Pinch Gauge: Capacities, Pinch Types and How to Read the Dial

Pinch gauge capacity chart in lb and kg, the three pinch tests, and how to zero and read the dial, from manufacturer instructions.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

General product information only, not medical advice. Interpreting any pinch-strength reading belongs to a qualified clinician.

A pinch gauge is a small handheld force gauge that measures how hard a person can squeeze between thumb and fingers. Its capacity (2 to 60 lb on the mechanical models below) sets what it can measure, and the dial is read in pounds or kilograms. This page is a lookup for those capacities and for reading the dial; for grip-style devices see hand dynamometers.

Pinch gauge capacities at a glance

Gauge type Capacity (lb) Capacity (kg)
Mechanical, gold dial 2 0.9
Mechanical, silver dial 10 4.5
Mechanical, blue dial 30 13.6
Mechanical, red dial 60 27
Hydraulic (standard or Hi-Res head) 50 23
Electronic, LCD 50 23

Values come from the Baseline (Fabrication Enterprises) pinch gauge instructions and the Performance Health/Baseline product brochure. The colours are that maker’s product colours, not a standard: no standard defines pinch gauge colour or size codes, so always check your product’s labelling for its capacity and units.

How to read a pinch gauge

Read the pointer against the scale, in pounds or kilograms as the dial shows; the maker’s gauges carry both. The maximum-reading indicator stays at the highest value reached until it is reset, so the number you see is the peak of the squeeze, not the live force. The maker’s instructions say the gauge must be zeroed before each pinch test, and the red maximum pointer reset each time.

Tip, key and palmar pinch: which test is which

  • Tip pinch (thumb-index pulp pinch): thumb tip to index fingertip.
  • Key pinch (lateral pinch): thumb pad against the side of the middle segment of the index finger.
  • Palmar pinch (chuck pinch): thumb pad against the pads of the index and middle fingers.

The maker’s sheet names these three tests for its gauges. Results from one pinch type should not be compared with another.

Choosing a capacity

Each model’s capacity and units are printed on its labelling, and the maker lists its 2, 10, 30 and 60 lb mechanical models and its 50 lb hydraulic and electronic models as separate products. Check the labelling and the maker’s instructions for the model you have.

Equivalence notes: pounds, kilograms, hydraulic and mechanical

  • Pounds to kilograms: 1 lb = 0.4536 kg, so 30 lb is about 13.6 kg and 50 lb about 23 kg.
  • Mechanical, hydraulic and electronic: the maker lists all three; the Jamar hydraulic model and the LCD electronic model share a 50 lb (23 kg) capacity. A Hi-Res hydraulic head is a different head from the standard one, so record which gauge and head produced a reading rather than mixing them.
  • 5-position gauge: the Baseline 5-position hydraulic gauge has an adjustable paddle for different hand sizes; the maker states its pinch width without the paddle is the same as the standard gauge.

Common mix-ups

  • Position on the gauge: the maker notes the reading is slightly higher when force is applied nearer the tip and slightly lower nearer the rear, so keep the placement consistent.
  • Forgetting to zero or reset: the held maximum pointer carries over to the next test unless reset.
  • Pounds vs kilograms: read the scale you intend; both appear on the dial.
  • Pinch gauge vs hand dynamometer: the US FDA describes a nonpowered dynamometer as a mechanical device intended for medical purposes to measure the pinch and grip muscle strength of a patient’s hand (21 CFR 888.1250, checked 2026-10-31). Grip devices are covered in the hand dynamometer guide, and finger-strengthening tools in the hand exerciser guide.
  • Pinch gauge vs goniometer: a pinch gauge measures force; joint angle is measured with a goniometer.

Frequently asked questions

What does a pinch gauge measure?

Pinch force between thumb and fingers, in pounds or kilograms, for tip, key and palmar pinch.

What capacities do pinch gauges come in?

The maker’s mechanical gauges are 2, 10, 30 and 60 lb; its hydraulic and electronic gauges are 50 lb.

Do I need to zero a pinch gauge?

The maker says the gauge must be zeroed before each pinch test and the maximum pointer reset.

Is a pinch gauge a regulated device?

Nonpowered dynamometers that measure pinch and grip strength are identified in 21 CFR 888.1250. See also the Medical Device Amendments of 1976. Related equipment is listed under diagnostic, monitoring and imaging supplies.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Pinch Gauge: Capacities, Pinch Types and How to Read the Dial

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →