Sartorius Pipettes: Tacta, Proline Plus and Picus 2 Compared

Sartorius pipette lines compared: Tacta, Proline Plus and Picus 2 ranges, autoclaving, filter care and ISO 8655 calibration.

Written and maintained by CASRAI Editorial Board

Published

On this page

Sartorius pipettes are laboratory liquid-handling instruments made by Sartorius, sold in three main families: the mechanical Tacta and Proline Plus pipettes, and the electronic Picus 2 (which replaces the phased-out Picus). Tacta and Proline Plus are listed with single-channel ranges of 0.1 µL to 10,000 µL and multichannel ranges of 0.5 µL to 300 µL; Picus 2 is listed at 0.2 µL to 10,000 µL single-channel and 0.2 µL to 1,200 µL for its multichannel models. The sections below set the three families side by side, then cover how they are built, what Sartorius says about autoclaving and maintenance, and how pipette performance is judged under ISO 8655.

A sartorius pipette, or pipette sartorius in search shorthand, is therefore not one product but a product range. Which specification applies depends on the family, so the first step in reading any range or feature claim is to identify the line (Tacta, Proline Plus or Picus 2) and whether the model is single-channel, multichannel or fixed-volume. Researchers, lab technicians and lab managers who dispense liquids by the microlitre are the people who use these instruments; the manufacturer’s own application pages name drug discovery, sample preparation and cell biology as typical work.

What a Sartorius pipette is

The word pipette here means a micropipette-class, hand-held, air-displacement liquid handler used to aspirate and dispense measured volumes into a tip. If you need the general concept first, see what is a pipette and what is a micropipette; this page covers one manufacturer’s lines. Sartorius describes its range as built around ergonomics, connectivity and reliability, and groups its pipette portfolio into electronic pipettes, mechanical pipettes, multichannel pipettes, pipette tips, bottle-top dispensers, accessories and pipette controllers for serological pipettes.

How Sartorius pipettes are built

The mechanical lines share a set of design features that the manufacturer lists on its product pages. These are statements from Sartorius, not independent test results.

Mechanical pipettes: Tacta and Proline Plus

Both mechanical lines use click-stop volume adjustment. Proline Plus has a large forward-facing display, does not allow the dial to be turned outside the marked volume range, and is described as needing low pipetting force, with ergonomic finger support. Tacta adds an Optilock volume lock that can be operated with one or two hands, a four-digit display readable at an angle, and Optiject levered tip ejection.

For multichannel models, Sartorius describes Optiload spring-loaded tip cones, which are meant to load and eject tips with minimal force and to seat tips evenly across channels. On models above 10 µL, the tip cone holds a replaceable Safe-Cone filter. Both lines have an ejection collar that can be rotated to lengthen or shorten tip ejection for extended tips.

Electronic pipettes: Picus 2

Picus 2 is the connected, motor-driven line. Sartorius lists Bluetooth connectivity, a large digital display, password protection, programmable calibration reminders, electronic tip ejection and a Sartorius Pipetting app for protocols and software updates. The preceding Picus page describes a battery that lasts a full working day in many cases, charging through a USB adapter, a single stand or a four-pipette carousel, saved pipetting programs, a plate tracker and mixing through an ADV softkey. Of those, the saved programs, plate tracker and mixing are documented on the Picus page, which now states that Picus has been phased out and recommends Picus 2 as the replacement.

Types and variants

The table compares the three current families and the retired Picus using only what the manufacturer pages state. A blank ‘not stated’ means the page read does not say, which is different from ‘no’.

Line Drive Features stated by Sartorius Autoclaving
Tacta Mechanical Optilock volume lock, Optiload tip cones, Optiject levered ejection, calibration adjustment with key and scale on the back, adjustable ejection collar Steam-sterilized or autoclaved as-is, without disassembly
Proline Plus Mechanical Click-stop adjustment, forward-facing display, dial lock outside range, fixed-volume models, adjustment tool included Described as fully autoclavable; remove the Safe-Cone filter first
Picus 2 Electronic Bluetooth, password protection, calibration reminders, electronic tip ejection, Pipetting app Not stated
Picus (phased out) Electronic Saved programs, plate tracker, mixing, USB, stand or carousel charging Not stated

Single-channel and multichannel pipettes are separate variants within each family. Sartorius’s overview describes multichannel pipettes in 8- or 12-channel formats, available as mechanical or electronic models. For the general trade-offs between the two formats, see micropipette types: single versus multichannel.

Volume ranges and specifications

The data table below lists the stated volume ranges for each family and format. All values are the nominal ranges printed on the Sartorius product pages and one launch press release; no accuracy or precision limits are published on those pages, so none are given here. Proline Plus also lists fixed-volume single-channel models from 5 µL to 10,000 µL.

A single family spans the whole range only across several models, since a single pipette covers only part of it. The 0.1 µL to 10,000 µL figure is the family’s overall coverage, not what one pipette dispenses. Always read the range printed on the particular model before choosing a tip or protocol.

Tips, filters and accessories that go with them

Sartorius sells Optifit tips and Safetyspace filter tips and says they are designed to match its pipettes. A pipette and its tips work as a system, so tips matter to the result as well as the pipette. For selecting among tip types see the pipette tip selection guide, and for the difference between filter tips and ordinary tips see what are filtered pipette tips. The Safe-Cone filter in the pipette’s own tip cone is a separate component from a filter tip: it sits in the pipette, and Sartorius says to replace it regularly and always if liquid contacts it.

Other items in the Sartorius family include bottle-top dispensers and burettes, and pipette controllers used to control aspiration and dispensing with serological pipettes. These are different instrument classes, not variants of the micropipettes above.

How to choose between the families

The manufacturer pages support a few concrete differences, and no more than these. They are not a ranking.

  • Autoclaving as a requirement. Tacta and Proline Plus are described as autoclavable; the Picus 2 pages read do not state it. If a protocol requires steam sterilization of the pipette body, the stated position of the family matters.
  • Fixed volume. Fixed-volume single-channel models are listed under Proline Plus, from 5 µL to 10,000 µL.
  • Electronic features. Saved pipetting programs, a plate tracker, calibration reminders and app-based protocols are listed for the Picus family and Picus 2, not for the mechanical lines.
  • Lower range. Picus 2 single-channel is listed from 0.2 µL, against 0.1 µL for the mechanical single-channel lines. A requirement in this region should be checked against the specific model.

Safe use and maintenance basics

Maintenance guidance below comes from the Sartorius pages and applies to the mechanical lines.

  • Do not turn the volume dial outside the marked range. Proline Plus is built to stop this.
  • Remove the Safe-Cone filter before autoclaving, as Sartorius’s FAQ states for Proline Plus, and replace the filter regularly and always after liquid contact.
  • Tacta and Proline Plus have three parts to disassemble for cleaning, with no tools required; an adjustment tool is included with Proline Plus.
  • For adjustment, Sartorius says to use a balance to determine the systematic error for a given liquid and then apply the correction table in the manual.
  • Sartorius also offers calibration, maintenance and repair services, and training through its Pipetting Academy.

Wider technique, such as how to hold, aspirate and dispense, is covered in pipetting technique and best practices.

Calibration and ISO 8655

Pipette performance is judged against ISO 8655-2:2022, the standard for piston-operated pipettes. Its total-system principle treats the pipette and the specific tip as one system, so the permitted errors apply to the combination, and using third-party tips calls for validation against the standard’s tolerances. The Sartorius mechanical-pipette pages read for this page do not state ISO 8655 limits, so this page does not give a conformity claim for any model. Readers who need limits should consult the standard’s tables and the model’s own documentation.

Sartorius lists a Cubis II MPS116S balance for pipette calibration, described as covering 95% of single-channel pipette volumes from 2 µL to 5 mL. For when and how to calibrate in general, see pipette calibration: how and when.

Common mistakes

  • Quoting a range without naming the family. Different pages state different ranges for Tacta, Proline Plus and Picus 2.
  • Autoclaving with the Safe-Cone filter fitted.
  • Leaving a filter in service after liquid has reached it.
  • Turning the dial past its stop on a pipette that lacks a dial lock.
  • Treating a phased-out model’s page as current: Picus has been replaced by Picus 2.

Sources

Data: Stated volume ranges of Sartorius Tacta, Proline Plus and Picus 2 pipettes

Nominal volume ranges by pipette family and channel format, compiled from Sartorius product pages and a Sartorius press release for Picus 2; values are manufacturer-stated ranges, not tested performance.

Period covered: 2023/2026.

Stated volume ranges of Sartorius Tacta, Proline Plus and Picus 2 pipettes
Family and formatMinimum volume (µL)Maximum volume (µL)Drive
Tacta single-channel0.110000Mechanical
Tacta multichannel0.5300Mechanical
Proline Plus single-channel0.110000Mechanical
Proline Plus multichannel0.5300Mechanical
Proline Plus fixed-volume single-channel510000Mechanical
Picus 2 single-channel0.210000Electronic
Picus 2 multichannel (2|2 models)0.21200Electronic

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Sartorius Pipettes: Tacta, Proline Plus and Picus 2 Compared

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →