Written and maintained by CASRAI Editorial Board
Published
On this page
The National Earthquake Hazards Reduction Program (NEHRP) is the coordinated federal framework established by the U.S. Congress under the Earthquake Hazards Reduction Act of 1977 (Public Law 95-124, 42 U.S.C. 7701 et seq.) to reduce earthquake risks to life and property. Lead agency National Institute of Standards and Technology (NIST), the Federal Emergency Management Agency (FEMA), the U.S. Geological Survey (USGS), and the National Science Foundation (NSF) collaborate to translate earth science and structural engineering research into model building codes, seismic hazard maps, and practical risk mitigation practices. For laboratories, healthcare facilities, and academic institutions, NEHRP establishes the foundational standards governing structural seismic design, nonstructural equipment anchorage, hazardous material containment, and automated utility shutoff protocols.
Definition and Scope of NEHRP
Congress enacted NEHRP to establish a long-term, multidisciplinary national strategy for mitigating earthquake hazards. Prompted by catastrophic events including the 1964 Great Alaska earthquake and the 1971 San Fernando earthquake, lawmakers recognized that disaster relief alone could not curb escalating economic and structural losses. Rather than creating a standalone department, NEHRP integrates four existing federal agencies into a cohesive research, monitoring, and implementation partnership.
Statutory milestones have expanded NEHRP’s mission. The 2004 reauthorization (Public Law 108-360) appointed NIST as lead agency, tasking it with overall program coordination and applied engineering measurement. The NEHRP Reauthorization Act of 2018 (Public Law 115-307) authorized $152.1 million annually across partner agencies through FY2023. Critically, Public Law 115-307 expanded the federal objective beyond basic collapse prevention to prioritize post-earthquake functional recovery and reoccupancy time for critical infrastructure.
NEHRP addresses the complete hazard lifecycle: advancing theoretical fault physics in observational seismology and ground motion analysis, operating nationwide seismic networks, developing national hazard models, updating consensus building codes, and providing local mitigation grants.
How NEHRP Works Across Federal Partner Agencies
Section 3 of Public Law 115-307 and 42 U.S.C. 7704 allocate specific statutory roles across the four partner entities:
- NIST (Lead Agency): Directs interagency strategic planning and budget coordination through the Interagency Coordinating Committee (ICC) and Advisory Committee on Earthquake Hazards Reduction (ACEHR). NIST conducts applied measurement science and problem-focused structural research, translating basic engineering breakthroughs into performance-based design standards.
- FEMA (Code Implementation and Education): Converts research into practical tools and model codes. FEMA sponsors the NEHRP Recommended Seismic Provisions for New Buildings and Other Structures (FEMA P-2082), delivers state assistance grants, and publishes operational guidance such as FEMA E-74 (nonstructural mitigation) and FEMA B-526 (earthquake safety checklists).
- USGS (Monitoring and Hazard Mapping): Maintains the Advanced National Seismic System (ANSS), comprising approximately 100 backbone stations, the National Earthquake Information Center (NEIC), and 15 regional seismic networks. USGS publishes the National Seismic Hazard Model (NSHM), operates the ShakeAlert early warning system across California, Oregon, and Washington, and delivers rapid ShakeMap and PAGER event analyses.
- NSF (Basic Research and Infrastructure): Funds fundamental academic research in geosciences, geotechnical engineering, and structural mechanics through the NSF CMMI division programs. NSF supports shared experimental infrastructure within the Natural Hazards Engineering Research Infrastructure (NHERI), maintaining experimental shake tables and archiving open simulation data at the DesignSafe-CI data repository.
What Are Seismic Standards and How Does NEHRP Influence Building Codes?
Seismic standards are engineering design criteria, analytical procedures, and construction specifications developed to ensure buildings withstand lateral ground motion without catastrophic collapse or unacceptable injury. In the United States, seismic standards follow a consensus pipeline originating within NEHRP.
The foundational technical document is the NEHRP Recommended Seismic Provisions for New Buildings and Other Structures, developed under FEMA sponsorship by the Building Seismic Safety Council (BSSC) of the National Institute of Building Sciences (NIBS). The NEHRP Provisions serve as the technical basis for ASCE/SEI 7: Minimum Design Loads and Associated Criteria for Buildings and Other Structures. The International Code Council (ICC) incorporates ASCE 7 into the International Building Code (IBC) and International Existing Building Code (IEBC), which local and state jurisdictions enact into building law.
Modern seismic design is transitioning from traditional collapse prevention to functional recovery, mandated by Section 5 of Public Law 115-307. Functional recovery criteria ensure that critical facilities—such as hospitals, laboratories, and emergency coordination centers—maintain or rapidly regain physical integrity and essential operations following major shaking. Engineers utilize advanced structural modeling frameworks like the OpenSees computational simulation framework to simulate nonlinear structural response and assess functional recovery timelines.
Investing in modern seismic standards yields immense economic dividends. A 2019 National Institute of Building Sciences study determined that adopting modern seismic codes delivers a national average benefit-cost ratio of 12 to 1 (12:1), preventing billions in post-disaster business interruption and rebuilding expenditures.
Which Part of the USA Has the Highest Risk of Earthquakes?
Seismic hazards are unevenly distributed across the United States. According to the USGS National Seismic Hazard Model, nearly 75 percent of the U.S. population lives in regions with potential for damaging ground shaking. Geographic risk profiles vary by tectonic setting:
- Alaska: Represents the nation’s most seismically active zone. The Alaska-Aleutian subduction megathrust produces a magnitude 7.0 or larger earthquake almost annually, and a magnitude 8.0 or greater event every 13 years on average, releasing the vast majority of U.S. seismic energy.
- California: Carries the highest annualized economic risk due to dense urban populations intersecting active strike-slip systems, including the San Andreas, Hayward, Newport-Inglewood, and San Jacinto fault networks.
- Pacific Northwest: The Cascadia Subduction Zone off the coast of Washington, Oregon, and northern California threatens full-margin megathrust ruptures approaching magnitude 9.0, with severe tsunami hazards and widespread coastal subsidence.
- Hawaii: Volcanic tectonic activity and magma migration frequently generate significant tremors exceeding magnitude 6.0 across the island chain.
- Central and Eastern U.S. (Intraplate Faults): The New Madrid Seismic Zone (spanning Missouri, Arkansas, Tennessee, Kentucky, and Illinois) and the Charleston Seismic Zone in South Carolina experience rare but severe intraplate earthquakes. Because the rigid, colder North American cratonic crust transmits seismic waves efficiently, ground shaking covers areas up to ten times larger than comparable western earthquakes.
Overall, 37 U.S. states have experienced magnitude 5.0 or larger earthquakes, underscoring that seismic hazard is a nationwide concern.
What Are the Mitigation Strategies for Earthquakes?
Mitigation strategies encompass structural engineering, nonstructural component bracing, and operational preparedness to prevent structural collapse, avert injuries, and ensure facility survivability. Strategies are categorized into structural and nonstructural disciplines:
- Structural Mitigation: Focuses on the building frame. Key methods include seismic base isolation (uncoupling the foundation using elastomeric or friction pendulum bearings), energy dissipation dampers (fluid viscous or buckling-restrained braces), reinforced concrete shear walls, and ductile framing complying with International Association for Earthquake Engineering guidelines.
- Nonstructural Mitigation: Focuses on architectural finishes, mechanical systems, and laboratory contents. In facilities like research laboratories and hospitals, nonstructural damage accounts for the majority of financial and operational losses during earthquakes. Guidance in FEMA E-74 details the anchoring of ceiling grids, piping manifolds, electrical switchgear, and sensitive instruments.
The following table outlines primary mitigation mechanisms applied in research and critical facility settings:
| Mitigation Domain | Engineering Mechanism | Primary Technical Standard | Primary Failure Mode Prevented | Facility Payoff |
|---|---|---|---|---|
| Structural Isolation | Elastomeric and friction pendulum base isolators | ASCE/SEI 7 Chapter 17 | Lateral acceleration transfer and frame shear | Attenuates ground acceleration to protect superstructures and sensitive imaging instrumentation suites. |
| Structural Bracing | Buckling-restrained braced frames and shear walls | ASCE/SEI 7 Chapter 14 | Excessive inter-story lateral drift and structural collapse | Guarantees building stability and preserves emergency stairwells for safe occupant egress. |
| Equipment Anchorage | Heavy floor anchors and seismic snubbers | FEMA E-74 / ASHRAE | Instrument overturning, walking, and pipe shearing | Secures multi-million-dollar mass spectrometers, electron microscopes, and -80°C ultra-low freezers. |
| Chemical Containment | Shelving retaining lips, latching doors, and secondary containment | NFPA 45 / OSHA HazCom | Reagent bottle shattering and toxic mixing | Prevents chemical spills, hazardous vapor clouds, and laboratory fires during shaking. |
| Lifeline Utilities | Flexible stainless braided joints and automatic shutoff valves | ASCE 25 / ANSI Z21.70 | Gas manifold rupture and water line flooding | Eliminates post-earthquake gas explosions and prevents water damage to cleanroom environments. |
| Early Warning Telemetry | Automated USGS ShakeAlert integration | USGS ANSS Protocol | Uncontrolled operational run during shaking | Parks elevators, isolates toxic pipelines, and suspends automated robotic processes prior to shaking. |
Where It Matters for Laboratories, Research Facilities, and Equipment Protection
Laboratories present distinct operational hazards during earthquakes. Beyond physical building damage, tremors can trigger secondary disasters including chemical spills, biological contamination, cryogenic failures, and loss of longitudinal scientific data. Applying NEHRP and FEMA technical standards is essential to protect personnel and research continuity.
Facility protection prioritizes five core vulnerability areas:
- Chemical Storage and Containment: In accordance with NFPA 45 standards, chemical storage shelves must feature retaining lips (1.5 to 2.0 inches high) or wire barriers to prevent reagent bottles from sliding off. Flammable storage cabinets must be anchored directly into structural wall framing, and incompatible reagents must be isolated in secondary containment basins.
- Cold-Chain and Bio-Repository Security: Freezers operating at -80°C and cryogenic dewars containing vital cell lines or clinical trial specimens must be anchored using certified floor brackets or structural straps. Backup generators supporting cold chains must be mounted on seismic spring isolators equipped with rigid limit snubbers.
- Analytical and Imaging Instrumentation: Heavy, delicate devices—such as nuclear magnetic resonance (NMR) spectrometers, electron microscopes, and high-performance liquid chromatographs—must be secured to prevent walking, tipping, or dislodging optical components.
- Compressed Gas Manifolds: Gas cylinders must be restrained at two points (one-third and two-thirds height) using heavy welded steel chains attached to structural masonry or steel studs, preventing valve shearing and rocket hazards.
- Automated Emergency Utility Shutoffs: Facilities should install ASCE 25-certified seismic gas shutoff valves that automatically isolate natural gas feeds at 0.1g ground acceleration. Connecting building management systems to USGS ShakeAlert early warning feeds enables automated isolation of hazardous exhaust systems before shaking arrives.
What Should I Include in My FEMA Earthquake Checklist?
An effective earthquake safety checklist organizes emergency actions into three sequential phases based on FEMA B-526, FEMA QuakeSmart guidance, and Ready.gov protocols:
- Phase 1: Preparedness and Mitigation (Before an Earthquake)
- Secure Physical Assets: Anchor heavy furniture, biological cabinets, and shelving units to wall framing using structural brackets. Store heavier and hazardous items on bottom shelves.
- Build a 72-Hour Survival Kit: Assemble emergency supplies for at least 72 hours, including 1 gallon of potable water per person per day, non-perishable food rations, NOAA emergency radios, heavy-duty flashlights, comprehensive first-aid kits, essential prescription medications, and portable power banks.
