Written and maintained by CASRAI Editorial Board
Published
On this page
A petroleum ether safety data sheet (SDS) details the hazard profile, personal protective equipment (PPE), exposure limits, and engineering controls required to handle volatile aliphatic hydrocarbon solvent mixtures safely. Despite its traditional trade name, petroleum ether contains no ether functional groups (C-O-C) and is classified under the Globally Harmonized System (GHS) and OSHA Hazard Communication Standard (29 CFR 1910.1200) as a flammable liquid (Category 1 or Category 2, H224 or H225), an aspiration hazard (Category 1, H304), a skin irritant (Category 2, H315), a central nervous system depressant (STOT SE 3, H336), and an aquatic environmental toxicant (Chronic Category 2, H411). Because commercial petroleum ether cuts have closed-cup flash points as low as -40 °C to -57 °C and generate heavy vapors that travel along floors, regulatory compliance demands storage in NFPA 30-compliant flammable cabinets, grounded and bonded metal dispensing containers, certified chemical fume hoods, and heavy nitrile or Viton gloves rather than thin disposable examination gloves.
Definition, Chemical Composition, and Regulatory Scope
Petroleum ether is a non-polar solvent blend composed of volatile, low-molecular-weight aliphatic hydrocarbons distilled from crude petroleum. The solvent is marketed under several historical synonyms, including petroleum spirit, petroleum benzin, light ligroin, refined solvent naphtha, and varnish makers’ and painters’ (VM&P) naphtha. From a chemical perspective, petroleum ether is not a chemical ether; it does not possess an oxygen atom bridging two alkyl or aryl groups. Instead, it consists of saturated straight-chain, branched, and cyclic hydrocarbons—primarily pentanes (C5H12), hexanes (C6H14), and heptanes (C7H16)—distilled within specific temperature boundaries.
In occupational chemical registries and regulatory databases, petroleum ether is primarily cataloged under two major registry numbers:
- CAS Registry Number 8032-32-4: Historically assigned to ligroin, petroleum ether, and VM&P naphtha fractions, representing light petroleum distillates with boiling points between 30 °C and 120 °C.
- CAS Registry Number 64742-49-0: Designated under modern European and international conventions as hydrocarbons, C6-C7, n-alkanes, isoalkanes, cyclics, containing less than 5% n-hexane by weight.
Under the Occupational Safety and Health Administration (OSHA) Hazard Communication Standard (29 CFR 1910.1200), chemical manufacturers and distributors must provide a standardized 16-section safety data sheet. Laboratory personnel, principal investigators, and Environmental Health and Safety (EHS) officers consult these sheets to establish standard operating procedures (SOPs), select exposure control systems, and design hazardous waste collection protocols. Understanding how to navigate the 16-section structure is foundational; researchers can consult CASRAI’s reference on how to read a safety data sheet to cross-reference mandatory section alignments from product identification (Section 1) to regulatory compliance (Section 15).
Laboratory and Industrial Applications in Practice
Because of its non-polar character, low boiling point, and rapid evaporation rate without non-volatile residue, petroleum ether is widely employed across analytical, synthetic, and industrial facilities:
- Natural Product and Lipid Extraction: Petroleum ether serves as the primary extraction medium for isolating non-polar lipids, oils, waxes, and fats from biological tissues, agricultural crops, and foodstuffs. The low boiling range facilitates solvent recovery via rotary evaporation without subjecting heat-sensitive phytochemicals or triglycerides to thermal degradation.
- Liquid Chromatography and Flash Purification: In preparative column chromatography, petroleum ether is utilized as the weak, non-polar mobile phase component. Method developers frequently pair it with moderately polar eluting solvents, such as ethyl acetate, to separate reaction crude mixtures. When establishing chromatography protocols, lab staff should review the corresponding ethyl acetate SDS to balance polarity adjustments against combined solvent vapor pressures.
- Recrystallization and Bench Washing: In organic synthesis, petroleum ether is used as an anti-solvent or non-polar wash to precipitate purified organic compounds from more polar mother liquors, rinsing away lipophilic reaction by-products.
- Industrial Degreasing and Surface Preparation: Manufacturing facilities use technical petroleum ether cuts to clean precision metal components, optical assemblies, and electronic substrates, relying on fast drying cycles.
The grade of petroleum ether determines the stringency of manufacturing controls, residual impurities, and solvent consistency. Analytical laboratories handling trace spectroscopy or high-performance chromatography must evaluate how specifications differ between technical cuts and certified analytical reagents, as detailed in CASRAI’s analysis of chemical grades ACS, USP, reagent, and technical.
Commercial Boiling Ranges, Solvent Fractions, and Physical Specifications
Unlike single-component organic solvents such as toluene or acetone, petroleum ether does not exhibit a single boiling point. Instead, it evaporates across distinct boiling cuts determined during fractional distillation. Manufacturers fractionate petroleum ether into tight boiling ranges tailored for specific experimental workflows:
- 30–60 °C Fraction (Light Cut): Composed predominantly of pentane isomers (n-pentane, isopentane). This cut is favored when rapid solvent evaporation at room temperature is required or when concentrating volatile analytes.
- 40–60 °C Fraction (Standard ACS Reagent Grade): The most common analytical formulation, containing pentanes and hexanes. It balances evaporation velocity with manageable benchtop retention in reflux condensers.
- 60–80 °C Fraction (Hexane Fraction): Dominated by hexane isomers. While offering higher thermal stability in extraction baths, cuts within this range require rigorous monitoring for n-hexane content.
- 80–100 °C and 100–120 °C Fractions (Heavy Ligroin): Formulated with heptane and octane isomers, these fractions are applied in higher-temperature extractions and industrial solvent degreasing.
To inspect specific thermodynamic boundaries, boiling curves, and laboratory solvent behaviors across these thermal fractions, researchers should consult CASRAI’s technical analysis of petroleum ether boiling point.
The physical properties disclosed across Sections 9 of manufacturer SDSs reveal key behavioral hazards:
- Specific Gravity / Density: Typically ranges between 0.64 and 0.66 g/cm³ at 20 °C. Petroleum ether is significantly lighter than water and will float on aquatic surfaces, precluding water-based extinguishing techniques during fire emergencies.
- Vapor Density: Disclosed at approximately 2.5 (relative to air = 1.0). Petroleum ether vapors are two and a half times heavier than air. During benchtop handling, dispensing, or accidental spills, vapors do not rise to ceiling exhaust vents; they sink to floor level, accumulate in trenches or lower shelves, and travel substantial distances across laboratory floorboards toward ignition sources.
- Water Solubility: Immiscible with water (solubility under 0.1 g/L at 20 °C). In contrast, it is miscible with ethanol, diethyl ether, chloroform, and benzene.
- Evaporation Rate: High relative to butyl acetate (> 10), contributing to rapid atmospheric vapor accumulation upon container opening.
The comparative data table below outlines the physical parameters, closed-cup flash points, autoignition thresholds, and regulatory flammability classifications across standard petroleum ether boiling cuts.
Petroleum Ether Hazards and GHS Classification
Safety Data Sheets authored under the United Nations Globally Harmonized System (GHS) disclose health, physical, and environmental hazard classes in Section 2. Evaluation of safety data sheets from major manufacturers—including Thermo Fisher Scientific (Catalog E139), MilliporeSigma (Product 32299), and Carl Roth (Article T173)—demonstrates a unified profile of acute and chronic hazard classifications:
- Physical Hazard: Flammable Liquid (Category 1 or Category 2): Fractions with initial boiling points equal to or below 35 °C are classified as Flammable Liquid Category 1 (H224: Extremely flammable liquid and vapor). Standard ACS fractions with initial boiling points above 35 °C and flash points below 23 °C are classified as Flammable Liquid Category 2 (H225: Highly flammable liquid and vapor). Laboratories handling broader solvent inventories can compare these stringent classifications with the handling controls described for a flammable liquid category 3.
- Health Hazard: Aspiration Toxicity (Category 1, H304): “May be fatal if swallowed and enters airways.” If petroleum ether liquid is swallowed and enters the trachea—either directly or during regurgitation—its low viscosity and low surface tension allow it to disperse rapidly into pulmonary alveoli. This causes acute chemical pneumonitis, severe pulmonary edema, bronchial hemorrhage, and tissue necrosis. Ingestion must never be treated with induced vomiting.
- Health Hazard: Skin Corrosion / Irritation (Category 2, H315): “Causes skin irritation.” As an aggressive defatting agent, petroleum ether dissolves epidermal lipid layers, leading to redness, cracking, severe localized dermatitis, and increased vulnerability to secondary cutaneous infections.
- Health Hazard: Specific Target Organ Toxicity – Single Exposure (STOT SE 3, H336): “May cause drowsiness or dizziness.” Inhalation of concentrated aliphatic vapors produces central nervous system (CNS) depression, manifesting as lightheadedness, headache, cognitive blunting, uncoordinated motor function, and potential loss of consciousness at higher vapor fractions.
- Environmental Hazard: Chronic Aquatic Toxicity (Category 2, H411): “Toxic to aquatic life with long lasting effects.” Low-solubility aliphatic hydrocarbons partition into sediment and bioaccumulate in aquatic organisms, making sewer disposal illegal and environmentally catastrophic.
- Chronic / Impurity Hazards (Germ Cell Mutagenicity H340 and Carcinogenicity H350): Under EU CLP and OSHA regulations, petroleum feedstocks containing 0.1% or greater benzene by weight carry mandatory Carcinogenicity Category 1B and Mutagenicity Category 1B warnings. Certified ACS Reagent grades restrict benzene to trace levels (typically under 0.001% to 0.01%), eliminating the H340/H350 designation on high-purity analytical certificates.
The GHS signal word for petroleum ether is Danger. Standard SDSs display four distinct GHS pictograms: the Flame (GHS02), the Health Hazard (GHS08), the Exclamation Mark (GHS07), and the Environment (GHS09).
Petroleum Ether Flash Point and Flammability Properties
The flash point represents the lowest liquid temperature at which a chemical produces sufficient vapor above its surface to form an ignitable mixture with air. Petroleum ether exhibits an exceptionally low closed-cup flash point, typically reported between -40 °C and -57 °C (-40 °F to -70 °F) for low-boiling analytical fractions (such as 30–60 °C or 40–60 °C). Even heavy ligroin cuts retain flash points well below ambient laboratory temperatures.
Because typical laboratory working spaces operate between 18 °C and 25 °C, petroleum ether is permanently stored and handled at temperatures far exceeding its flash point. At all operational temperatures, the liquid continuously emits vapor in concentrations capable of immediate ignition upon contacting a spark, hot surface, or electrostatic arc.
Flammability parameters detailed in Section 9 of the SDS include:
- Lower Explosive Limit (LEL): 1.1% by volume in air. A vapor concentration of just 11,000 ppm is sufficient to sustain flame propagation.
- Upper Explosive Limit (UEL): 5.9% by volume in air (reaching up to 8.0% in specific branched formulations).
- Autoignition Temperature: 240 °C to 288 °C (464 °F to 550 °F). While open flames represent the most visible threat, contact with hotplates, heating mantles, uninsulated steam lines, or overheated stirrers can trigger spontaneous vapor ignition without any spark.
- Electrostatic Accumulation: Pure aliphatic hydrocarbons possess extremely low electrical conductivity (often below 100 pS/m). When petroleum ether flows through piping, pours through funnels, or sloshes in carboys, static electrical charges accumulate within the liquid. If the container is not electrically grounded and bonded, the electrostatic potential can discharge as a visible spark, igniting surrounding vapors.
Occupational Exposure Limits and Personal Protective Equipment (PPE)
Engineering controls and personal protective equipment must be calibrated against regulatory occupational exposure limits (OELs) established by federal agencies and industrial hygiene bodies. Section 8 of the SDS discloses the following airborne thresholds:
- OSHA Permissible Exposure Limit (PEL): 500 ppm (2,000 mg/m³) as an 8-hour time-weighted average (TWA) under 29 CFR 1910.1000 Table Z-1 (Petroleum distillates / naphtha).
