation, label statements, incompatibilities, disposal and transport. Compiled by reading each sheet in full; every cell is the sheet's own content, summarised.
| Item | Dakota Gas (rev. 10/02/2019) | Air Liquide Malaysia SDS 92 (rev. 2024-04-03) | Linde Biogon N liquid (v1.3, 2021-08-23) |
|---|---|---|---|
| Framework | OSHA HCS 2012 and WHMIS | ICOP 2014/2019 (Malaysia) | REACH Annex II, Regulation (EC) 1272/2008 |
| Classification | Refrigerated liquefied gas, H281 | Refrigerated liquefied gas, H281 | Refrigerated liquefied gas, H281 |
| Signal word | Warning | Warning | Warning |
| Asphyxiation treatment | Simple asphyxiant; label line on rapid suffocation; WHMIS Compressed Gas A | Other hazard not resulting in classification: asphyxiant in high concentrations | Not classified; odour threshold inadequate to warn |
| P-statements printed | P282, P336, P315, P403 | P282, P315, P336, P403 | P282, P336+P315, P403 |
| Incompatibility wording | May react vigorously with lithium, titanium, neodymium, zirconium and other reactive metals | Carbon steel, low-alloy carbon steel and plastic become brittle at low temperature; keep from combustibles | Can embrittle some metals; no reaction with common materials in dry or wet conditions |
| Disposal | Per local and national regulations | Vent in well-ventilated place; return unused product to supplier | Vent in well-ventilated place; EWC 16 05 05 for the container |
Sources
- Dakota Gas: Liquid Nitrogen SDS Rev. 6 (accessed 2026-11-17)
- Air Liquide Malaysia: SDS 92 Nitrogen, refrigerated (accessed 2026-11-17)
- Linde: Nitrogen, refrigerated, liquid (Biogon N liquid) SDS (accessed 2026-11-17)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.