Skip to main content
v2026.11,986 entries · CC-BY 4.0

ODB++: What the PCB Data Format Contains and How a Job Is Structured

ODB++ is Siemens EDA’s PCB manufacturing data format: a directory of files for layers, drill, stackup and netlist, with a set of mandatory files.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

ODB++ is a data format for sending a printed circuit board (PCB) design to fabrication, assembly and test. Instead of a loose set of per-layer files, it describes the board as one product model stored as a directory tree of mostly plain-text files: layers, drill data, stackup, netlist, components and bill of materials. Siemens EDA, which maintains it, publishes the specification; whether the format counts as “open” depends on who is describing it.

Definition and scope

Siemens’ ODB++ Design fact sheet (September 2022) defines ODB++ Design as “a PCB product model data format … containing all data necessary to fabricate, assemble and test in a single directory structure.” The same sheet says the format was conceived by Valor, now Siemens EDA, in 1995. Wikipedia adds that the “++” was added in 1997 with component descriptions, that Mentor Graphics acquired Valor in 2010 and that Siemens acquired Mentor in 2016.

The current specification, “ODB++Design Format Specification”, carries the cover label Release 8.1 Update 4, August 2024. Its stated modelling premise is the useful one to remember: “Unlike traditional CAM formats such as Gerber, ODB++ format represents a complete product model rather than a collection of unrelated geometric entities.” In practice that means a receiving application must keep relationships between features, for example that two separate features do not touch, rather than treating each layer as isolated artwork.

ODB++ is a manufacturing-data format for electronics. It is not a general research-data standard, and it is unrelated to bibliographic interchange formats such as the RIS file format, which is also plain-text but serves a different purpose. Research groups meet it when they commission a prototype board, an instrument controller or a sensor carrier from a fabricator and assembler, and the design package has to be handed over without loss.

How an ODB++ job is structured

The specification describes a product model as “an independent and self-contained directory tree.” It gives the reason for choosing a tree over one large file: the structure lets software read or save exactly the part it needs, “avoiding the overhead of reading and writing a large file.” When a model must travel, “standard tar and compression utilities can be used to convert a directory tree into a single flat file.”

Mandatory files

The specification lists five files as mandatory, with everything else included “only when needed”:

  • <product_model_name>/matrix/matrix: its rows give each layer’s type, polarity and context, and it defines the physical order of the layers and the relation of the drill layers.
  • <product_model_name>/misc/info: basic information about the product model, written each time a save is performed. It also carries the model’s default units.
  • <product_model_name>/fonts/standard: the vector definition of every character that can appear in a text feature.
  • <product_model_name>/steps/<step_name>/stephdr: the step header, which includes any step-and-repeat content.
  • <product_model_name>/steps/<step_name>/layers/<layer_name>/features (or features.Z): most of the graphic information for the physical board layers, NC drill and rout layers and drawings.

The data table below compares these five files with the optional ones the specification describes in the same sections: stackup, profile, EDA data and netlist. A “step” is a unit of the job, for example a single board; a product model contains one or more steps, and each step holds its own layers, netlists, EDA data and profile.

Files depend on one another through links defined implicitly in the format. The specification’s example: the file layers/comp_+_top/components links to eda/data, and a layer’s features file links to user-defined symbols stored under symbols. Files that hold measurable entities must carry a UNITS directive, either UNITS=MM or UNITS=INCH, placed before the first line that uses units. If a product model defines no default in misc/info, the default is imperial. Minimum feature resolution is 1/400 micron, and supported coordinates run from (-100, -100) to (100, 100) inches.

Naming and compression rules

Product model, step, layer, symbol and attribute names must be 64 characters or fewer and may contain only lower-case letters a to z, digits and the punctuation marks dash, underscore, dot and plus. They must not start with a dot, hyphen or plus, and must not end with a dot. System attribute names are the one exception to the leading-dot rule. Large files may be stored in standard UNIX compression format (.Z); the specification says compression is optional and that reading software “should expect some files to be compressed (.Z) and some not.”

Stackup: a transition in progress

Release 8.1 Update 4 lists an optional matrix/stackup.xml, which holds the material information required for the complete manufacturing process and “what was previously held in the matrix file.” The specification says it will replace the matrix file in the next major release. Until then the matrix file is required and is the primary source: if the two disagree, the matrix file wins. Siemens’ fact sheet lists stackup layers with copper and dielectric properties among the recent enhancements, alongside flex and rigid-flex definition, intentional shorts and wire bond data.

ODB++ compared with Gerber and IPC-2581

Most pages on this topic are format comparisons, and most are written by tool vendors. The table below records only what each named source says, so you can see where the descriptions come from.

Format How the named source describes its structure Source
ODB++ A directory tree of files forming one product model; tar and compression turn it into a single flat file Siemens specification
ODB++ A CAD-to-CAM format that includes everything in classic Gerber plus data normally sent separately, delivered as a single ZIP file Altium, “ODB++ vs. Gerber X2/X3 vs. IPC-2581”
Gerber X2 Extends RS-274X with layer stack definitions and pad and via attributes; netlists and drill files are still sent separately Altium
Gerber X3 Adds fabrication and assembly data such as reference designators and part numbers in one export package of Gerber files Altium
IPC-2581 A single XML file that can hold the data needed to fabricate and assemble a board Altium

The claims about speed and adoption are contested, so read them with their owners attached. Siemens says a manufacturing package in a legacy format can take a full day to create and validate, against a couple of hours with ODB++, and calls ODB++ “the most widely used intelligent data exchange format in the PCB industry.” Wikipedia reports a fabricator’s comparison of up to 5 hours of planning and tooling with Gerber against about 1 hour with ODB++ for an 8-layer board, and also records the view of Ucamco, which maintains Gerber, that Gerber with X2 attributes is as complete and efficient as ODB++. Altium’s author, writing about industry adoption, called it “nothing short of pathetic” and asked whether monopoly concerns or technical shortcomings were responsible. These are opinions and vendor figures, not measurements this page can confirm.

