Nitrate Reduction Test: What It Detects and How to Read It

Nitrate reduction test explained: what nitrate broth detects, what colour and zinc results mean, and the cautions that apply.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

General laboratory information for lab and clinic staff, not medical advice and not a bench procedure.

Short answer

The nitrate reduction test shows whether a bacterial isolate can use nitrate (NO3–) as an electron acceptor, a trait carried by the enzyme nitrate reductase. It is run in nitrate broth, and the result is read by detecting nitrite and, if none appears, by checking whether nitrate is still there. It helps separate organisms in an identification panel; it does not confirm an identity on its own.

Definition and scope

ASM Education describes nitrate reduction as mediated by nitrate reductase, indicating that the organism can use nitrate as an electron acceptor during anaerobic respiration. Nitrite, the first product, can be reduced further to NO, N2O, N2 or NH3, depending on the organism’s enzymes and the atmosphere it grows in.

That second point is the reason the test has two readouts rather than one. A tube with no nitrite can mean nitrate was never touched, or that it was used up and carried past nitrite.

How nitrate broth and the test work in practice

Nitrate broth is a simple peptone-and-extract medium with potassium nitrate as the substrate. In HiMedia’s technical data for its Nitrate HiVeg Broth (MV439), the formula is 5.0 g/L peptone, 3.0 g/L extract and 1.0 g/L potassium nitrate at a final pH of 7.0 ± 0.2, and it follows the Society of American Bacteriologists “Pure Culture Study of Bacteria” (1944) formulation, and ISO 7932:1993 also specifies a nitrate medium. The product is intended for detecting nitrate reduction by bacteria in isolated microorganisms.

After incubation, nitrite is detected with sulphanilic acid and alpha-naphthylamine. This is the Griess reaction: nitrite couples to form a red-violet diazonium dye. If no colour appears, zinc dust is used to find out whether nitrate is still in the tube.

How to read the result

Each row follows from the reactions described above.

What is seen What it means
Red-violet colour after the two reagents, before any zinc Nitrate was reduced to nitrite (positive)
No colour with the reagents, then red after zinc Nitrate is still present, so it was not reduced (negative)
No colour with the reagents, and no red after zinc Nitrate was reduced beyond nitrite, to ammonia or nitrogen gas

HiMedia states that nitrate reduction is not a confirmatory test. It also lists these cautions: excess zinc may cause a false negative; the colour with alpha-naphthylamine may fade quickly; and because the test is very sensitive, an uninoculated control tube with the reagents should be used to confirm the medium is nitrite-free. For fast reducers, the read should follow an early incubation, because nitrite may already have been reduced further to nitrogen.

Where it matters for labs

ASM Education lists the test among the biochemical batteries used to separate members of the family Enterobacteriaceae from other gram-negative bacilli, to identify Neisseria species and separate them from Moraxella and Kingella, and to help identify Corynebacterium and other asporogenous gram-positive bacilli. For glucose-fermenting gram-negative bacilli, HiMedia notes that nitrogen gas production is a differential test, and that some non-fermenters can denitrify.

The test sits alongside other basic identification work; see Gram stain reagents and results, what bacteriology covers and the wider microbiology field.

Media quality-control checklist

  • Positive controls: Escherichia coli ATCC 25922, Klebsiella aerogenes ATCC 13048 and Salmonella Typhimurium ATCC 14028, each giving a red-pink colour.
  • Negative control: Acinetobacter calcoaceticus ATCC 19606.
  • Reagent blank: an uninoculated tube with the reagents, expected to be nitrite-free.
  • Storage: dry powder at 10-30 °C, hygroscopic; prepared medium at 15-30 °C.

Handle cultures under your laboratory’s biosafety practice (the BMBL entry explains the national reference). HiMedia gives disposal as autoclaving or incineration per laboratory procedure.

Common misunderstandings

  • “No colour means negative.” Not necessarily. Colourless can mean nitrate was reduced past nitrite, which is why the zinc check exists.
  • “A positive result identifies the organism.” It does not. The manufacturer calls it not confirmatory; it is one trait among several.
  • “Nitrate reduction means producing nitrite.” Nitrite is one possible endpoint; ammonia and nitrogen gas are others.

FAQ

What is nitrate broth used for?

Nitrate broth is the medium in which the nitrate reduction test is run. It supplies potassium nitrate (1.0 g/L in the HiMedia formula) so that a nitrate-reducing organism can convert it, and the products are then looked for with the nitrite reagents.

What does a positive nitrate reduction test mean?

A red-violet colour after the sulphanilic acid and alpha-naphthylamine reagents means the organism reduced nitrate to nitrite, which HiMedia describes as characteristic of Enterobacteriaceae. It is supporting evidence, not a confirmation.

Why is zinc added if the tube stays colourless?

Zinc dust reduces any remaining nitrate to nitrite. Red after zinc means nitrate was still present; no red means the organism had already reduced it beyond nitrite.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Nitrate Reduction Test: What It Detects and How to Read It

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →