Written and maintained by CASRAI Editorial Board
Published
On this page
Phoenix WinNonlin is pharmacokinetic (PK) and pharmacodynamic (PD) analysis software sold by Certara. Its best-documented use is non-compartmental analysis (NCA): turning measured drug concentration-time data into exposure and elimination parameters such as Cmax, AUC, half-life and clearance. Published bioequivalence and bioavailability studies name it as the tool that produced those parameters and the confidence intervals around them.
Short answer: what Phoenix WinNonlin is used for
On its own product page, Certara describes Phoenix WinNonlin as “the industry standard for non-compartmental analysis (NCA) and PK/PD modeling” (a vendor description, read 2026-11-19, not a regulatory designation). The page lists four study types it supports: bioequivalence and bioavailability, dose-proportionality and drug interaction, clinical pharmacology and special populations, and toxicokinetics. Independent papers show the same pattern in practice: a 2018 tuberculosis study and a 2026 diclofenac bioequivalence trial both report that their PK parameters came from NCA in Phoenix WinNonlin.
The rest of this page separates three things that searchers often run together: what NCA actually computes, what the Certara Phoenix product family adds around WinNonlin, and what a methods section should record so that another analyst can reproduce the numbers. This page describes software and analysis methods in general terms; it is not medical advice and it gives no prices.
What is Certara Phoenix, and how does WinNonlin fit in?
Certara is the company that publishes the Phoenix software line. Phoenix WinNonlin is one product in that line, and it is the one most often cited in study methods. According to the WinNonlin product page, the related Phoenix products are Phoenix Cloud, Phoenix NLME, PK Submit, Integral (included with Phoenix Hosted), the Phoenix IVIVC Toolkit, Pirana, Trial Simulator, Phoenix TFL Studio and AI PK Reports. The page described version 8.8 as the newest release on 2026-11-19.
That naming matters when you search or cite. “Phoenix” is the family, “WinNonlin” is the NCA and PK/PD analysis product inside it, and “Certara Phoenix” in everyday speech usually means one of the two. A methods section should name the exact product and version used, as the two papers discussed below do (“Phoenix/WinNonlin software v. 6.4” in one, “Phoenix WinNonlin” in the other), rather than writing “Phoenix” alone.
What is Phoenix WinNonlin used for?
The product page gives the vendor’s view: an NCA engine for studies “from early non-clinical research to large clinical trials”, with data import, dataset preparation, calculations and report generation organised as reusable, reproducible workflows. It also states that a validation suite supports compliance with US FDA requirements, and it names the FDA, PMDA, CFDA and MHRA among regulators it says use the software. Treat those as the vendor’s statements about itself. A regulator accepting a submission that was analysed in a given tool is different from a regulation requiring that tool, and no source read for this page says any agency requires WinNonlin.
Bioequivalence and bioavailability analysis
In the 2018 Clinical Pharmacology and Therapeutics study by Browne and colleagues, a randomized crossover PK study in 12 patients with active tuberculosis compared a co-encapsulated formulation with native Rifamate. The authors ran the bioequivalence analysis in what they describe as the FDA-recognized Phoenix WinNonlin software, using the population ratio method within its bioequivalence tool, with 95% confidence intervals around the ratios, and linear mixed-effects modeling reported in the results. The individual parameters were t1/2, CL/F, Cmax, Ctrough and AUC from non-compartmental analysis in Phoenix/WinNonlin version 6.4.
In the 2026 study by Sun and colleagues in Clinical Pharmacology in Drug Development, two bioequivalence trials of a diclofenac sodium sustained-release tablet (one fasting, one fed) used a fully replicated crossover design. Plasma diclofenac was measured by LC-MS/MS, and the PK parameters were calculated by NCA in Phoenix WinNonlin. The authors applied either average bioequivalence or reference-scaled average bioequivalence, depending on the within-subject variability of the reference product, and judged 90% confidence intervals for the geometric least-squares mean ratios of Cmax, AUC0-t and AUC0-inf against acceptance limits.
Other study types the vendor lists
Dose-proportionality and drug interaction studies, clinical pharmacology and special-population studies, and toxicokinetics are the other categories on the product page. No independent paper was read for those categories here, so this page does not describe how any specific study configured them. For the regulatory background of nonclinical exposure studies, see the CASRAI guide to toxicokinetics in nonclinical safety studies.
What NCA computes: the parameters behind the software
NCA computes PK parameters directly from measured concentration-time data and, in the words of MathWorks’ SimBiology documentation, “does not require the assumption of a specific compartmental model.” That is the reason NCA is the default for bioequivalence work: the analyst is not choosing a structural model whose assumptions could be disputed. The table in the data section below sets out each standard NCA parameter, its definition and which of the two papers reports it. The main relationships, as documented by MathWorks for its own NCA implementation (the definitions are general NCA conventions, but this is the source read), are:
- Cmax and Tmax: the maximum observed concentration and the time at which it occurs.
- AUC0-last: the area under the concentration-time curve up to the last measured time point. AUC0-inf adds an extrapolated tail calculated from the terminal rate constant, λz.
- λz: the terminal rate constant, estimated by regressing log concentration against time using the last n points of the terminal phase. In the SimBiology implementation at least three points are required, and the regression with the most points and the maximum adjusted R² is chosen.
- Half-life = ln(2)/λz.
- Clearance = dose/AUC0-inf for single dosing. After oral dosing papers such as Browne et al. report CL/F, apparent clearance, because bioavailability F is not separately known.
Each of those steps contains an analyst decision, and the decisions differ between tools and settings. MathWorks documents a linear trapezoidal default and a linear-up log-down option for the AUC calculation, which uses linear trapezoids while concentrations rise or stay constant and log trapezoids while they decline. It also warns that for drugs with long half-lives the extrapolation to infinity “can lead to approximation errors”. Those documented choices are exactly the settings a WinNonlin user also has to decide and report; the Certara page read for this page does not list its own default settings, so do not assume they match another package.
What software is commonly used for pharmacokinetic analysis?
Two tools appear in the sources read for this page. Phoenix WinNonlin is named in both published studies above and presented by its vendor as an NCA and PK/PD modeling product. SimBiology, MathWorks’ MATLAB-based modeling environment, includes an NCA function, documented on the page cited here; the CASRAI guide to SimBiology for QSP, PK/PD and PBPK covers that tool’s wider scope. This page does not rank the two, and no source read here compares their outputs. If your protocol or sponsor names a tool, follow that; if you choose one, record the product, version and settings so the analysis is reproducible.
Where it matters for labs, clinical pharmacology units and submissions
Three situations make the tool choice and its documentation matter in research practice.
- Bioequivalence and bioavailability trials. The regulatory outcome rests on confidence intervals for Cmax and AUC ratios, so the NCA settings and the statistical model (average, reference-scaled average, population ratio) are part of the result, not just the plumbing. The CASRAI guide to the FDA drug approval process places these studies in the wider path from application to approval.
- Nonclinical toxicokinetics. The vendor lists toxicokinetics as a supported study type. Exposure parameters from animal studies are reported alongside safety findings; see the toxicokinetics guide linked above.
- Protocol and statistical analysis planning. The analysis choices belong in the clinical trial protocol or analysis plan before data are unblinded, consistent with the principles in ICH E9.
What a methods section should record
This checklist is an editorial synthesis of what the two papers above state and what the MathWorks documentation shows is configurable; it is not a regulatory template.
- The exact product and version (for example, “Phoenix/WinNonlin software v. 6.4, Certara” as written by Browne et al.).
- That the parameters were derived by non-compartmental analysis, and which parameters (Cmax, AUC0-t, AUC0-inf, t1/2, CL/F and so on).
- The AUC rule (linear, or linear-up log-down) and how λz points were chosen, including the minimum number of terminal points.
- For bioequivalence, the model: average bioequivalence, reference-scaled average bioequivalence, or a population ratio approach, with the confidence-interval level (Browne et al. used 95% intervals around ratios; Sun et al. used 90% intervals for geometric least-squares mean ratios).
- The bioanalytical method that produced the concentrations (Sun et al. state LC-MS/MS).
Common misunderstandings
“Industry standard” is a vendor description
The phrase comes from Certara’s own page. It is a claim about market position, not a regulation, and none of the sources read says a regulator mandates this software.
WinNonlin, Phoenix and Certara Phoenix are not three products
They are the product, the family and an informal way of referring to either. Cite the product and version.
NCA is not the same as compartmental or population modeling
NCA needs no structural model. The WinNonlin product page does not describe compartmental modeling, and population modeling sits with other Phoenix products such as the NLME product it lists. Do not describe an NCA result as a model fit.
Different tools can give different numbers with different settings
AUC rules, λz point selection and handling of values below the limit of quantification differ between implementations; MathWorks, for example, truncates values below the lower limit of quantification to zero. Reproducing a published result means matching these settings, not just the software name.
Price and download questions
People also search for Phoenix WinNonlin price, tutorial and download. The product page read for this page gives no price, so this page gives none; licensing questions go to the vendor. Software obtained from unofficial sources is not a basis for a validated regulatory or publication analysis.
Frequently asked questions
What is Phoenix WinNonlin used for?
It is used for pharmacokinetic and pharmacodynamic analysis, above all non-compartmental analysis of concentration-time data. Certara lists bioequivalence and bioavailability, dose-proportionality and drug interaction, clinical pharmacology and special populations, and toxicokinetic studies; published trials use it to derive Cmax, AUC and related parameters and bioequivalence confidence intervals.
What software is commonly used for pharmacokinetic analysis?
The two published studies read for this page both used Phoenix WinNonlin, and MathWorks documents NCA inside SimBiology. No source read here ranks tools or gives usage shares, so choose the tool your protocol, sponsor or institution specifies and document its version and settings.
What is Phoenix software used for?
“Phoenix” is Certara’s software family. Per the WinNonlin product page it includes WinNonlin for NCA and PK/PD analysis, plus Phoenix Cloud, NLME, PK Submit, Integral, IVIVC Toolkit, Pirana, Trial Simulator, TFL Studio and AI PK Reports. Which product you need depends on the analysis; the page does not describe all of them in detail.
What is Certara Phoenix?
Certara Phoenix is the name people use for the Certara-published Phoenix product line, most often meaning Phoenix WinNonlin. Certara is the vendor; the papers in the sources section cite the software as “Phoenix/WinNonlin … Certara”.
Sources
- Certara: Phoenix WinNonlin product page, checked 2026-11-19
- Browne SH et al., Clinical Pharmacology and Therapeutics 2018;103(3):502-510 (PMC5836848), checked 2026-11-19
- Certara publication listing: Sun B et al., Clinical Pharmacology in Drug Development, 1 January 2026, doi:10.1002/cpdd.70019, checked 2026-11-19
- MathWorks: Non-compartmental analysis (SimBiology documentation), checked 2026-11-19
Data: Non-compartmental PK parameters: definition and where two published Phoenix WinNonlin studies report them
Cross-walk compiled for this page. Definitions of standard NCA parameters come from MathWorks' SimBiology NCA documentation (read 2026-11-19); the last two columns record whether the Browne et al. 2018 tuberculosis study and the Sun et al. 2026 diclofenac bioequivalence study state that parameter in the abstract or methods text read. Yes means stated, No means not stated in the text read.
| Parameter | Definition | Reported by Browne et al. 2018 | Reported by Sun et al. 2026 |
|---|---|---|---|
| Cmax | Maximum observed concentration | Yes | Yes |
| Tmax | Time at which the maximum observed concentration occurs | No | No |
| AUC0-t (AUC0-last) | Area under the concentration-time curve up to the last measured time point | Yes (as AUC) | Yes (AUC0-t) |
| AUC0-inf | AUC0-last plus an extrapolated tail from the terminal rate constant | No | Yes |
| Terminal rate constant (lambda z) | Estimated by regressing log concentration on time over the last n terminal points; at least three points in SimBiology | No | No |
| Half-life (t1/2) | ln(2) divided by lambda z | Yes | No |
| Clearance (CL, or CL/F after oral dosing) | Dose divided by AUC0-inf for single dosing; CL/F is apparent clearance | Yes (CL/F) | No |
| Ctrough | Concentration at the end of a dosing interval; not defined in the MathWorks page read | Yes | No |
Sources
- MathWorks: Non-compartmental analysis (SimBiology) (accessed 2026-11-19)
- Browne SH et al., Clin Pharmacol Ther 2018 (PMC5836848) (accessed 2026-11-19)
- Sun B et al., Clin Pharmacol Drug Dev 2026 (Certara publication listing) (accessed 2026-11-19)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.