- Create an Emergency Communications Plan: Designate an out-of-area contact person to coordinate family or institutional communication when local telephone networks congest. Identify safe outdoor assembly areas away from facades and power lines.
- Locate and Label Utility Shutoffs: Clearly mark main electrical panels, water supply valves, and gas shutoff valves. Mount a non-sparking shutoff wrench next to the gas meter.
- Enforce Hazardous Material Controls: Secure gas cylinders with dual chains and install retaining lips on all chemical storage shelving.
- Phase 2: Immediate Protective Action (During Shaking)
- Drop, Cover, and Hold On: Immediately Drop to your hands and knees, take Cover beneath a sturdy desk or laboratory bench, and Hold On until shaking stops. Protect head and neck with your arms away from windows, shelving, and heavy suspended fixtures.
- Do Not Run Outside: Stay indoors during shaking; building exteriors present extreme hazards from falling masonry, facade panels, and shattering glass.
- Outdoors: Move into an open space away from buildings, utility poles, and overpasses. Drop to the ground and shield your head until shaking ends.
- Vehicles: Safely pull over away from overpasses and electrical lines, engage the emergency brake, and remain seated with seatbelts fastened.
- Phase 3: Inspection, Damage Assessment, and Recovery (After an Earthquake)
- Check for Injuries and Hazards: Administer emergency first aid. Inspect facilities for chemical spills, fires, and structural damage. Do not strike matches or open flames.
- Inspect Utilities for Leaks: Shut off natural gas if you detect odors, hear hissing, or suspect broken lines. Never attempt to relight gas systems without professional inspection.
- Communicate via SMS: Use text messages instead of voice calls to keep cellular bandwidth available for first responders.
- Prepare for Aftershocks: Anticipate secondary tremors, which can trigger the collapse of damaged structural elements. Enter damaged buildings only after certified engineers complete safety inspections.
Common Misunderstandings About NEHRP and Earthquake Hazards
Common misconceptions obscure public and institutional understanding of earthquake hazards and building regulation:
- Misunderstanding 1: NEHRP enforces building codes nationally. NEHRP is an interagency research and guidance program, not a regulatory authority. Building codes are legally adopted and enforced by municipal and state governments. NEHRP produces resource documents (such as the NEHRP Provisions) that model codes incorporate.
- Misunderstanding 2: Building codes make structures “earthquake proof.” Modern codes are designed primarily to prevent collapse and safeguard life during severe ground motion. A code-compliant building may suffer significant internal structural and architectural damage requiring demolition after an earthquake. NEHRP’s focus on functional recovery addresses this gap.
- Misunderstanding 3: Earthquakes only threaten California and Alaska. While western plate margins experience frequent shaking, 37 U.S. states have experienced magnitude 5.0+ earthquakes. Significant seismic hazards exist across the Central U.S. (New Madrid) and Eastern Seaboard (Charleston).
- Misunderstanding 4: Standing in a doorway is safe. Doorways in modern framed structures provide no structural advantage and expose occupants to swinging doors and flying debris. The verified, universal protection protocol is Drop, Cover, and Hold On beneath a sturdy desk.
- Misunderstanding 5: Earthquakes can be predicted. No scientific organization can predict the exact date, time, and magnitude of an earthquake. USGS models calculate long-term statistical hazard probabilities, while ShakeAlert provides early warning seconds after fault rupture begins.
The data table below summarizes the four statutory NEHRP partner agencies, comparing their core statutory mandates, lead technical focus, annual funding authorizations under Public Law 115-307, key deliverables, and practical facility impacts.
Frequently asked questions
What are the mitigation strategies for earthquakes?
Earthquake mitigation strategies combine structural measures—such as base isolation, shear walls, and buckling-restrained braced frames—with nonstructural protections including equipment floor anchoring, chemical shelf lips, compressed gas cylinder chains, and automatic seismic shutoff valves to prevent structural collapse and secondary disasters.
Which part of the USA has the highest risk of earthquakes?
Alaska experiences the highest frequency of severe earthquakes, averaging a magnitude 7.0 event annually. However, California carries the highest annualized economic risk due to dense population exposure along the San Andreas fault system. The Pacific Northwest, Hawaii, and Central U.S. (New Madrid zone) also face major seismic hazards.
What are seismic standards?
Seismic standards are codified engineering design rules—such as ASCE/SEI 7 and the International Building Code (IBC)—originating from the NEHRP Recommended Seismic Provisions. They govern building framing and nonstructural anchorage to prevent collapse and facilitate rapid post-earthquake functional recovery.
What should I include in my FEMA earthquake checklist?
A FEMA earthquake checklist based on FEMA B-526 covers three phases: preparing 72-hour survival kits, securing heavy equipment, and mapping utility shutoffs before an earthquake; executing Drop, Cover, and Hold On during shaking; and checking for injuries, gas leaks, and utility damage while expecting aftershocks after the event.
What is the primary role of NEHRP in earthquake hazard reduction?
NEHRP coordinates federal earthquake science and mitigation across NIST, FEMA, USGS, and NSF. It translates fundamental earth science and engineering research into national seismic hazard models, model building code updates, early warning systems, and community resilience guidelines.
Sources
- NEHRP: Agencies Working in NEHRP, checked 2026-11-20
- NEHRP: Background and History, checked 2026-11-20
- EveryCRSReport: The National Earthquake Hazards Reduction Program (NEHRP): Overview and Issues for Congress, checked 2026-11-20
- Ready.gov: Earthquakes Preparedness and Safety, checked 2026-11-20
- DesignSafe-CI: About DesignSafe-CI Natural Hazards Engineering Research Infrastructure, checked 2026-11-20
Data: NEHRP Agency Responsibilities, Statutory Mandates, and Laboratory Impact
Comparative statutory breakdown of lead responsibilities, core technical activities, annual funding authorizations under Public Law 115-307, and laboratory infrastructure impacts across the four NEHRP agencies (NIST, FEMA, USGS, NSF).
Period covered: 2019/2026. Coverage: United States.
| Agency | Statutory Role | Lead Focus | Annual Authorization (USD Millions) | Key Technical Outputs | Lab and Facility Impact |
|---|---|---|---|---|---|
| National Institute of Standards and Technology (NIST) | Lead Agency & Interagency Coordinator | Applied structural measurement science and performance-based engineering | 5.9 | Interagency strategic plans, performance-based design standards, disaster resilience frameworks | Develops functional recovery metrics, vibration isolation standards, and performance benchmarks for research buildings. |
| Federal Emergency Management Agency (FEMA) | Implementation & Building Codes Lead | Translating scientific research into model building codes and mitigation tools | 8.76 | NEHRP Recommended Seismic Provisions (FEMA P-2082), FEMA E-74 Nonstructural Mitigation, FEMA B-526 Checklist | Provides anchorage guidelines for chemical hoods, ULT freezers, biological cabinets, and state mitigation grant funding. |
| U.S. Geological Survey (USGS) | Earthquake Monitoring & Hazard Mapping | Seismological monitoring, fault mapping, and real-time hazard delivery | 83.4 | Advanced National Seismic System (ANSS), National Seismic Hazard Model (NSHM), ShakeAlert early warning, ShakeMap | Provides ground acceleration data for local structural codes and real-time telemetry triggering automated utility shutoffs. |
| National Science Foundation (NSF) | Basic Research & Facilities Lead | Fundamental disciplinary research and shared experimental infrastructure | 54 | CMMI research grants, Natural Hazards Engineering Research Infrastructure (NHERI), DesignSafe cyberinfrastructure | Funds basic geotechnical modeling, large-scale shake table testing of structural frames, and open hazard simulation data. |
Sources
- NEHRP Agencies (accessed 2026-11-20)
- EveryCRSReport: NEHRP Overview and Issues for Congress (R43141) (accessed 2026-11-20)
- DesignSafe-CI Cyberinfrastructure (accessed 2026-11-20)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.