- NIOSH Recommended Exposure Limit (REL): 350 mg/m³ (approximately 86 ppm) as a 10-hour TWA workday, supplemented by a 15-minute Ceiling limit of 1,800 mg/m³ (approximately 444 ppm).
- NIOSH Immediately Dangerous to Life or Health (IDLH): 1,000 ppm.
- ACGIH Threshold Limit Value (TLV): 300 ppm (8-hour TWA) for VM&P naphtha fractions.
Engineering controls must always serve as the primary barrier against exposure. Petroleum ether must be handled exclusively within an operational, certified chemical fume hood providing an average face velocity of 80 to 100 feet per minute (fpm). Open-bench pouring, heating, or evaporating is prohibited under institutional chemical hygiene plans.
Where personal protective equipment is specified, laboratory personnel must observe rigorous material compatibility standards:
- Chemical-Resistant Gloves: Standard 4-mil disposable nitrile examination gloves provide protection against minor accidental droplets only. Standard ASTM F739 chemical permeation testing demonstrates that petroleum ether permeates thin nitrile rapidly—often within 15 to 30 minutes—causing swelling, softening, and barrier failure. For intentional contact, total immersion, or bulk decanting, personnel must wear heavy unsupported nitrile gauntlets (thickness ≥ 15 mil, breakthrough time > 480 minutes) or Viton fluorocarbon elastomer gloves (breakthrough time > 480 minutes). Neoprene provides fair short-term resistance (approx. 99 minutes breakthrough). Natural rubber (latex) and polyvinyl chloride (PVC) gloves degrade rapidly and must never be worn.
- Eye and Face Protection: Chemical splash goggles conforming to ANSI Z87.1 must be worn to seal against volatile vapor penetration and liquid splashes. When transferring volumes greater than 1 L, workers must supplement goggles with a full-face shield.
- Body Protection: 100% cotton or static-dissipative laboratory coats are required. Synthetic fiber coats (polyester or nylon) generate electrostatic charges during movement and melt upon flash-fire exposure, exacerbating burn trauma.
- Respiratory Protection: If engineering fume hoods are unavailable or during emergency spill containment exceeding the NIOSH REL, workers must wear a NIOSH-approved half-mask or full-face air-purifying respirator fitted with organic vapor (OV) cartridges up to 1,000 ppm, or a supplied-air respirator for higher concentrations.
Safe Handling Protocols and Petroleum Ether Storage
Safe storage of petroleum ether is strictly regulated under OSHA 29 CFR 1910.106 and National Fire Protection Association (NFPA) standards:
- NFPA 30 Flammable Liquid Classification: Petroleum ether fractions with boiling points below 37.8 °C (100 °F) and flash points below 22.8 °C (73 °F) are classified as Class IA Flammable Liquids. Fractions with boiling points at or above 37.8 °C (such as 40–60 °C or 60–80 °C cuts) are classified as Class IB Flammable Liquids. Both classes represent the highest tiers of fire danger.
- Flammable Storage Cabinets: Storage must take place within dedicated, UL-listed or FM-approved flammable liquid storage cabinets built in accordance with NFPA 30 Section 9.5 and OSHA 29 CFR 1910.106(d)(3). Cabinets must feature double-walled 18-gauge sheet steel construction with a 1.5-inch insulating air space, three-point latching doors, and liquid-tight bottom sills raised at least 2 inches to contain internal leaks. The total quantity of Class I and Class II flammable liquids stored inside a single cabinet must not exceed 60 gallons (227 L).
- Electrical Bonding and Grounding: Under OSHA 29 CFR 1910.106(e)(6)(ii), whenever petroleum ether is dispensed or transferred from one metallic vessel to another (such as from a 20-liter drum into a stainless steel carboy), both containers must be electrically bonded and connected to an approved earth ground. This prevents static potential differences from creating an incendiary spark across the liquid stream.
- Absolute Refrigeration Restrictions: Domestic, household-style refrigerators or standard laboratory cold rooms must NEVER be used to store petroleum ether. In domestic units, internal mechanical thermostats, automatic defrost timers, interior light switches, and circulating fans generate electrical arcs during normal cycling. When petroleum ether containers breathe or leak, heavier-than-air vapors accumulate in the lower crisper compartments. The next thermostat cycle inevitably detonates the vapor cloud, causing catastrophic laboratory explosions. If cold storage is technically necessary, the solvent must reside exclusively in specialized refrigerators certified under NFPA 45 as flammable-safe or explosion-proof.
- Chemical Incompatibilities (Section 10): Petroleum ether reacts vigorously with strong oxidizing agents, including fuming nitric acid, concentrated hydrogen peroxide, perchlorates, chromic acid, and liquid oxygen. Contact with halogens (fluorine, chlorine, bromine) can trigger spontaneous, highly exothermic substitution reactions accompanied by fire or detonation.
Spill Control, Environmental Precautions, and Petroleum Ether Disposal
Emergency spill response protocols outlined in Section 6 of the SDS require immediate and disciplined execution:
- Immediate Evacuation and Ignition Isolation: In the event of a benchtop or floor spill, immediately extinguish all nearby flames, switch off unsealed electrical devices, and instruct personnel to evacuate the vapor dispersion zone. If safe to do so, activate emergency ventilation to exhaust vapors outside the facility.
- Absorbent Containment: Personnel donning appropriate PPE (chemical splash goggles, Viton or heavy nitrile gauntlets, and an organic vapor respirator) must contain the spill using inert, non-combustible absorbents. Suitable materials include vermiculite, diatomaceous earth, bentonite clay, or polypropylene oil-only absorbent pads. Flammable organic absorbents such as sawdust, paper towels, or cellulose must never be applied to Class I flammable liquids.
- Non-Sparking Tools: Sorbent saturated with petroleum ether must be gathered using non-sparking brass, aluminum, or conductive polypropylene scoops. Metallic steel shovels or scrapers can generate friction sparks capable of igniting residual vapors. Sorbent is placed into an airtight, vapor-tight steel waste drum lined with antistatic bagging, labeled, and sealed.
- Environmental Protection: Prevent the liquid from entering storm drains, sanitary sewer lines, sumps, or basement crawlspaces. Because petroleum ether floats on water and possesses an explosive vapor envelope, solvent reaching sewer infrastructure can migrate to municipal treatment plants and trigger subterranean vapor explosions.
- EPA RCRA Hazardous Waste Classification: Under the Resource Conservation and Recovery Act (RCRA, 40 CFR Part 261), spent petroleum ether and contaminated spill cleanup debris are classified as D001 Hazardous Waste due to the characteristic of ignitability (flash point below 60 °C / 140 °F under 40 CFR 261.21). If chemical analysis or refinery disclosures reveal benzene concentrations equal to or exceeding 0.5 mg/L via the Toxicity Characteristic Leaching Procedure (TCLP), EPA Waste Code D018 (Benzene) also attaches to the waste stream. Waste must be consigned to a licensed hazardous waste treatment, storage, and disposal facility (TSDF) for high-temperature incineration or solvent fuel blending; drain disposal is strictly illegal.
Common Misunderstandings Regarding Petroleum Ether
Misinterpretations of petroleum ether’s terminology and hazard profile create recurring vulnerabilities in academic and industrial laboratories:
- Misunderstanding 1: Petroleum Ether is a Chemical Ether: Because of the word “ether” in its trivial name, students and researchers frequently assume the solvent possesses a C-O-C dialkyl ether structure similar to diethyl ether or tetrahydrofuran. In reality, the name derives from historical 19th-century usage denoting any light, ethereal, volatile fluid derived from petroleum. It is an alkane mixture possessing chemical reactivity distinct from true ethers.
- Misunderstanding 2: Petroleum Ether Forms Explosive Peroxides on Storage: True organic ethers (such as diethyl ether, diisopropyl ether, and dioxane) react with atmospheric oxygen via free-radical autoxidation at alpha C-H bonds, generating shock- and friction-sensitive organic peroxides. Because pure aliphatic hydrocarbons lack ether oxygen atoms, petroleum ether does not undergo ethereal autoxidation to form organic peroxides during shelf storage. Routine peroxide test-strip screening—essential for diethyl ether—is unnecessary for standard petroleum ether inventory, provided it is not contaminated with peroxide-forming compounds.
- Misunderstanding 3: Disposable Examination Gloves Provide Adequate Benchtop Barrier: Lab personnel routinely handle petroleum ether while wearing 3-mil or 4-mil disposable nitrile examination gloves, assuming the nitrile barrier guarantees chemical protection. However, light aliphatic hydrocarbons diffuse rapidly through thin polymer matrices. Saturated disposable gloves trap volatile solvent against warm skin, accelerating epidermal defatting and chemical dermatitis while giving the user a false sense of security. Heavyweight nitrile or Viton must be selected whenever contact is anticipated.
- Misunderstanding 4: Standard Household Refrigerators are Acceptable for Chilled Storage: Uninformed personnel sometimes place volatile solvent containers into standard kitchen-style refrigerators to minimize evaporation losses. As noted in NFPA 45, the internal arc generated by ordinary thermostats makes household refrigerators explosive traps for low-flash-point solvents. Cold storage requires dedicated, certified flammable-safe refrigeration infrastructure.
Frequently asked questions
What is the difference between petroleum ether and diethyl ether on an SDS?
While diethyl ether (CAS 60-29-7) is a specific chemical compound containing a central oxygen atom bonded to two ethyl groups (C2H5-O-C2H5), petroleum ether (CAS 8032-32-4 / 64742-49-0) is an alkane hydrocarbon mixture without oxygen. On a safety data sheet, diethyl ether carries distinct warnings for organic peroxide formation upon air exposure (EUH019) and acute oral toxicity (H302), whereas petroleum ether is categorized as an aspiration hazard (H304) and chronic aquatic toxicant (H411).
Why is petroleum ether classified as an aspiration hazard (H304)?
Petroleum ether exhibits very low kinematic viscosity (well below 20.5 mm²/s at 40 °C) and low surface tension. If ingested, liquid easily creeps past the epiglottis into the trachea and bronchial tree during swallowing or vomiting. Once inside pulmonary tissue, the aliphatic solvent strips surfactant proteins from alveolar walls, causing severe chemical pneumonitis, pulmonary hemorrhage, and acute respiratory failure. First aid protocols strictly forbid inducing vomiting.
What is the flash point of petroleum ether, and how does it affect laboratory safety?
Standard laboratory petroleum ether cuts have closed-cup flash points ranging from -40 °C to -57 °C (-40 °F to -70 °F). Because this temperature is vastly lower than ambient room temperature, the solvent continuously generates ignitable vapor-air mixtures under all normal handling conditions. Strict elimination of ignition sources, static bonding and grounding, and active chemical fume hood exhaust are mandatory.
Can standard disposable nitrile gloves be used when handling petroleum ether?
Thin disposable nitrile examination gloves (4 mil) provide splash protection only and fail rapidly under continuous contact, exhibiting breakthrough times under 15 to 30 minutes accompanied by noticeable polymer swelling. For decanting, parts washing, or extended immersion, safety data sheets require heavy unsupported nitrile gauntlets (≥ 15 mil) or Viton fluorocarbon gloves, which provide normalized breakthrough times exceeding 480 minutes.
What storage class and cabinet requirements apply to petroleum ether under NFPA 30?
Petroleum ether cuts boiling below 37.8 °C are designated as NFPA 30 Class IA Flammable Liquids, while cuts boiling at or above 37.8 °C are Class IB Flammable Liquids. Both classes must be stored inside certified flammable liquid storage cabinets constructed with double-walled 18-gauge sheet steel and 1.5 inches of insulating airspace. Total Class I liquid storage must not exceed 60 gallons per cabinet.
How must spent petroleum ether be classified and packaged for chemical waste disposal?
Spent petroleum ether must be collected in dedicated, grounded metal or antistatic safety waste containers as a non-halogenated organic solvent. Under EPA RCRA regulations, it is designated as D001 hazardous waste (ignitability) and may carry D018 (benzene toxicity) if feedstock benzene levels exceed 0.5 mg/L. It is strictly prohibited from sanitary drain disposal and must be routed to a licensed facility for high-temperature thermal destruction or fuels blending.
