Written and maintained by CASRAI Editorial Board
Published
On this page
Open channel flow is the flow of a liquid, usually water, with a free surface exposed to atmospheric pressure, so gravity rather than an applied pressure drives it along a stream, ditch, culvert barrel or laboratory flume. Engineers classify it as uniform or non-uniform, steady or unsteady, and subcritical or supercritical, using the Froude number, and they estimate discharge with Manning’s equation.
Definition and scope
In an open channel the water surface is free: the flow depth adjusts to discharge, channel shape, slope and roughness. That is what separates it from pressurised pipe flow, where the conduit is full and pressure carries the water.
The Federal Highway Administration’s roadside-channel manual (HEC-15, third edition, FHWA-NHI-05-114) classifies open-channel flow by three independent conditions, and every analysis starts by deciding which of each pair applies:
- Uniform or non-uniform. In uniform flow, depth and discharge remain constant along the channel.
- Steady or unsteady. In steady flow, no change in discharge occurs over time.
- Subcritical or supercritical. This depends on the Froude number, covered below.
HEC-15 notes that most natural flows are unsteady, because runoff hydrographs rise and fall, but that design practice often treats them as steady and uniform for short periods. That simplification is a modelling choice you should state, not a property of the channel. For the wider water-science context see the CASRAI guide to hydrology and the overview of civil engineering.
Froude number, subcritical and supercritical flow
The Froude number (Fr) is the ratio of inertial to gravitational forces. For a channel it is commonly written Fr = V / √(gD), with V the mean velocity, g gravitational acceleration and D the hydraulic depth. HEC-15 draws the practical distinction:
- Subcritical, Fr below 1.0. “Tranquil” flow: deeper and slower. A small surface wave can travel both upstream and downstream, so downstream conditions can influence the flow upstream.
- Supercritical, Fr above 1.0. “Rapid” flow: shallower with high velocity. A shallow wave moves only downstream, so disturbances cannot travel upstream. HEC-15 says roadside channels with gradients above about 2 percent usually flow supercritical.
- Critical, Fr = 1.0. The boundary between the two; a wave moves only downstream at critical and supercritical flow.
Specific energy and critical depth
FHWA’s archival design-chart publication HDS-3 defines specific energy as the depth plus the velocity head, d + V²/2g, measured from the channel bottom. Critical depth is the depth at which specific energy is a minimum, and it depends only on discharge and channel shape, not on slope or roughness. Ponce’s open-channel hydraulics notes (San Diego State University) likewise identify the minimum of specific energy with the critical state, where F = 1. For a given discharge there are two depths with the same specific energy, one subcritical and one supercritical, which is why the same energy can describe two very different flows.
Manning’s equation and roughness
For uniform flow, HEC-15 gives Manning’s equation (its Eq. 2.1) as Q = (α/n) A R2/3 Sf1/2, where:
- Q is discharge (m³/s in SI, ft³/s in customary units);
- n is Manning’s roughness coefficient (dimensionless);
- A is the flow cross-sectional area;
- R is the hydraulic radius (area divided by wetted perimeter);
- Sf is the friction gradient, which equals the bed gradient So in uniform flow;
- α is a unit constant: 1.0 for SI units and 1.49 for customary units.
Because A and R both depend on depth, the normal depth for a given discharge has to be found by trial and error (HEC-15 Eq. 2.2). Mixing the unit constant with the wrong unit system is a classic source of a roughly 49 percent error, so record which constant a spreadsheet or script uses.
When a constant n stops being reliable
HEC-15 treats n as approximately constant for rigid linings. It stops being constant in very shallow flow, where the roughness height approaches one-tenth of the flow depth or more, and HEC-15 states that a constant n is not acceptable for riprap in small channels. In those cases the roughness has to be treated as a function of depth rather than looked up once.
Gradually varied flow: water surface profiles
Where depth changes slowly along the channel, as upstream of a weir or where the bed slope changes, uniform-flow assumptions no longer hold. Ponce’s notes give the governing relation for gradually varied flow as dy/dx = (S0 − Sf) / (1 − F²) and classify the resulting water surface profiles into twelve types (families such as M for mild slopes and S for steep slopes). Two step methods are used to compute them:
- Direct step: for prismatic channels, with depth as the independent variable.
- Standard step: for any channel, with distance along the channel as the independent variable. Ponce notes this is the approach used in HEC-RAS.
Rapidly varied flow: the hydraulic jump
FHWA’s energy-dissipator manual (HEC-14, third edition, FHWA-NHI-06-086, Chapter 6) describes the hydraulic jump as occurring “when supercritical flow is forced to change to subcritical flow by an obstruction to the flow.” The change is accompanied by considerable turbulence and loss of energy: specific energy falls across the jump as depth increases. HDS-3 adds the general rule that supercritical flow can be changed to subcritical flow only by passing through a hydraulic jump.
HEC-14, citing the U.S. Bureau of Reclamation (USBR, 1987), relates the form of the jump to the upstream Froude number. The data table below this article sets out the ranges and the energy loss each source states. Three practical points follow from it. First, a jump cannot form at Fr = 1.0. Second, in the oscillating range (Fr from 2.5 to 4.5) the incoming jet alternates between the bottom and the surface, producing surface waves that can cause erosion downstream. Third, culvert outlet Froude numbers often fall between 1.5 and 4.5, which is why that part of the table matters for outlet design.
For a horizontal channel, HEC-14 balances momentum across the jump (its Eq. 6.1): Q²/(gA1) + A1Y1 = Q²/(gA2) + A2Y2, where Y is the depth to the centroid of the flow area and subscripts 1 and 2 mean before and after the jump. HEC-14 treats a channel as horizontal up to a slope of 18 percent (about 10 degrees).
Which method for which flow condition
| Flow condition | Governing idea or equation | Source |
|---|---|---|
| Uniform, steady flow | Manning’s equation, with Sf equal to bed gradient; normal depth by trial and error | HEC-15, section 2.1 |
| Gradually varied flow, prismatic channel | Direct step method, depth as independent variable | Ponce, ch. 7 |
| Gradually varied flow, any channel shape | Standard step method, distance as independent variable | Ponce, ch. 7 |
| Rapidly varied flow, hydraulic jump | Momentum balance across the jump; jump form from upstream Froude number | HEC-14, ch. 6 |
| Critical depth or minimum specific energy | Depends only on discharge and channel shape | HDS-3 |
Where it matters for field channels and laboratory studies
Field roadside and drainage channels, culvert outlets and constructed channels are the settings in which the FHWA manuals apply these relationships, and the same classification carries over to laboratory flumes and numerical models: decide steady or unsteady, uniform or not, and sub- or supercritical before choosing an equation. Two practical consequences follow from the sources above. A reported Manning’s n is only meaningful with the unit constant and the depth range it was determined for. And a computed Froude number near the 1.0 boundary deserves caution, because the regime, and therefore the direction in which disturbances travel, changes there. If your measurements or model runs feed a shared dataset, the hydrology data repository guide explains how to document and share them. Related process-oriented pages include sedimentology, where flow regime controls sediment transport, and fish passage, where culvert hydraulics are a design concern. The wider field is described on the civil and structural engineering discipline page.
Common misunderstandings
- “Fast” does not mean supercritical. Criticality depends on the Froude number, which combines velocity and depth. A deep, fast channel can still be subcritical.
- Manning’s n is not a fixed material property. HEC-15 shows it can change with depth, notably in shallow flow and over riprap.
- Uniform flow is an idealisation. Natural flows are mostly unsteady, and a channel treated as uniform and steady is an assumption made for a short period.
- A jump is not a failure of the flow. HEC-14 treats a hydraulic jump as a way to dissipate energy at hydraulic structures when properly designed, though poorly controlled jump forms can cause downstream erosion.
- The step methods are not interchangeable in scope. The direct step method is for prismatic channels; the standard step method handles any channel.
Frequently asked questions
What is open channel flow?
It is flow of a liquid with a free surface exposed to the atmosphere, driven by gravity along a channel, as opposed to a conduit flowing full under pressure.
What is the difference between subcritical and supercritical flow?
Subcritical flow has a Froude number below 1.0 and is deeper and slower; supercritical flow has a Froude number above 1.0 and is shallower and faster (HEC-15).
What does Manning’s equation calculate?
It gives the discharge of uniform open-channel flow from the roughness coefficient, flow area, hydraulic radius and friction gradient, with a unit constant of 1.0 for SI and 1.49 for customary units (HEC-15).
When does a hydraulic jump form?
When supercritical flow is forced to become subcritical, for example by an obstruction. It cannot form at a Froude number of 1.0, and HEC-14 reports typical energy loss of 45 to 70 percent for stable jumps at Froude numbers of 4.5 to 9.0.
Sources
- Federal Highway Administration, Design of Roadside Channels with Flexible Linings, HEC-15, 3rd ed., FHWA-NHI-05-114, 2005. https://www.fhwa.dot.gov/engineering/hydraulics/pubs/05114/05114.pdf (read 2026-11-15).
- Federal Highway Administration, Hydraulic Design of Energy Dissipators for Culverts and Channels, HEC-14, 3rd ed., FHWA-NHI-06-086, chapter 6. https://www.fhwa.dot.gov/engineering/hydraulics/pubs/06086/hec14.pdf (read 2026-11-15).
- Federal Highway Administration, Design Charts for Open-Channel Flow, HDS-3 (archival). https://www.fhwa.dot.gov/engineering/hydraulics/pubs/hds3.pdf (read 2026-11-15).
- J. M. Ponce, Open Channel Hydraulics, chapters 3 and 7, San Diego State University. https://ponce.sdsu.edu/open_channel_hydraulics_03.php and https://ponce.sdsu.edu/open_channel_hydraulics_07.php (read 2026-11-15).
Data: Hydraulic jump form, effect and energy loss by upstream Froude number
Compiled from FHWA HEC-14 chapter 6, which reports U.S. Bureau of Reclamation (1987) jump forms by upstream Froude number. Each row gives the Froude range, the jump form, the downstream behaviour the manual describes, and the energy loss where the manual states one.
Period covered: 2006.
| Upstream Froude number range | Jump form | Behaviour described in HEC-14 | Energy loss (percent) |
|---|---|---|---|
| 1.0 | No jump forms | Flow is at critical depth | not applicable |
| 1.0 to 1.7 | Slight surface disturbance | Upstream flow only slightly below critical depth; near 1.7 downstream depth is about twice incoming depth and exit velocity about half | not stated |
| 1.7 to 2.5 | Pre-jump with roller | Roller begins and intensifies with Froude number; smooth surface and uniform velocity | about 20 |
| 2.5 to 4.5 | Oscillating jump | Incoming jet alternates between bottom and surface; surface waves can cause downstream erosion | not stated |
| 4.5 to 9.0 | Stable, well-balanced jump | Turbulence mostly confined to the jump; comparatively smooth downstream surface | 45 to 70 |
| above 9.0 | Highly efficient jump | Rough water surface may cause downstream erosion | not stated |
Sources
- HEC-14 Hydraulic Design of Energy Dissipators for Culverts and Channels, 3rd ed., chapter 6 (accessed 2026-11-15)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.