NanoLuc (often designated in genetic constructs as Nluc) is an engineered 19.1 kDa monomeric luciferase derived from the deep-sea shrimp Oplophorus gracilirostris that catalyzes the oxidative decarboxylation of the novel imidazopyrazinone substrate furimazine to produce high-intensity, glow-type bioluminescence with an emission peak at 460 nm. Engineered through directed evolution by Promega Corporation, NanoLuc produces approximately 150-fold higher specific luminescence activity per molecule than traditional firefly (Photinus pyralis) or Renilla reniformis luciferases without requiring ATP, magnesium, or coenzyme A. Its compact 171-amino-acid structure, exceptional thermal stability up to 55 to 60 °C, and compatibility with split-protein complementation systems such as HiBiT and NanoBiT have established it as a foundational reporter for gene regulation, live-cell protein-protein interactions, and targeted protein degradation assays across molecular biology and high-throughput drug screening.
Definition and Scope of NanoLuc Luciferase
In modern biological research, bioluminescent reporters provide quantitative, non-destructive optical readouts for gene expression, receptor activation, and cellular kinetics. For decades, the standard luciferase reporter assay relied primarily on two naturally occurring enzymes: firefly luciferase (Fluc, 61 kDa) from Photinus pyralis and sea pansy luciferase (Rluc, 36 kDa) from Renilla reniformis. While these classical enzymes enabled dual-reporter assays and high-throughput screening, their application remained constrained by large genetic footprints, thermal sensitivity, moderate quantum yields, and susceptibility to off-target compound interference in chemical libraries.
NanoLuc luciferase (and its genetic designation, nluc luciferase) represents a synthetic biology solution engineered to overcome these biophysical constraints. By isolating and restructuring the catalytic core of a marine bioluminescent complex, protein engineers produced a 19.1 kDa enzyme composed of a single 171-amino-acid polypeptide chain. Unlike multimeric reporters or enzymes requiring post-translational lipid modifications or assembly chaperones, NanoLuc folds spontaneously into an active conformation in both prokaryotic and eukaryotic hosts. Its bioluminescent reaction relies on furimazine (2-furanylmethyl-deoxycoelenterazine), an engineered substrate tailored specifically to fit the enzyme’s optimized catalytic pocket.
The operational scope of NanoLuc spans four primary assay domains:
- Transcriptional and genetic reporting: Serving as an ultra-sensitive transcriptional reporter where promoter activity or mRNA regulatory elements yield detectable luminescence even at low expression levels.
- Protein tagging and abundance quantification: Fusing either full-length NanoLuc or high-affinity split fragments directly to target proteins to monitor endogenous expression without requiring antibody-based detection.
- Dynamic protein-protein interactions: Partitioning the enzyme into low-affinity complementary subunits (the NanoBiT system) that associate reversibly only when guided by interacting protein partners.
- Resonance energy transfer (BRET): Functioning as a high-intensity bioluminescent donor in proximity assays (NanoBRET) to measure protein-protein interactions, receptor conformational changes, and small-molecule target engagement in intact living cells.
Structural Basis and Molecular Engineering Lineage
The structural origin of NanoLuc traces to Oplophorus gracilirostris, a deep-sea bathypelagic shrimp that expels a luminescent blue cloud into the water column when threatened. Biochemical characterization by Shimomura and colleagues in the 1970s revealed that this natural bioluminescent secretion is produced by a 106 kDa heterotetrameric complex consisting of two 35 kDa subunits and two 19 kDa subunits. While the 35 kDa subunits functioned primarily as protective carriers, the catalytic luciferase activity resided entirely within the 19 kDa subunit (Opluc-19). However, native Opluc-19 suffered from poor aqueous solubility, low intracellular stability, and rapid thermal inactivation when expressed as an isolated polypeptide in heterologous expression systems.
In the seminal 2012 study led by Mary P. Hall and Keith V. Wood at Promega Corporation, researchers initiated a comprehensive directed evolution program starting from recombinant Opluc-19. Through successive rounds of random mutagenesis, error-prone PCR, and functional luminescence screening, the team introduced 16 specific amino acid substitutions distributed across the core polypeptide scaffold. These substitutions restructured surface-exposed hydrophobic patches, enhanced internal core packing, and stabilized flexible surface loops, culminating in the creation of NanoLuc.
High-resolution crystallographic investigations show that NanoLuc adopts a compact, highly ordered β-barrel fold enclosing an internal hydrophobic cavity that accommodates the imidazopyrazinone substrate. This structural arrangement confers remarkable physical and chemical resilience:
- Thermal resistance: NanoLuc exhibits an apparent melting temperature (Tm) exceeding 55 to 60 °C, maintaining complete enzymatic activity across extended incubations at physiological temperatures (37 °C) where firefly and Renilla luciferases rapidly lose activity.
- Chemical denaturant tolerance: The enzyme retains measurable catalytic turnover in the presence of 8 M urea or non-ionic and zwitterionic detergents, allowing researchers to perform lytic assays directly in robust cell lysis buffers.
- pH stability: NanoLuc functions efficiently across a broad pH range from 6.0 to 8.5, retaining optimal catalytic activity around neutral physiological pH (7.4 to 7.8).
- Thermal shift applications: Because of its well-defined denaturation curve and compatibility with cell lysates, NanoLuc fusions serve as robust reporters in advanced biophysical assays such as the cellular thermal shift assay (CETSA) to track drug-induced target protein stabilization.
Furimazine Reaction Chemistry and Catalytic Mechanism
A central breakthrough in developing NanoLuc was the simultaneous co-engineering of its synthetic substrate, furimazine. Traditional marine luciferases, including Renilla and Gaussia, utilize native coelenterazine as their luminescent substrate. While coelenterazine emits blue light upon oxidation, it presents severe limitations in cellular bioassays: it undergoes rapid spontaneous auto-oxidation in aqueous buffers (generating background chemiluminescence) and binds non-specifically to serum albumin and other hydrophobic proteins in culture media, producing uncoupled background light that degrades assay sensitivity.
To eliminate this background, medicinal chemists synthesized a series of imidazopyrazinone analogs modifying the C-2, C-6, and C-8 positions of the coelenterazine core. Replacing the benzyl group at the C-2 position with a 2-furanylmethyl moiety yielded furimazine (chemical designation: 2-furanylmethyl-deoxycoelenterazine). Furimazine exhibits dramatically suppressed spontaneous auto-oxidation, virtually eliminating background autoluminescence in cell culture medium and buffer containing fetal bovine serum (FBS). Furthermore, the catalytic cavity of NanoLuc was evolved specifically to accommodate furimazine, resulting in a substrate-enzyme pairing with high catalytic turnover (kcat/Km) and exceptional optical output.
The chemical reaction catalyzed by NanoLuc proceeds via the oxidative decarboxylation of furimazine in the presence of dissolved molecular oxygen:
Furimazine + O2 → Furimamide + CO2 + Light (λmax = 460 nm)
In this monooxygenase mechanism, the enzyme activates molecular oxygen to form a dioxetanone intermediate across the imidazopyrazinone ring. Spontaneous collapse of this cyclic intermediate expels carbon dioxide and leaves the reaction product, furimamide, in an electronically excited singlet state. As the excited furimamide relaxes to its electronic ground state, it releases a photon of blue light with a narrow spectral bandwidth centered at 460 nm.
Crucially, this enzymatic reaction is entirely ATP-independent. Unlike firefly luciferase, which strictly requires ATP, magnesium ions (Mg2+), and molecular oxygen to form a luciferyl-adenylate intermediate, NanoLuc requires only furimazine and dissolved oxygen. This cofactor independence prevents luminescence variations caused by fluctuations in cellular metabolic state or intracellular ATP pools, an important distinction when evaluating energetic perturbagens compared to dedicated ATP bioluminescence assays.