Sources
- National Institute for Occupational Safety and Health (NIOSH): Pocket Guide to Chemical Hazards – VM & P Naphtha (CAS 8032-32-4). https://www.cdc.gov/niosh/npg/npgd0496.html (accessed 2026-11-16)
- Occupational Safety and Health Administration (OSHA): 29 CFR 1910.106 Flammable Liquids Standard. https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.106 (accessed 2026-11-16)
- Occupational Safety and Health Administration (OSHA): 29 CFR 1910.1200 Appendix D Safety Data Sheets. https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1200AppD (accessed 2026-11-16)
- Thermo Fisher Scientific: Safety Data Sheet – Petroleum Ether ACS (Catalog E139-4). https://www.fishersci.com/store/msds?partNumber=E1394&productDescription=PETROLEUM+ETHER+ACS+4L&vendorId=VN00033897&countryCode=US&language=en (accessed 2026-11-16)
- MilliporeSigma / Merck KGaA: Safety Data Sheet – Petroleum ether (Product 32299). https://www.sigmaaldrich.com/US/en/sds/sial/32299 (accessed 2026-11-16)
- Carl Roth GmbH + Co. KG: Safety Data Sheet – Petroleum benzine 40-60 °C (Product T173). https://www.carlroth.com/medias/SDB-T173-EN-EN.pdf (accessed 2026-11-16)
- U.S. Environmental Protection Agency (EPA): 40 CFR Part 261 Identification and Listing of Hazardous Waste. https://www.ecfr.gov/current/title-40/chapter-I/subchapter-I/part-261 (accessed 2026-11-16)
- National Fire Protection Association (NFPA): NFPA 30 Flammable and Combustible Liquids Code (2024 Edition). https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=30 (accessed 2026-11-16)
Data: Safety Data Comparison Across Petroleum Ether Boiling Cuts
Comparative safety data sheet metrics across commercial petroleum ether cuts, compiled from manufacturer SDS disclosures (Fisher Scientific, MilliporeSigma, Carl Roth), NIOSH Pocket Guide (CAS 8032-32-4), and NFPA 30 classification standards.
Period covered: 2024-2026. Coverage: United States and European Union.
| Solvent Grade / Cut | Boiling Range Minimum (°C) | Boiling Range Maximum (°C) | Closed Cup Flash Point (°C) | Autoignition Temperature (°C) | NFPA 30 Flammable Class | Primary GHS Flammability Category | NIOSH REL TWA (mg/m³) |
|---|---|---|---|---|---|---|---|
| Petroleum Ether 30-60 °C (Light Cut) | 30 | 60 | -40 | 280 | Class IA | Flammable Liquid Category 2 | 350 |
| Petroleum Ether 40-60 °C (Standard ACS) | 40 | 60 | -45 | 260 | Class IB | Flammable Liquid Category 2 | 350 |
| Petroleum Ether 60-80 °C (Hexane Fraction) | 60 | 80 | -25 | 260 | Class IB | Flammable Liquid Category 2 | 350 |
| Petroleum Ether 80-100 °C (Heptane Cut) | 80 | 100 | -9 | 250 | Class IB | Flammable Liquid Category 2 | 350 |
| Petroleum Ether 100-120 °C (Ligroin Heavy) | 100 | 120 | 10 | 240 | Class IB | Flammable Liquid Category 2 | 350 |
Sources
- Thermo Fisher Scientific Safety Data Sheet: Petroleum Ether ACS (E139-4) (accessed 2026-11-16)
- Merck KGaA / MilliporeSigma Safety Data Sheet: Petroleum ether (32299) (accessed 2026-11-16)
- Carl Roth GmbH Safety Data Sheet: Petroleum benzine 40-60 °C (T173) (accessed 2026-11-16)
- NIOSH Pocket Guide to Chemical Hazards: VM & P Naphtha (CAS 8032-32-4) (accessed 2026-11-16)
- NFPA 30: Flammable and Combustible Liquids Code (2024 Edition) (accessed 2026-11-16)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.