Written and maintained by CASRAI Editorial Board
Published
On this page
Short answer
The National Inventory of Dams (NID) is the congressionally authorized database documenting more than 90,000 dams across the United States. Maintained by the U.S. Army Corps of Engineers (USACE) under 33 U.S.C. § 467d, the NID tracks barrier specifications, inspection histories, downstream hazard ratings, and low-head dams to support public safety, flood mitigation, and hydraulic engineering research.
Definition and scope
The National Inventory of Dams is established under the National Dam Safety Program Act, codified at 33 U.S. Code § 467d. The statute mandates that the Secretary of the Army, through the U.S. Army Corps of Engineers (USACE), maintain and update an inventory of dams and low-head barriers in cooperation with federal, state, and tribal agencies.
Under 33 U.S.C. § 467(3), a structure qualifies for inclusion if it impounds water, wastewater, or liquid-borne materials and meets either physical threshold:
- Height and storage: Equal to or exceeding 25 feet in height with storage exceeding 15 acre-feet; or
- Volume threshold: Equal to or exceeding 50 acre-feet in storage with height exceeding 6 feet.
Barriers 6 feet or less in height or impounding 15 acre-feet or less are excluded unless determined to pose a significant hazard to human life or property. Levees are excluded by statute. The Low-Head Dam Inventory (LHDI) is integrated under 33 U.S.C. § 467d(g) to document run-of-the-river structures. All data layers adhere to FAIR data principles and support federal National Environmental Policy Act (NEPA) environmental reviews.
How it works or how it is used in practice
The NID operates as a federated data system. Approximately 97% of cataloged dams are non-federal structures regulated by state dam safety offices, while federal agencies (such as USACE and the Bureau of Reclamation) manage roughly 3%. State regulators conduct field inspections under local statutes and submit updated records to USACE.
The platform maintains over 70 standardized attributes per structure. Key engineering workflows include:
- Geospatial discovery: USACE provides GIS feature layers and REST services that link dam coordinates to streamflow monitoring networks in the USGS National Water Information System.
- Emergency planning: The NID tracks Emergency Action Plan (EAP) coverage and inundation mapping for high-hazard and significant-hazard impoundments.
- Hydrologic modeling: Civil engineers extract storage volumes, crest elevations, and discharge capacities to configure dam-break simulations in HEC-RAS.
Types or related concepts
The NID categorizes structures across downstream hazard potential and physical condition assessments. Hazard classifications follow Interagency Committee on Dam Safety standards in FEMA Publication 93 (FEMA 333), assessing the downstream consequences of failure rather than structural integrity.
| Category | Statutory & Regulatory Basis | Consequence / Technical Criteria | NID Significance |
|---|---|---|---|
| High Hazard Potential | FEMA 93 / 33 U.S.C. § 467(4) | Failure will probably cause downstream loss of human life. | Prioritized surveillance and mandatory EAP tracking; over 15,000 dams qualify. |
| Significant Hazard Potential | FEMA 93 / FEMA 333 | No probable loss of life, but causes economic loss, environmental damage, or lifeline disruption. | Requires state safety inspections and spillway adequacy reviews. |
| Low Hazard Potential | FEMA 93 / 33 U.S.C. § 467(3) | No probable loss of life and low economic losses, principally confined to owner’s land. | Included in NID if physical size thresholds are met. |
| Low-Head Dam (LHDI) | 33 U.S.C. § 467d(g) | River-wide artificial barrier spanning a channel with drop-off between 6 inches and 25 feet. | Cataloged for public hydraulic safety and fish passage barrier mitigation. |
| Satisfactory Condition | USACE / ASDSO Guidance | No recognized safety deficiencies; acceptable performance expected under all loadings. | Routine maintenance required without structural remediation. |
| Poor / Unsatisfactory Condition | USACE / ASDSO Guidance | Safety deficiencies recognized requiring priority engineering remediation or operational restriction. | Informs federal rehabilitation priorities under FEMA grant programs. |
Asset profiles follow a standardized metadata schema recording structural types (earthfill, rockfill, concrete gravity, arch, buttress) and primary purpose codes (flood risk, hydropower, water supply, irrigation).
Where it matters for labs, clinics or supply decisions
For civil engineering labs, environmental researchers, and infrastructure risk analysts, the NID supplies authoritative spatial and structural data. Researchers calculating sediment transport or regional impoundment densities use NID storage-to-height metrics, integrating data into coastal wetland hydrology assessments.
Healthcare facilities and regional emergency planners review NID hazard data during facility siting and contingency planning. Clinical centers situated in mapped flood inundation zones implement elevated emergency power backup and redundant municipal water supplies. Research groups also benefit from open data licensing models that permit automated pipeline ingestion into geographic information systems.
Common misunderstandings
Several frequent misconceptions exist regarding the NID:
- Federal ownership assumption: The federal government does not own most NID dams. Approximately 65% are privately owned, 27% are state or local, and only 3% are federally owned.
- Hazard potential vs. structural condition: “High Hazard Potential” denotes downstream consequences (loss of life if breached), not structural weakness. A newly built, structurally sound dam is classified as high hazard if inhabited structures sit downstream.
- Not a real-time SCADA feed: The NID is a structural registry and GIS database, not a real-time sensor network. Live stage and discharge levels are monitored by local operators and USGS streamgages.
- Farm pond exclusions: The NID excludes small agricultural ponds and weirs under 6 feet tall or under 15 acre-feet storage unless they pose severe downstream hazards.
FAQ
Who maintains the National Inventory of Dams?
The U.S. Army Corps of Engineers (USACE) maintains the NID under 33 U.S.C. § 467d in collaboration with FEMA, state dam safety agencies, and ASDSO.
What physical dimensions qualify a dam for the NID?
Under 33 U.S.C. § 467(3), structures must equal or exceed 25 feet in height with over 15 acre-feet of storage, or equal or exceed 50 acre-feet of storage with height over 6 feet, unless classified as high hazard.
How does hazard potential differ from condition assessment?
Hazard potential measures downstream consequences (potential loss of life or economic loss) if failure occurs. Condition assessment reflects physical structural health and maintenance status (Satisfactory, Fair, Poor, Unsatisfactory).
What is the Low-Head Dam Inventory?
Established under 33 U.S.C. § 467d(g), the LHDI tracks river-wide barriers with drop-offs between 6 inches and 25 feet to mitigate hazardous submerged hydraulic currents and catalog fish passage barriers.
Sources
- Legal Information Institute, Cornell Law School. “33 U.S. Code § 467d – National inventory of dams and low-head dams.” Accessed November 11, 2026. https://www.law.cornell.edu/uscode/text/33/467d.
- Legal Information Institute, Cornell Law School. “33 U.S. Code § 467 – Definitions.” Accessed November 11, 2026. https://www.law.cornell.edu/uscode/text/33/467.
- Normand, Anna E. “Dam Safety Overview and the Federal Role.” Congressional Research Service Report R45981. Updated April 13, 2023. Accessed November 11, 2026. https://www.everycrsreport.com/reports/R45981.html.
- U.S. Army Corps of Engineers. “National Inventory of Dams & Low-Head Dams Inventory.” Accessed November 11, 2026. https://nid.sec.usace.army.mil/.
- Federal Emergency Management Agency. “Federal Guidelines for Dam Safety: Hazard Potential Classification System for Dams.” FEMA Publication 333. Accessed November 11, 2026.