NanoLuc vs Conventional Luciferase Reporters
The practical superiority of NanoLuc over historical luciferase reporters arises from the convergence of four distinct parameters: size, specific activity, reaction kinetics, and cofactor independence. The data table below compares quantitative biophysical and assay parameters across five major bioluminescent reporter systems.
From a size perspective, NanoLuc (19.1 kDa, 171 amino acids) is less than one-third the size of firefly luciferase (61 kDa, 550 amino acids) and roughly half the size of Renilla luciferase (36 kDa, 311 amino acids). In genetic engineering, smaller transgene length translates directly into higher viral packaging titers in lentiviral and adeno-associated viral (AAV) vectors, where packaging limits are stringent (typically ~4.7 kb for AAV). Furthermore, when expressing reporter fusion proteins, smaller tags minimize steric hindrance, preserve native protein folding, and prevent aberrant subcellular mislocalization.
In terms of light emission, purified NanoLuc delivers an approximate 150-fold increase in specific activity compared to equivalent molar quantities of firefly or Renilla luciferases. In mammalian cell cultures, this translates to signal detection limits extending into the sub-femtomolar range. Researchers can detect reporter expression driven by weak, physiologically responsive native promoters that remain undetectable when paired with firefly luciferase.
Reaction kinetics also distinguish commercial NanoLuc formulations. While wild-type marine luciferases such as Gaussia luciferase produce an intense but fleeting “flash” signal that decays within seconds, commercial Nano-Glo formulations utilize optimized buffer detergents and enzyme inhibitors that convert the reaction into a stable “glow” output. Under standard assay conditions, the luminescent signal exhibits a half-life of approximately 120 minutes (2 hours), providing ample time for batch processing and automated microplate handling without requiring automated reagent injectors.
Assay Architectures: Genetic Reporters, NanoBiT, HiBiT, and NanoBRET
The modularity of NanoLuc has enabled the creation of several distinct assay platforms that address challenges across molecular pharmacology, cell biology, and functional genomics.
1. Genetic Reporter Vector Configurations
For standard gene regulation and promoter characterization studies, NanoLuc is available in three distinct configurations depending on experimental timing and sample handling requirements. When planning vector delivery, researchers should consult established transfection optimization protocols to balance plasmid copy number against cell viability:
- Unfused NanoLuc (Nluc): The wild-type engineered enzyme expressed as an intracellular protein. Because of its extreme thermal and proteolytic stability, unfused NanoLuc accumulates in the cytoplasm over time, providing maximal light output and superior detection sensitivity for low-abundance transcripts.
- Destabilized NanoLuc-PEST (NlucP): The NanoLuc coding sequence fused at its C-terminus to a PEST degradation domain derived from mouse ornithine decarboxylase. The PEST motif targets the reporter for rapid proteasomal degradation, shortening the intracellular protein half-life from over 2 hours down to 15 to 30 minutes. This destabilization allows researchers to track real-time transcriptional upregulation and downregulation with minimal lag.
- Secreted NanoLuc (secNluc): Engineered with an N-terminal interleukin-6 (IL-6) secretion signal sequence, directing the enzyme into the endoplasmic reticulum and secretory pathway. The secreted enzyme accumulates in the cell culture supernatant, enabling repeated, non-destructive longitudinal sampling of the same culture wells over hours or days without lysing the cells.
2. NanoBiT: Reversible Split-Luciferase Complementation
To study protein-protein interactions (PPI) in living cells, NanoLuc was split into a two-subunit complementation system called NanoBiT (NanoLuc Binary Technology). Structural dissection yielded two complementary fragments:
- LgBiT (Large BiT): An 18 kDa polypeptide consisting of 156 amino acids that represents the primary structural scaffold of the enzyme.
- SmBiT (Small BiT): An 11-amino-acid peptide tag (sequence: VTGYRLFEEIL, 1.3 kDa).
Critically, the interaction affinity between LgBiT and SmBiT was deliberately engineered to be weak, possessing a dissociation constant (Kd) of approximately 190 μM. Because of this low intrinsic affinity, LgBiT and SmBiT do not self-assemble spontaneously at physiological cellular concentrations. However, when fused to two interacting protein partners (such as a GPCR and a β-arrestin), the binding of the partner proteins brings LgBiT and SmBiT into close spatial proximity, driving rapid structural complementation and restoring active furimazine oxidation. Because the complementation is reversible, NanoBiT allows real-time measurement of both complex assembly and dissociation in response to pharmacological agonists and antagonists. This dynamic reversibility provides a major operational advantage over irreversible split-fluorescent protein systems such as bimolecular fluorescence complementation.
3. HiBiT: High-Affinity Peptide Tagging for Endogenous Proteins
While SmBiT was engineered for low affinity, researchers also developed an alternative 11-amino-acid peptide variant designated HiBiT (sequence: VSGWRLFKKIS, 1.3 kDa). HiBiT binds to LgBiT with exceptionally high affinity, displaying a sub-nanomolar dissociation constant (Kd = 700 pM).
Because the HiBiT peptide comprises only 11 amino acids (encoded by a 33-base-pair nucleotide sequence), it can be knocked into endogenous genomic loci via CRISPR/Cas9 using single-stranded oligodeoxynucleotide (ssODN) donor templates with high editing efficiency. When cells expressing an endogenous HiBiT-tagged protein are lysed in the presence of purified recombinant LgBiT and furimazine, the two fragments assemble spontaneously within minutes, producing a luminescent signal directly proportional to endogenous protein concentration. This system enables rapid, quantitative, antibody-free protein measurements, eliminates Western blot variability, and allows researchers to determine kinetic degradation profiles for targeted protein degradation agents such as PROTACs and molecular glues.
4. NanoBRET: Proximity-Based Resonance Energy Transfer
Bioluminescence Resonance Energy Transfer (BRET) monitors molecular proximity (less than 10 nm) via non-radiative dipole-dipole energy transfer between a luminescent donor and a fluorescent acceptor. Traditional BRET systems (BRET1 and BRET2) suffered from low donor emission intensity and significant spectral overlap between the donor and acceptor, resulting in high background bleedthrough.
The NanoBRET platform pairs NanoLuc as the energy donor with a red-shifted fluorescent acceptor, typically Promega’s HaloTag protein covalently conjugated to a long-wavelength fluorophore (such as NanoBRET 618, emitting at 618 nm). Because NanoLuc emits sharply at 460 nm and the HaloTag 618 acceptor emits at 618 nm, the system achieves a spectral separation greater than 150 nm. This massive spectral window completely resolves donor bleedthrough, delivering signal-to-background ratios up to 10-fold higher than classic BRET assays. NanoBRET is now widely utilized in pharmaceutical discovery to quantify competitive compound binding and real-time intracellular target engagement for kinases, chromatin readers, and membrane receptors.
Protocol Optimization, Detection Hardware, and Plate Setup
Achieving reproducible, quantitative results with NanoLuc assays requires strict adherence to biochemical protocols and microplate optical parameters. Standard assays utilize an “add-mix-read” workflow, where a single reagent cocktail simultaneously lyses the host cells and supplies the substrate.
When preparing the Nano-Glo assay reagent, the Nano-Glo Luciferase Assay Substrate (furimazine dissolved in an organic carrier) is diluted into the Nano-Glo Luciferase Assay Buffer at a 1:50 volume ratio. Both components must be thawed and equilibrated to room temperature (20 to 25 °C) prior to reconstitution, as temperature gradients across microplates introduce kinetic artifacts. Reconstituted reagent retains stability at room temperature for several hours, but prolonged storage should be avoided due to slow oxidative degradation.
Detection hardware settings require careful configuration:
- Microplate selection: Researchers must use solid white or black-walled microplates. Clear-bottom or unpigmented plates allow substantial optical crosstalk between adjacent wells. Due to the extreme 150-fold brightness of NanoLuc, intense light from a high-signal well can bleed into adjacent negative control wells, falsely elevating background. For luminescence assays, opaque white plates maximize light reflection to the detector, while black-walled plates reduce crosstalk at the expense of absolute photon counts.
- Detector integration time: Typical integration times range from 0.1 to 1.0 second per well. Given NanoLuc’s high photon emission rate, integration times exceeding 1.0 second are rarely necessary and may cause detector saturation (overflowing photomultiplier tube counts) in wells with strong expression.
- Optical filtering: In standard luciferase reporter assays, measurements are taken with an open filter (no wavelength restriction) to capture all emitted photons. In NanoBRET or dual-luciferase assays (pairing NanoLuc with firefly luciferase), sequential measurement requires precise bandpass filters: a 460 nm filter (e.g., 460/40 nm) to capture NanoLuc emission, followed by a 618 nm longpass or bandpass filter to measure energy transfer.
- Live-cell continuous monitoring: While standard furimazine is ideal for lytic endpoint assays, its rapid metabolic turnover and moderate aqueous solubility make it less suitable for continuous multi-hour monitoring in living cells. For extended live-cell kinetic studies (24 to 48 hours), laboratories utilize modified pro-substrates such as Vivazine or EnduRen, which are cell-permeable esterified analogs that release active substrate continuously via intracellular esterases, maintaining stable luminescence over prolonged incubation periods.
Common Misunderstandings and Experimental Pitfalls
Despite the operational advantages of NanoLuc, researchers frequently encounter experimental pitfalls stemming from misinterpretations of its reaction chemistry and physical properties:
- Assuming NanoLuc emission matches firefly luciferase: A common misconception among new users is that NanoLuc emits yellow-green light similar to firefly luciferase (560 nm). NanoLuc emits blue light peaking at 460 nm. In optical filters designed for firefly or green fluorescent proteins (510 to 560 nm), NanoLuc emission will be heavily blocked or distorted, leading to apparent loss of signal.
- Substituting native coelenterazine for furimazine: Because coelenterazine is substantially cheaper than proprietary furimazine, laboratories occasionally attempt to run NanoLuc assays using coelenterazine. While NanoLuc can oxidize coelenterazine, the specific activity is roughly 30-fold lower, and uncoupling reactions generate severe background autoluminescence in serum-containing media, nullifying the sensitivity advantages of the system.
- Confusing HiBiT with SmBiT reversibility: Both HiBiT and SmBiT are 11-amino-acid peptides derived from NanoLuc, leading researchers to confuse their applications. HiBiT binds LgBiT with sub-nanomolar affinity (Kd = 700 pM), forming an essentially irreversible complex under physiological assay conditions; it cannot be used to measure protein dissociation. Conversely, SmBiT binds LgBiT with micromolar affinity (Kd = 190 μM), providing the rapid reversibility required for real-time protein-protein interaction studies.
- Neglecting optical well-to-well crosstalk in high-density plates: In 384-well or 1536-well plate formats, NanoLuc’s extraordinary photon flux frequently causes optical crosstalk into adjacent wells. If an uninduced negative control sits directly next to a maximally induced positive control in a standard white plate, light tunneling through the plastic can elevate the apparent basal signal of the control by several hundred relative light units (RLUs). Using black-walled plates or leaving buffer-filled spacer wells between extreme conditions prevents false-positive reads.
- Attempting to measure ATP depletion with NanoLuc: Because firefly luciferase is commonly used to quantify intracellular ATP in cell viability assays, investigators sometimes assume NanoLuc can be substituted into the same metabolic viability workflows. NanoLuc is entirely ATP-independent and cannot measure cellular ATP concentrations.
Frequently asked questions
What is the difference between NanoLuc and firefly luciferase?
NanoLuc is an engineered 19.1 kDa monomeric luciferase derived from deep-sea shrimp that uses furimazine as a substrate, emits blue light at 460 nm, and does not require ATP. In contrast, firefly luciferase is a 61 kDa enzyme from Photinus pyralis that utilizes D-luciferin, requires ATP and magnesium as cofactors, and emits yellow-green light at 560 nm. NanoLuc is approximately 150-fold brighter per molecule than firefly luciferase.
What substrate does NanoLuc luciferase use?
NanoLuc uses furimazine, a synthetic imidazopyrazinone analog (2-furanylmethyl-deoxycoelenterazine). Furimazine was developed through rational chemical synthesis to match the engineered active site of NanoLuc, minimize spontaneous auto-oxidation in cell culture media, and eliminate non-specific background luminescence from serum proteins.
How does the HiBiT tagging system differ from full-length NanoLuc?
Full-length NanoLuc is a complete 171-amino-acid (19.1 kDa) enzyme that produces luminescence directly upon addition of furimazine. HiBiT is an 11-amino-acid peptide tag (VSGWRLFKKIS, 1.3 kDa) representing a small fragment of NanoLuc. HiBiT is enzymatically inactive on its own but binds spontaneously and with high affinity (Kd = 700 pM) to a complementary 18 kDa protein fragment called LgBiT. When LgBiT and furimazine are added to a sample containing HiBiT-tagged protein, the active enzyme reconstitutes to produce light.
Can NanoLuc be used for in vivo imaging in animal models?
Yes, NanoLuc is widely used for in vivo bioluminescence imaging in small animal models, but its native blue emission at 460 nm is significantly absorbed and scattered by hemoglobin and melanin in mammalian tissues. To optimize in vivo performance, researchers use red-shifted BRET fusion reporters such as Antares (emitting at 580 nm) or paired fluorinated substrates such as fluorofurimazine (FFz), which offer superior tissue penetration and aqueous bioavailability in living mice.
Why is NanoLuc luciferase ATP-independent?
NanoLuc functions as a monooxygenase that directly catalyzes the oxidative decarboxylation of furimazine in the presence of molecular oxygen, requiring no energetic input from nucleotide triphosphates. Firefly luciferase requires ATP to adenylate D-luciferin prior to oxygenation, whereas marine luciferases like NanoLuc have evolved a catalytic mechanism that activates molecular oxygen directly within the imidazopyrazinone-binding pocket.
Sources
- Hall, M. P., Unch, J., Binkowski, B. F., Valley, M. P., Butler, B. L., Wood, M. G., Otto, P., Zimmerman, K., Vidugiris, G., Machleidt, T., Robers, M. B., Benink, H. A., Eggers, C. T., Slater, L. P., Meisenheimer, P. L., Klaubert, D. H., Fan, F., Encell, D. A., and Wood, K. V. (2012). Engineered Luciferase Reporter from a Deep Sea Shrimp Utilizing a Novel Imidazopyrazinone Substrate. ACS Chemical Biology, 7(11), 1848–1857. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3526014/ (Checked 2026-11-14).
- Promega Corporation. (2021). Nano-Glo Luciferase Assay System Technical Manual (Literature # TM369). https://www.promega.com/protocols/ (Checked 2026-11-14).
- Schwinn, M. K., Machleidt, T., Zimmerman, K., Eggers, C. T., Dixon, A. S., Hurst, R., Hall, M. P., Encell, L. P., Binkowski, B. F., and Wood, K. V. (2018). CRISPR-Mediated Tagging of Endogenous Proteins with a Luminescent Peptide. ACS Chemical Biology, 13(2), 467–474. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5817887/ (Checked 2026-11-14).
- Dixon, A. S., Schwinn, M. K., Hall, M. P., Zimmerman, K., Otto, P., Lubben, T. H., Butler, B. L., Binkowski, B. F., Anderson, T., Hurh, R. A., Bunge, D., and Wood, K. V. (2016). NanoLuc Complementation Reporter Optimized for Mapping Protein–Protein Interactions in Cells. ACS Chemical Biology, 11(2), 400–408. https://doi.org/10.1021/acschembio.5b00753 (Checked 2026-11-14).
- Machleidt, T., Woodroofe, C. C., Schwinn, M. K., Méndez, J., Robers, M. B., Zimmerman, K., Otto, P., Daniels, D. L., Kirkland, T. A., and Wood, K. V. (2015). NanoBRET—A Novel BRET Platform for the Analysis of Protein–Protein Interactions. ACS Chemical Biology, 10(8), 1797–1804. https://doi.org/10.1021/cb500823r (Checked 2026-11-14).
- Su, Y., Walker, J. R., Park, Y., Smith, T. P., Liu, L. X., Morrow, M. P., Zhdanova, A. V., Zhang, Y., Lin, M. Z., and Prescher, J. A. (2020). Novel fluorinated furimazine derivatives for bioluminescence imaging in mice. Nature Methods, 17(8), 852–860. https://doi.org/10.1038/s41592-020-0889-6 (Checked 2026-11-14).
- Iwano, S., Sugiyama, M., Hama, H., Watakabe, A., Hasegawa, N., Kuchimaru, T., Tanaka, K. Z., Takahashi, M., Ishida, Y., Hata, J., Shimozono, S., Namiki, S., Fukano, T., Kiyama, M., Okano, H., Kizaka-Kondoh, S., McHugh, T. J., Yamamori, T., and Miyawaki, A. (2018). Single-cell bioluminescence imaging of deep tissue in freely moving animals. Science, 359(6378), 935–939. https://doi.org/10.1126/science.aaq1067 (Checked 2026-11-14).
Data: Quantitative Biophysical and Assay Characteristics of Bioluminescent Reporter Systems
Comparison of biophysical properties, substrate requirements, emission spectra, and performance benchmarks for engineered and native bioluminescent reporters compiled from primary peer-reviewed literature and manufacturer assay manuals.
| Reporter Enzyme | Native Organism | Molecular Mass (kDa) | Amino Acid Count (aa) | Substrate | Cofactors Required | Peak Emission (nm) | Luminescence Half-Life (min) | Relative Specific Activity (fold) | Linear Dynamic Range (logs) |
|---|---|---|---|---|---|---|---|---|---|
| NanoLuc (Nluc) | Oplophorus gracilirostris (deep-sea shrimp) | 19.1 | 171 | Furimazine | None (O2 only) | 460 | 120 | 150 | 6 |
| Firefly Luciferase (Fluc) | Photinus pyralis (common eastern firefly) | 61 | 550 | D-Luciferin | ATP, Mg2+, O2 | 560 | 15 | 1 | 5 |
| Renilla Luciferase (Rluc) | Renilla reniformis (sea pansy) | 36 | 311 | Native Coelenterazine | None (O2 only) | 480 | 2 | 1 | 4 |
| Gaussia Luciferase (Gluc) | Gaussia princeps (marine copepod) | 19.9 | 185 | Native Coelenterazine | None (O2 only) | 480 | 5 | 100 | 5 |
| Akaluc | Engineered Photinus pyralis derivative | 61 | 550 | AkaLumine-HCl | ATP, Mg2+, O2 | 650 | 40 | 7 | 5 |
Sources
- Hall et al. (2012) ACS Chem Biol - Engineered Luciferase Reporter (accessed 2026-11-14)
- Promega Nano-Glo Luciferase Assay System TM369 (accessed 2026-11-14)
- Iwano et al. (2018) Science - Akaluc Bioluminescence (accessed 2026-11-14)