Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop pyr test supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

PYR Test: What It Detects, Formats and Quality Control

The PYR test detects pyrrolidonyl peptidase in group A streptococci and enterococci. Read the color reaction, reagent formats and QC checklist.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

The PYR test is a rapid biochemical test that detects pyrrolidonyl peptidase (also called pyrrolidonyl arylamidase), an enzyme found in group A streptococci (Streptococcus pyogenes) and enterococci. A red color after the reagent is added is a positive result. The manufacturer’s instructions describe the test as a presumptive identification, so a positive result is confirmed with further biochemical testing rather than treated as final.

Short answer

PYR stands for L-pyrrolidonyl-beta-naphthylamide, the substrate the test uses. The manufacturer’s instructions for use (IFU) state the intended use as qualitative procedures for rapid presumptive identification of group A streptococci and enterococci. Red means positive; yellow or no color change means negative. The same IFU says PYR is more specific than the routine bacitracin test for group A streptococci and at least as specific as the routine 6.5% NaCl test for enterococci.

What the PYR test detects

The test targets one enzyme activity. Organisms that make pyrrolidonyl peptidase split the PYR substrate, and the reaction releases beta-naphthylamine. When the PYR reagent, N,N-dimethylaminocinnamaldehyde, is added, the released beta-naphthylamine produces a red color. An organism without the enzyme leaves the substrate intact and no red color develops.

The reaction is quick. According to the Remel PYR Reagent IFU (21258), a positive shows red within 1-2 minutes of adding the reagent, and the result is recorded as red for positive and yellow or no color change for negative.

How the PYR test fits into a streptococcal work-up

The test is rarely used alone. The same IFU traces its history: the PYR test was described in 1981 by Godsey, Schulman and Eriquez, and in 1982 Facklam and colleagues used it together with the CAMP and bile esculin tests. Bosley and colleagues read a PYR broth after 4 hours, and Ellner and colleagues used filter-paper strips in which a positive was visible in 15-20 minutes. The PYR Broth IFU (62084) adds that the broth medium was first described in 1970 by Mulczyk and Szewczuk.

For related steps in a work-up, see the CASRAI guides on the bile esculin agar test, the hippurate hydrolysis test, alpha-hemolysis on a blood agar plate, and the broader identifying bacteria overview.

PYR broth, disk and plate formats compared

The reagent IFU lists the formats in which PYR testing is supplied or used. The table summarizes the two IFUs.

Format What the IFU says Source
PYR reagent (developer) N,N-dimethylaminocinnamaldehyde added after PYR hydrolysis; a positive is red within 1-2 minutes. Store at 2-8 °C, protect from light. Remel IFU 21258
PYR broth Described as useful in identifying S. pyogenes, Enterococcus spp. and other gram-positive cocci. The IFU includes a quality-control table for the broth. Remel IFU 62084
PYR/Esculin disk Listed among the formats the reagent is used with. Remel IFU 21258
Strep ID Triplate Listed among the formats the reagent is used with. Remel IFU 21258

Reagent storage and quality control checklist

Quality control is what makes a PYR result trustworthy. The two IFUs together give this checklist:

  • Storage: keep the reagent at 2-8 °C, let it reach room temperature before use, and protect it from light.
  • Discard rules: do not use reagent that has changed color or passed its expiry date. The IFU also says that precipitate formation, or a color shift from yellow to orange-red, is common and does not affect test performance.
  • Control panel: the PYR Broth IFU lists four control organisms. Enterococcus faecalis ATCC 29212 and S. pyogenes ATCC 19615 should be positive; S. agalactiae ATCC 12386 and S. gallolyticus ATCC 9809 should be negative.
  • Aberrant controls: the IFU states that results should not be reported if quality control is aberrant.
  • Intended use: the reagent is for in vitro diagnostic use by trained individuals and is hazardous (an irritant).

The panel checks both directions of the test: two organisms that must turn red and two streptococci that must stay negative.

Where it matters for labs and supply decisions

Laboratories that hold PYR reagent or broth are working with a product whose IFU makes storage temperature, light protection, color change and expiry the grounds for discarding it, and whose quality-control panel needs reference strains to run. A laboratory’s own SOPs and accreditation rules, not this page, set how often controls are run.

What a positive PYR result does not prove

The PYR Broth IFU is direct on this point: a positive PYR test provides a high probability for presumptive identification of enterococci and S. pyogenes, but other organisms, including other gram-positive cocci, may hydrolyze PYR, and further biochemical testing may be necessary for definitive identification. A positive therefore narrows the identification; it does not close it.

Common misunderstandings

  • “Red means group A strep.” Red means pyrrolidonyl peptidase activity. Enterococci also produce it, and so can other gram-positive cocci.
  • “PYR replaces every other test.” The IFU positions PYR as more specific than the bacitracin test, not as a replacement for confirmation, and its own history lists PYR being combined with CAMP and bile esculin testing.
  • “Any color change means a failed reagent.” A shift from yellow to orange-red and precipitate formation are described as common and not affecting performance. A changed color or an expired reagent is a different matter and should not be used.

FAQ

What does a red result on the PYR test mean?

It means the organism hydrolyzed the PYR substrate, releasing beta-naphthylamine, which turns red with the PYR reagent. This is a presumptive identification of group A streptococci or enterococci, to be supported by further biochemical testing.

Is the PYR test positive for group B strep?

No. In the PYR Broth IFU quality-control table, S. agalactiae (group B) ATCC 12386 is the expected negative control.

How long does the PYR test take?

With the reagent IFU, a positive shows red within 1-2 minutes of adding the reagent. The broth format has its own read time, set out in the PYR Broth IFU.

Why does the QC panel include negative controls?

A negative control confirms that the system stays colorless with an organism lacking the enzyme. The IFU’s panel includes S. agalactiae and S. gallolyticus for that purpose.

Sources

  • Thermo Fisher Scientific (Remel), PYR Reagent instructions for use, IFU21258, checked 2026-11-01: documents.thermofisher.com.
  • Thermo Fisher Scientific (Remel), PYR Broth instructions for use, IFU62084 (rev. June 20, 2007), checked 2026-11-01: documents.thermofisher.com.

This page is general product and laboratory information, not a procedure or clinical guidance.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about PYR Test: What It Detects, Formats and Quality Control

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →