Written and maintained by CASRAI Editorial Board
Published
On this page
Nanofiltration (NF) is a pressure-driven membrane separation process that retains selected dissolved molecules and salts while allowing solvent and more permeable solutes through. It sits between ultrafiltration and reverse osmosis. For laboratory work, the key distinction is between a membrane’s reported rejection and the conditions under which that result was measured.
Short answer
NF can separate dissolved substances that ordinary particle filtration leaves in solution. Its usefulness depends on the separation required: reducing water hardness, removing particular organic compounds, or recovering a solvent are different tasks. A high rejection figure for one test salt does not establish performance for every component of a real mixture.
The comparison below connects three manufacturer qualification tests to the claims they support. It separates flat-sheet testing from finished-element testing and maximum salt passage from stabilized rejection. That distinction helps a researcher interpret a specification without treating it as evidence of complete purification, a universal molecular cutoff, or demonstrated long-term performance.
Definition and scope
DuPont’s NF overview describes a liquid-separation technology that can reject multivalent ions strongly while allowing more monovalent salt passage. Selectivity is central: the aim need not be to remove every dissolved species. A process may benefit from retaining an organic component while allowing some salts to pass.
The term describes separation behaviour rather than one apparatus. VITO’s EMIS technical sheet identifies flat, tubular and spiral membrane formats. Thus, a membrane coupon evaluated in a laboratory cell and a spiral-wound element can both be associated with nanofiltration, although their test arrangements differ.
Molecular-weight cut-off, or MWCO, characterizes retention using selected probe molecules. VITO describes a convention based on 90% retention and distinguishes salt probes from neutral probes such as polyethylene glycols. A cut-off therefore needs its test context. It is not a promise that every molecule above a stated molecular weight is completely retained.
Within chemical engineering, NF belongs to the broader task of designing separations around a feed and a required product. The useful question is which substances should appear in which outlet, and what evidence demonstrates that separation. The technology name alone does not answer those questions.
How nanofiltration works in practice
Applied pressure drives solvent across a selective membrane. In the crossflow arrangement described by DuPont, feed moves along the membrane surface while part crosses it. The crossing stream is the permeate; the remaining stream is the concentrate, also called retentate or reject. Crossflow helps limit material accumulation at the surface.
Flow geometry and selectivity describe different aspects of the process. Tangential flow filtration explains the arrangement of flow relative to a membrane. Calling a system crossflow does not identify which dissolved salts or molecules its membrane retains. Conversely, identifying a membrane as NF does not fully describe the test rig.
VITO attributes separation to a combination of sieving, solvent diffusion and electrostatic interactions. Membrane charge can influence ion selectivity, so a simple picture of rigid particles meeting uniformly sized holes is incomplete. Molecular weight is useful for describing a test, but charge and the selected probe also matter.
DuPont identifies pressure, temperature, recovery and feed salt concentration as performance variables. A comparison that changes these conditions together cannot attribute the entire difference to membrane identity. In interpreting two studies, preserve the operating conditions alongside the reported result rather than reducing each study to one rejection percentage.
Types and related concepts
Ultrafiltration, nanofiltration and reverse osmosis
The FilmTec technical manual distinguishes UF, which allows dissolved salts through, from NF’s partial and selective salt rejection and RO’s broader dissolved-salt rejection. These categories help frame a separation problem; they do not replace solute-specific measurements for a particular membrane.
For a lab report, name both the process class and the tested membrane. Describing a result as “NF removal” leaves readers unable to tell whether the observation concerns a particular salt, an organic compound, or a mixture. Likewise, a membrane-family comparison should keep the required product quality explicit rather than treating greater retention as automatically preferable.
Aqueous NF and organic solvent nanofiltration
Organic solvent nanofiltration, or OSN, extends the approach to solvent-based process streams using compatible membranes. Evonik’s PuraMem brochure describes solvent-stable membranes for nonpolar and slightly polar media, with applications including catalyst recovery and nonthermal solvent recovery.
Evonik identifies membrane stability and molecular selectivity as determining factors; molecular shape and polarity can also affect the separation. Its examples show why the desired product may be the retained material, the permeating solvent, or both. An aqueous salt qualification result cannot by itself establish suitability for a solvent-based chemical process.
Interpreting nanofiltration test results
The data table below compiles three reference tests from DuPont’s NF270 flat-sheet, NF270-4040 and NF90-4040 documents. It preserves each document’s result definition. The rows are a comparison of evidence, not a product ranking: one row reports maximum passage from flat-sheet testing, while the others report stabilized rejection from element testing.
Passage and rejection describe complementary fractions
The NF270 flat-sheet data sheet specifies maximum magnesium sulfate passage of 0.8%. Its qualification uses a 2,000 ppm MgSO₄ feed at 8.96 bar and 25°C, with a retentate flow of 7.9 L/min and a 20-minute test. The specification applies to mean results from the tested samples.
Illustrative calculation: expressing that passage limit as its complementary rejection gives 100 − 0.8 = 99.2%. This arithmetic changes the reporting convention; it does not change the test conditions or turn a sample qualification into an observed result from a different apparatus.
The same sheet describes monovalent rejection of about 40–60%. Consequently, the magnesium sulfate number is not an interchangeable sodium chloride result. When quoting either figure, retain the solute identity. Calling both simply “salt removal” hides the distinction that makes NF useful for selective separations.
Element results have a different qualification basis
The NF270-4040 element sheet reports stabilized magnesium sulfate rejection greater than 97.0%. The NF90-4040 sheet reports greater than 98.7%. Both state a 2,000 ppm magnesium sulfate feed, 25°C, 4.8 bar applied pressure and 15% recovery.
Those two element qualifications share stated conditions. The flat-sheet qualification uses a different pressure and hydraulic description. It would therefore be misleading to turn the three thresholds into a league table of membrane quality. They answer different qualification questions, and none is a direct measurement of the reader’s feed.
The direction of each threshold also matters. A maximum passage specification sets an upper bound on the reported passage; “greater than” rejection sets a lower bound on the reported rejection. Neither notation supplies an exact observed value. When transcribing a specification into a report or spreadsheet, keep the qualifier with the number. Replacing “greater than 97.0%” with “97.0% measured rejection” would turn a qualification threshold into an invented measurement. Similarly, the flat-sheet document’s reference to mean sample results should remain attached to that qualification rather than becoming a guarantee for every coupon.
Recovery describes water yield
The FilmTec manual defines recovery as permeate flow divided by feed flow. Illustrative composite: a hypothetical system receiving 100 L/h and producing 75 L/h permeate has 75% recovery and, assuming no other outlet or accumulation, 25 L/h concentrate. These are invented inputs for arithmetic, not experimental observations or recommended operating settings.
That flow balance says nothing about a solute’s rejection. To describe the separation, the example would also need concentration measurements and their sampling basis. A statement of recovery therefore belongs beside, rather than in place of, the evidence about permeate composition.
Where nanofiltration matters for labs and process decisions
The US EPA’s treatment overview identifies NF uses including hardness reduction and removal of colour and odour compounds, synthetic organic chemicals, and some disinfection-byproduct precursors. It also emphasizes pretreatment to control fouling or plugging and management of the contaminant-bearing concentrate.
This separates two questions for a water-treatment study: whether the permeate meets the intended objective, and what happens to the retained material. Removal from the product stream does not make the concentrate disappear. A study boundary that stops at permeate quality leaves part of the process unexplained.
For laboratory supply discussions, distinguish a separation technology from the complete water system and its intended output. The broader laboratory water purification system guide provides that system context. An NF qualification table is evidence about a membrane test, rather than a complete specification for every downstream laboratory use.
An evidence checklist for reading a study or specification
The following reading aid combines the product-sheet qualifications with DuPont’s testing guidance and Evonik’s development stages. It concerns what a claim establishes, rather than instructions for running a pressurized experiment.
- Membrane identity and format: distinguish the flat-sheet sample from the finished element, and retain the source document’s revision.
- Feed and target: identify the named test substance, its concentration, and whether the application uses water or an organic solvent.
- Hydraulic basis: preserve test pressure, temperature and the stated recovery or retentate-flow condition. These are part of the result.
- Reported endpoint: distinguish passage, rejection and recovery; preserve whether a value is a maximum or a greater-than threshold.
- Extent of evidence: distinguish membrane screening from application testing and longer-term pilot evidence before describing scale-up as demonstrated.
DuPont explicitly says that a small flat-sheet screening test cannot provide engineering scale-up data or establish long-term fouling behaviour. Evonik likewise separates initial flat-sheet screening from small-module proof-of-process trials. A promising short test supports further development; it does not alone establish sustained process performance.
Common misunderstandings
“A high rejection number proves sterile water”
It does not. The NF270 element sheet warns that the product alone does not guarantee cyst and pathogen removal; effective reduction depends on complete system design, operation and maintenance. A magnesium sulfate qualification measures a different endpoint and cannot serve as a microbiological validation.
“The largest pressure in the document is the test pressure”
The NF90-4040 sheet distinguishes 4.8 bar qualification pressure from a 41 bar maximum operating pressure. These values have different purposes. Substituting the maximum into a description of the rejection test changes the evidence rather than clarifying it. The same document calls for removal of residual free chlorine before membrane exposure, showing why compatibility conditions also belong to a product-specific reading.
“A conductivity result identifies every retained solute”
The FilmTec manual treats conductivity-to-TDS conversion as stream-specific. Keep the conductivity units, temperature basis and conversion assumptions explicit. A bulk conductivity comparison is not the same measurement as a named compound’s concentration. In a selective separation, those endpoints answer different questions and should be reported separately.
Sources
- DuPont: Nanofiltration (NF). Checked 2026-11-14.
- VITO EMIS: Nanofiltration technical sheet. Checked 2026-11-14.
- US EPA: Overview of Drinking Water Treatment Technologies, reverse osmosis/nanofiltration. Checked 2026-11-14.
- DuPont: FilmTec Reverse Osmosis/Nanofiltration Technical Manual, 45-D01504-en, Rev. 20, August 2026, sections 1.2–1.3, 3.13 and 5.6. Checked 2026-11-14.
- DuPont: NF270 NF Flatsheet, 45-D01987-en, Rev. 3, January 2026. Checked 2026-11-14.
- DuPont: NF270 Element for Commercial Systems, 45-D01529-en, Rev. 8, January 2025. Checked 2026-11-14.
- DuPont: NF90 Element for Commercial Systems, 45-D01520-en, Rev. 8, April 2026. Checked 2026-11-14.
- Evonik: PuraMem organic solvent nanofiltration brochure. Checked 2026-11-14.
Data: Nanofiltration qualification tests: flat sheet versus elements
Original compilation of three DuPont qualification documents. Each uses a 2,000 ppm magnesium sulfate feed. Flat-sheet maximum passage and element stabilized rejection are different metrics; values are thresholds, not comparable field performance. The flat-sheet test specifies 7.9 L/min retentate flow and a 20-minute test rather than recovery. The element documents specify 15% recovery. Test pressures are not maximum operating pressures.
| Membrane and document revision | Applied test pressure (bar) | Test temperature (°C) | Test recovery (%) | Magnesium sulfate threshold (%) | Metric and qualifier |
|---|---|---|---|---|---|
| FilmTec NF270 NF Flatsheet; 45-D01987 Rev.3 | 8.96 | 25 | Not reported | 0.8 | Maximum passage; mean sample qualification |
| FilmTec NF270-4040; 45-D01529 Rev.8 | 4.8 | 25 | 15 | 97 | Stabilized rejection greater than threshold |
| FilmTec NF90-4040; 45-D01520 Rev.8 | 4.8 | 25 | 15 | 98.7 | Stabilized rejection greater than threshold |
Sources
- DuPont NF270 NF Flatsheet, 45-D01987-en Rev.3 January 2026 (accessed 2026-11-14)
- DuPont NF270 Element, 45-D01529-en Rev.8 January 2025 (accessed 2026-11-14)
- DuPont NF90 Element, 45-D01520-en Rev.8 April 2026 (accessed 2026-11-14)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.