Where it matters for labs and research hardware

Three details from the primary documents bear directly on a group handing a board design to an outside fabricator or assembler.

  • The sender decides what leaves the building. Siemens says users have “total control of what design content to exclude from the data package.” Its examples: neutralizing net names to protect design intent, or outputting only board layers when a fabricator does not need component-level data.
  • The package can be inspected before it is sent. Siemens provides a free ODB++ Viewer, with which users can view and query design details, measure between PCB objects and locate component placements by name or reference designator.
  • Siemens positions it as a replacement for several outputs. According to the fact sheet, once several designs have been validated, “there will no longer be a need to continue using the legacy format such as Gerber, Excellon, netlist, and BOM outputs.” That is Siemens’ recommendation for its own tools; whether a given fabricator accepts the package is a question for that fabricator.

For how electronic assemblies are checked after fabrication, see the guide to automated optical inspection; for the industry that the data ultimately feeds, see the semiconductor supply chain.

Is ODB++ open or proprietary?

Sources differ, and the difference is mostly about which “open” is meant. Siemens’ fact sheet calls it “an open, ASCII file structure” and points to a free specification download, while adding the heading “Open Format, Yet Controlled IP.” Wikipedia calls it a “proprietary CAD-to-CAM data exchange format,” records past criticism about vendor lock-in and says earlier access required a non-disclosure agreement that Mentor later dropped for the version 7 specification. The specification document itself carries a legal notice stating that its contents are owned by Siemens, that use is limited by the applicable customer agreement or the Siemens Universal Customer Agreement, and that it may not be copied or distributed without written permission. The fact sheet also describes a partner program under which any PCB tools vendor can adopt the format with technical support from Siemens EDA. A readable, downloadable specification and a vendor-controlled licence can both be true at once.

Wikipedia also notes an XML variant, ODB++(X), donated to IPC in 2008 as a step toward merging GenCAM and ODB++ into IPC-2581, and reports it as end-of-life. Wikipedia also describes a 2020 “ODB++ Family” that expanded the format into three connected uses: Design, Process and Manufacturing.

Common misunderstandings

“ODB++ is a single file.”

In the specification it is a directory tree. A single file appears only after tar and compression are applied for transport. Altium describes a ZIP delivery; the specification names tar and compression utilities generally.

“It is a database file.”

The format is a set of text-based files in a defined tree. The specification marks each file’s type, such as Line Record Text, Structured Text or XML, and most are readable as plain text with comment lines beginning with #.

“Newer means every file is in the same state.”

The stackup transition above shows otherwise: a release can add an optional file while the older required one stays authoritative. Anyone writing a reader or checking a package should check which release the specification describes.

“A free spec means a free-for-all.”

A downloadable document does not on its own grant rights to build software on it; the notice on the document refers readers to the applicable licence terms. Treat licensing questions as questions for Siemens, not for a summary page.

“The comparison is settled.”

The speed claims above come from a vendor, a fabricator quoted on Wikipedia and an opposing view from the Gerber maintainer. None of these is an independent benchmark.

Sources

Data: ODB++ product model files: mandatory and optional entries in specification Release 8.1 Update 4

Compiles, from the ODB++Design Format Specification (Release 8.1 Update 4), the file path, whether the specification lists it as mandatory, its text type, whether compression is permitted and what the file holds, for nine product-model files. Rows are limited to files whose entries were read in the specification text.

Period covered: Release 8.1 Update 4 (August 2024).

ODB++ product model files: mandatory and optional entries in specification Release 8.1 Update 4
File path (under /)Status in specificationFile typeCompressionWhat the file holds
matrix/matrixMandatoryStructured TextNoneLayer type, polarity and context per row; physical layer order and drill-layer relations
misc/infoMandatoryLine Record TextNoneBasic product model information, written on every save; holds the default units
fonts/standardMandatoryLine Record TextNoneVector definition of the characters usable in text features
steps//stephdrMandatoryStructured TextNoneStep header, including step-and-repeat content
steps//layers//featuresMandatoryLine Record TextOptional (.Z)Graphic information for board layers, NC drill and rout layers, drawings
matrix/stackup.xmlOptionalXMLNoneMaterial information for manufacturing; will replace the matrix file in the next major release
steps//profileNot in mandatory listStructured TextNoneSingle surface feature outlining the step (board edge), optional internal cutouts
steps//eda/dataNot in mandatory listLine Record TextOptional (.Z)Library of CAD and user-defined component packages, outlines, properties, net connectivity
steps//netlists/cadnet/netlistNot in mandatory listLine Record TextNoneCAD netlist; features without a defined net are assigned NET $NONE$

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about ODB++: What the PCB Data Format Contains and How a Job Is Structured

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →