Written and maintained by CASRAI Editorial Board
Published
On this page
Polynomial regression in Excel is a statistical method used to fit a non-linear curvilinear relationship between a continuous independent predictor variable (X) and a dependent response variable (Y) by modeling Y as an nth-degree polynomial equation. Researchers implement polynomial regression in Microsoft Excel using two primary techniques: the dynamic array function LINEST with exponential powers to obtain exact least-squares coefficients with comprehensive standard errors, and XY Scatter chart polynomial trendlines for visual curve fitting and rapid prediction.
What it is used for in research
In empirical scientific and engineering research, many physical, biological, and economic phenomena do not adhere to strictly linear trajectories. When the rate of change in an outcome depends on the level of the predictor itself, standard simple linear regression produces biased predictions, correlated residuals, and systematically inaccurate inferences. In these settings, researchers apply polynomial regression to capture curvature, inflection points, and local maxima or minima while remaining within the mathematically tractable framework of Ordinary Least Squares (OLS) estimation.
Because the polynomial model expresses the dependent variable as a linear combination of power-transformed predictors—such as quadratic (X2), cubic (X3), or higher-order terms—it remains strictly linear in its parameters (β0, β1, β2, …, βk). Consequently, all classical Gauss-Markov assumptions, matrix inversion procedures, and hypothesis tests developed for standard linear regression directly apply. Researchers routinely use polynomial regression in Excel for several key empirical tasks:
- Dose-Response and Biochemical Titration Curves: Modeling enzymatic reaction rates, substrate saturation, and pharmacological response gradients where initial acceleration transitions into diminishing returns or substrate inhibition.
- Physical Calibration and Sensor Calibration: Fitting calibration curves for instruments such as thermocouples, spectrophotometers, pressure transducers, and chromatographic detectors where voltage or absorbance deviates quadratically or cubically across operational extremes.
- Agricultural and Environmental Yield Optimization: Identifying diminishing marginal returns, crop yield response to fertilizer application rates, and environmental pollutant dispersion profiles.
- Economic and Production Cost Modeling: Estimating short-run marginal cost and total cost curves exhibiting U-shaped or inverted U-shaped profiles reflecting classical economies and diseconomies of scale.
- Empirical Benchmark Tracking: Evaluating non-linear developmental metrics and behavioral trajectories against continuous operational timelines.
When selecting independent and dependent variables, researchers must ensure that the hypothesized polynomial degree reflects either an underlying physical mechanism or an exploratory empirical approximation within a bounded operational range. In particular, researchers must avoid omitted variable bias by testing whether the omission of higher-order polynomial terms systematically distorts the estimated coefficients of lower-order parameters.
Despite its mathematical accessibility, polynomial regression introduces two substantial methodological risks in applied research: structural multicollinearity and high-order boundary instability. Because powers of the same predictor (such as X, X2, and X3) are naturally correlated—especially when X values are strictly positive and far from zero—uncentered polynomial regression models often generate near-singular design matrices. This condition inflates standard errors, distorts individual t-statistics, and renders coefficient estimates sensitive to minor data perturbations. Furthermore, fitting high-degree polynomials (orders 4 through 6) frequently triggers Runge’s phenomenon, wherein the polynomial oscillates erratically near the boundaries of the data interval. Researchers must therefore prioritize low-degree formulations (typically quadratic or cubic) and employ parameter centering to maintain stable matrix inversion.
Install or access
Performing polynomial regression in Microsoft Excel relies entirely on built-in native functions and the standard Analysis ToolPak add-in. No third-party commercial software, paid plugins, or external subscriptions are required. Access procedures depend on whether you utilize dynamic worksheet array functions or the full graphical user interface of the Analysis ToolPak.
Native Worksheet Functions in Microsoft 365 and Excel
The core computational engine for polynomial modeling in Excel is the LINEST function, supported across Microsoft 365, Excel 2024, Excel 2021, Excel 2019, Excel 2016, and Excel for the Web. In modern dynamic array versions of Excel (Microsoft 365 and Excel 2021 or later), entering a formula that returns a matrix automatically spills the entire coefficient and statistics table into neighboring cells without manual array allocation. In legacy versions (Excel 2019 and earlier), users must pre-select the exact destination range (5 rows high by k+1 columns wide) and commit the formula using the legacy array shortcut Ctrl+Shift+Enter (CSE).
Activating the Analysis ToolPak Add-in
While basic curve equations can be plotted directly on XY Scatter charts, obtaining complete regression tables containing ANOVA sums of squares, residual outputs, and 95% confidence intervals requires the Analysis ToolPak. The Analysis ToolPak is an official add-in included with all desktop installations of Microsoft Excel for Windows and macOS. To enable it, follow the official vendor configuration steps:
- Open Excel Options: Launch Microsoft Excel, click the File tab in the upper-left corner of the ribbon, and select Options at the bottom of the navigation pane (on macOS, click the Tools menu on the system menu bar and select Excel Add-ins).
- Navigate to Add-ins Management: In the Excel Options dialog box, select the Add-ins category from the left-hand menu.
- Select Excel Add-ins: At the bottom of the Add-ins panel, locate the Manage drop-down menu, ensure Excel Add-ins is selected, and click the Go… button.
- Enable the ToolPak: In the Add-ins pop-up dialog box, check the box adjacent to Analysis ToolPak. Do not select “Analysis ToolPak – VBA” unless you intend to call analysis functions from visual basic macros.
- Confirm and Verify: Click OK. Excel integrates the tools into the application ribbon. To verify activation, navigate to the Data tab and confirm that a new Analysis group containing the Data Analysis button is visible on the far right.
Step-by-step task
Fitting a rigorous polynomial regression model in Excel involves data preparation, algebraic transformation, execution through either worksheet functions or the Data Analysis dialogue, and graphical verification. The following numbered workflow details each step using an empirical research example.
Step 1: Structure Data and Center the Independent Predictor
Begin by organizing your continuous independent and dependent variables in adjacent worksheet columns. To prevent extreme structural multicollinearity between power terms, center the predictor variable by subtracting its sample mean prior to calculating quadratic or cubic powers.
- Place your raw independent variable values (X) in column A (cells
A2:A21) and your raw dependent outcome values (Y) in column B (cellsB2:B21), placing descriptive headers in row 1. - In cell
C2, compute the centered predictor (xc = X – X̄) by entering the formula:
=A2 - AVERAGE(A$2:A$21)
Copy this formula down through cellC21. - In cell
D2, compute the quadratic term (xc2) by entering:
=C2^2
Copy down through cellD21. - In cell
E2, compute the cubic term (xc3) by entering:
=C2^3
Copy down through cellE21.
By centering the predictor around zero, the correlation between xc and xc2 drops dramatically, eliminating catastrophic numerical roundoff errors during matrix inversion.
Step 2: Fit the Polynomial Model Using LINEST
To fit a polynomial regression in Excel directly in worksheet cells without creating helper power columns, use the dynamic array constant syntax in LINEST. This method calculates exact IEEE 754 double-precision coefficients.
- Select an empty cell where you want the upper-left corner of the regression output to appear (for example, cell
G2). - For a second-order (quadratic) polynomial model, enter the following dynamic array formula:
=LINEST(B2:B21, A2:A21^{1,2}, TRUE, TRUE) - For a third-order (cubic) polynomial model, enter:
=LINEST(B2:B21, A2:A21^{1,2,3}, TRUE, TRUE) - In modern Excel (Microsoft 365 / Excel 2021+), press Enter. The formula automatically spills into a block 5 rows deep and 3 columns wide for quadratic (or 4 columns wide for cubic). In legacy Excel (Excel 2019 or older), highlight a range of 5 rows by 3 columns (e.g.,
G2:I6), type the formula, and press Ctrl+Shift+Enter.
If you prefer to extract individual parameter estimates into specific standalone summary cells without creating spilled tables, wrap the LINEST call inside the INDEX function:
- Quadratic coefficient (m2):
=INDEX(LINEST(B2:B21, A2:A21^{1,2}, TRUE, FALSE), 1) - Linear coefficient (m1):
=INDEX(LINEST(B2:B21, A2:A21^{1,2}, TRUE, FALSE), 2) - Intercept constant (b):
=INDEX(LINEST(B2:B21, A2:A21^{1,2}, TRUE, FALSE), 3) - Coefficient of determination (R2):
=INDEX(LINEST(B2:B21, A2:A21^{1,2}, TRUE, TRUE), 3, 1) - Regression standard error (sey):
=INDEX(LINEST(B2:B21, A2:A21^{1,2}, TRUE, TRUE), 3, 2)
For research projects comparing polynomial models with multiple covariate controls, refer to our comprehensive companion guide on multiple regression in Excel.
Step 3: Construct an XY Scatter Plot with a Polynomial Trendline
To inspect the fitted curve against empirical data points, construct an XY Scatter chart and overlay an official Excel polynomial trendline:
- Highlight your raw data range containing X and Y (cells
A1:B21). - Navigate to the Insert tab on the ribbon. In the Charts group, click Insert Scatter (X, Y) or Bubble Chart and choose Scatter (markers only, without connecting lines).
- Click on any data marker in the chart to select the series. Right-click the series and choose Add Trendline… from the context menu (or click the green + Chart Elements icon at the top right of the chart, hover over Trendline, click the arrow, and select More Options…).
- In the Format Trendline task pane on the right, under Trendline Options, select the radio button for Polynomial.
- In the Order box, specify your desired degree between
2and6(default is2for quadratic). - Scroll down in the task pane and check both Display Equation on chart and Display R-squared value on chart.
- Format Equation Precision: Click on the equation text box on the chart to select it. In the Format Trendline Label pane, select Label Options (the bar chart icon), expand the Number category, change the Category from “General” to Number or Scientific, and increase Decimal places to at least
10. This step prevents severe rounding distortion when evaluating predictions.
Step 4: Execute Full Regression Analysis via the ToolPak
When formal hypothesis testing, residual diagnostic plots, and confidence bounds are required for publication, run the regression tool from the Analysis ToolPak:
- Click the Data tab on the ribbon and select Data Analysis in the Analysis group.
- In the Data Analysis dialog box, scroll down, select Regression, and click OK.
- In the Input Y Range field, enter or select the dependent variable range, including the header (e.g.,
$B$1:$B$21). - In the Input X Range field, select the contiguous columns containing your centered linear and power terms (e.g.,
$C$1:$E$21for a cubic model, encompassing xc, xc2, and xc3). Note that the ToolPak requires all predictor columns to be contiguous. - Check the Labels box to confirm the first row contains column headers.
- Check Confidence Level and leave the default at
95%(or adjust as required by your statistical protocol). - Under Output options, select Output Range and designate a blank worksheet area (e.g.,
$G$10), or select New Worksheet Ply. - Under Residuals, check Residuals, Standardized Residuals, Residual Plots, and Line Fit Plots.
- Click OK to execute the estimation.
Output and how to read it
Executing polynomial regression in Excel generates two distinct statistical outputs: the compact 5-row array returned by LINEST and the comprehensive summary tables produced by the Analysis ToolPak. Understanding how each parameter is structured is essential for accurate scientific reporting.
Reading the LINEST Dynamic Array Grid
The array returned by LINEST(known_y's, known_x's, const, TRUE) follows a rigid mathematical structure. For a polynomial of degree k (e.g., k=2 for quadratic, k=3 for cubic), the output matrix spans 5 rows and k+1 columns:
| Row Index | Column 1 | Column 2 | … | Column k | Column k+1 |
|---|---|---|---|---|---|
| Row 1: Coefficients | mk (coefficient of Xk) | mk-1 (coefficient of Xk-1) | … | m1 (coefficient of X) | b (intercept constant) |
| Row 2: Standard Errors | sek (std. error of mk) | sek-1 | … | se1 | seb (std. error of b) |
| Row 3: Fit Metrics | R2 (coefficient of determination) | sey (std. error of y estimate) | … | #N/A | #N/A |
| Row 4: Model Utility | F (observed F-statistic) | df (degrees of freedom: n – k – 1) | … | #N/A | #N/A |
| Row 5: Sums of Squares | SSreg (regression sum of squares) | SSresid (residual sum of squares) | … | #N/A | #N/A |
A critical point of syntax: LINEST returns coefficients in reverse order of powers. The highest-order term (mk) occupies the leftmost column (Column 1), while the constant intercept (b) occupies the rightmost column (Column k+1). Reversing this ordering when writing predictive formulas is a frequent source of calculation error.
Interpreting the ToolPak Summary Output and ANOVA Table
The Data Analysis ToolPak organizes its results into three distinct sections: Regression Statistics, ANOVA (Analysis of Variance), and Parameter Coefficients.
- R Square and Adjusted R Square: R Square represents the proportion of total variance in the dependent variable explained by the polynomial curve. However, adding higher polynomial degrees automatically increases raw R Square even if the new term captures purely random noise. Researchers must examine Adjusted R Square, which penalizes the metric for each added parameter:
Adjusted R^2 = 1 - [(1 - R^2) * (n - 1) / (n - k - 1)]
If adding a cubic term increases raw R Square from 0.880 to 0.882 but decreases Adjusted R Square from 0.865 to 0.859, the cubic term represents overparameterization and should be omitted. - Standard Error: This metric represents the standard error of the regression (s or sey), quantifying the average dispersion of observed data points around the fitted polynomial curve in the original units of Y.
- ANOVA F-Test and Significance F: The ANOVA table partitions total sum of squares (SS Total) into Regression (SS Regression) and Error (SS Residual). The overall model F-statistic evaluates whether the combined polynomial terms explain significantly more variance than a null intercept-only model. If Significance F (the p-value) is below your chosen alpha threshold (such as p ≤ 0.05), the overall polynomial model is statistically significant.
- Coefficients, t-Statistics, and P-Values: Each row in the coefficients block corresponds to a predictor term (Intercept, X, X2, X3). The P-value column tests the null hypothesis that an individual coefficient equals zero given all other terms in the model. In a sequential polynomial modeling strategy, if the highest-order coefficient (e.g., X3) exhibits a p-value greater than 0.05, it fails the significance test and the model should be simplified to a lower degree.
Evaluating Residual Diagnostic Plots
A high R2 alone does not prove model validity. Researchers must inspect the residual plot generated by the ToolPak (residuals plotted against fitted Y or predictor X). If the residuals display a systematic parabolic or sinusoidal pattern rather than a random horizontal band centered around zero, the polynomial degree remains inadequate, or the true underlying relationship is non-polynomial (e.g., exponential or logistic).
Troubleshooting
When fitting polynomial regression models in Excel, researchers frequently encounter specific formula errors, numerical discrepancies, and graphical failures. The following diagnostics address the most common failure modes.
1. #VALUE! Error Returned by LINEST
The #VALUE! error occurs when Excel cannot parse the input ranges or array constants. Verify the following causes:
- Unequal Range Dimensions: The range of known_y’s and known_x’s must contain identical numbers of rows. A mismatch such as
LINEST(B2:B21, A2:A20^{1,2})immediately throws#VALUE!. - Non-Numeric Text in Data Cells: Ensure no text strings, spaces, or formula errors reside in the data cells. Check that column headers were not accidentally included inside the
LINESTcell range. - Regional Separator Mismatch: In standard US/UK Excel, array constants use commas to separate horizontal elements:
^{1,2,3}. In European and Latin American Excel configurations where the comma serves as the decimal separator, array elements must be separated by backslashes (^{1}) or semicolons.
2. Severe Prediction Errors from Chart Trendline Equations
Researchers often copy the equation displayed on an Excel chart (for example, y = 0.0003x^2 - 0.045x + 12.8) into a calculation cell and find that predicted values deviate wildly from actual chart points. This occurs because Excel’s default chart trendline label displays coefficients rounded to only 2 to 4 significant digits. When X is squared or cubed, truncating a small coefficient (e.g., 0.0003289 rounded to 0.0003) introduces massive compounded calculation errors. Always resolve this by formatting the trendline label to 12 decimal places, or use LINEST directly to compute predictions with 15 digits of IEEE double precision.
3. Collinearity and #NUM! Errors in High-Order Polynomials
Attempting to fit 5th- or 6th-order polynomials to uncentered data frequently causes #NUM! errors or produces coefficient values that reverse signs unexpectedly. This is caused by severe numerical ill-conditioning in the Vandermonde matrix. If X ranges between 100 and 110, X5 ranges between 10,000,000,000 and 16,105,100,000, creating collinearity correlations exceeding 0.99999 between predictors. To eliminate this issue, mean-center your independent variable (X – X̄) or scale X to the interval [-1, 1] prior to calculating powers.
4. Trendline Polynomial Option Is Greyed Out
If the Polynomial radio button in the Format Trendline pane is disabled or greyed out, your chart was constructed as a Line Chart rather than an XY (Scatter) Chart. In a standard Excel Line Chart, the horizontal axis is treated as categorical text labels (1, 2, 3, …), which precludes mathematical polynomial fitting. To resolve this, right-click the chart, choose Change Chart Type, select X Y (Scatter), and click OK.
5. Analysis ToolPak Error: “X Range Must Be a Contiguous Block”
The Regression tool in the Analysis ToolPak does not accept multi-range selections (e.g., holding Ctrl to select column A and column D). All independent variables (X, X2, X3) must reside in physically adjacent columns on the worksheet. Arrange your power columns contiguously prior to launching the Data Analysis dialog.
Free alternatives
While Microsoft Excel provides an accessible environment for basic curve fitting, specialized open-source statistical platforms offer superior numerical precision, automated model selection algorithms, and native orthogonal polynomial support. The data table below compares the functional capabilities, limits, and computational engines of leading free alternatives alongside Microsoft Excel.
| Software Platform | Cost / License | Primary Polynomial Command | Max Native Chart Degree | Orthogonal Polynomials | Key Research Advantage |
|---|---|---|---|---|---|
| GNU PSPP | Free (GNU GPL v3+) | REGRESSION /VARIABLES=... /DEPENDENT=... |
Manual syntax (unlimited) | Manual specification | Free open-source SPSS drop-in replacement with exact ANOVA and collinearity diagnostics. |
| R (stats package) | Free (GNU GPL v2/v3) | lm(y ~ poly(x, degree, raw=FALSE)) |
Unlimited (practical limit ~25) | Built-in native support | Automated orthogonal polynomial decomposition preventing multicollinearity; AIC/BIC model comparison. |
| Python (NumPy / SciPy) | Free (BSD / Open Source) | numpy.polynomial.Polynomial.fit(x, y, deg) |
Unlimited (practical limit ~50) | Built-in Chebyshev, Legendre, Hermite | Modern Polynomial.fit automatically shifts and scales domain to [-1, 1] for optimal conditioning. |
| LibreOffice Calc | Free (LGPL v3+) | LINEST(Y, X^{1,2}, ...) |
Degree 3 in chart trendline | Manual formula | Free cross-platform spreadsheet supporting standard OpenDocument Spreadsheet (ODS) workflows. |
| Julia (GLM / Polynomials) | Free (MIT License) | fit(Polynomial, x, y, deg) |
Unlimited | Built-in via orthogonal packages | High-performance LLVM-compiled numerical execution suitable for massive scientific datasets. |
For scientific publications requiring high-order fitting or rigorous model selection, R and Python provide substantial methodological advantages over Excel. In R, calling poly(x, degree=2, raw=FALSE) generates orthogonal polynomial basis functions, ensuring that the quadratic term is completely uncorrelated with the linear term. This allows researchers to test the independent contribution of each power without variance inflation. In Python, the numpy.polynomial.Polynomial.fit class automatically maps the data domain to [-1, 1], guaranteeing numerical stability without manual centering calculations.
Frequently asked questions
How do you do polynomial regression in Excel without the Analysis ToolPak?
You can perform polynomial regression without the Analysis ToolPak by entering the dynamic array function =LINEST(known_y_range, known_x_range^{1,2}, TRUE, TRUE) into an empty cell. This formula returns the full regression matrix—including quadratic coefficients, standard errors, R2, and ANOVA sums of squares—using native worksheet calculations.
What is the maximum polynomial order Excel can fit in a chart trendline?
The maximum polynomial order supported by an Excel XY Scatter chart trendline is order 6 (a sextic polynomial). The minimum order is order 2 (a quadratic curve). If your data requires higher-order fitting beyond degree 6, you must create explicit power columns in the worksheet and evaluate the model using matrix algebra or external statistical software such as R or Python.
Why does LINEST return coefficients in reverse order?
Microsoft Excel designs LINEST to return coefficients in descending order of polynomial power: {m_k, m_{k-1}, ..., m_1, b}. The highest exponent term appears in the first (leftmost) column, while the constant intercept appears in the final (rightmost) column. This convention aligns with standard polynomial mathematical notation, where expressions are ordered from highest degree to lowest degree.
How do you decide the best polynomial degree for a dataset in Excel?
To determine the optimal polynomial degree in Excel, begin with a linear model (degree 1) and sequentially add quadratic (degree 2) and cubic (degree 3) terms. At each step, examine two criteria: the Adjusted R Square and the p-value of the highest-order coefficient. If adding a higher power fails to increase Adjusted R Square or yields a coefficient p-value greater than 0.05, retain the simpler, lower-degree model to avoid overfitting.
Why does the Excel trendline equation give wrong answers when calculated by hand?
The trendline equation displayed on an Excel chart truncates floating-point numbers to 2 to 4 significant digits by default. When predictor values are raised to powers, this rounding creates massive prediction discrepancies. To resolve this, right-click the trendline label, select Format Trendline Label, set Number category to Scientific or Number with 12 decimal places, or use the LINEST formula to obtain full IEEE 754 precision.
Can Excel perform polynomial regression with multiple independent variables?
Yes. Excel can perform polynomial regression with multiple predictors (for example, a response surface model containing X1, X12, X2, X22, and the interaction term X1X2). To do this, calculate each power and interaction term in separate worksheet columns, then supply the entire block of columns as the Input X Range in the Analysis ToolPak Regression tool.
Sources
- Microsoft Learn. “WorksheetFunction.LinEst Method (Excel).” Microsoft Corporation. https://learn.microsoft.com/en-us/office/vba/api/excel.worksheetfunction.linest. Accessed 2026-11-15.
- Microsoft Learn. “Trendlines.Add Method (Excel).” Microsoft Corporation. https://learn.microsoft.com/en-us/office/vba/api/excel.trendlines.add. Accessed 2026-11-15.
- National Institute of Standards and Technology (NIST). “NIST/SEMATECH e-Handbook of Statistical Methods: Section 4.1.4.1 Polynomial Models.” U.S. Department of Commerce. https://www.itl.nist.gov/div898/handbook/pmd/section1/pmd141.htm. Accessed 2026-11-15.
- National Institute of Standards and Technology (NIST). “NIST/SEMATECH e-Handbook of Statistical Methods: Section 4.4.1 Linear Least Squares.” U.S. Department of Commerce. https://www.itl.nist.gov/div898/handbook/pmd/section4/pmd41.htm. Accessed 2026-11-15.
- R Core Team. “Fitting Linear Models (stats::lm).” Comprehensive R Archive Network (CRAN). https://stat.ethz.ch/R-manual/R-patched/library/stats/html/lm.html. Accessed 2026-11-15.
- NumPy Developers. “NumPy Reference Documentation: Polynomial Package.” NumPy.org. https://numpy.org/doc/stable/reference/routines.polynomials.html. Accessed 2026-11-15.
- SciPy Community. “SciPy Reference Guide: Non-linear least squares curve fitting (scipy.optimize.curve_fit).” SciPy.org. https://docs.scipy.org/doc/scipy/reference/generated/scipy.optimize.curve_fit.html. Accessed 2026-11-15.
- The Document Foundation. “LibreOffice Calc Help: Array Functions – LINEST.” LibreOffice.org. https://help.libreoffice.org/latest/en-US/text/scalc/01/04060107.html. Accessed 2026-11-15.
Data: Polynomial Regression Implementation Parameters and Diagnostic Capabilities Across Statistical Software
Comparison of polynomial regression capabilities, maximum native order limits, linear solver methods, orthogonal polynomial decomposition, and diagnostic standard error outputs across spreadsheet and statistical software platforms, compiled from vendor documentation and statistical standards.
Period covered: 2024/2026. Coverage: Global.
| Software Platform | Maximum Native Chart Degree (degree) | Estimation Algorithm | Orthogonal Polynomial Support | Coefficient Standard Errors | Multicollinearity Safeguards |
|---|---|---|---|---|---|
| Microsoft Excel (LINEST & Trendline) | 6 | Modified Gram-Schmidt / QR Decomposition | Manual transformation via formula | 5-row array matrix via Stats=TRUE | Warning flags; user mean-centering required |
| R (stats package lm) | 25 | QR Decomposition with LINPACK/LAPACK pivoting | Built-in via poly(x, degree) | summary.lm standard errors, t-values, and p-values | Automatic column pivoting and rank deficiency detection |
| Python (NumPy / SciPy) | 50 | Singular Value Decomposition (SVD) | Built-in Chebyshev, Legendre, Hermite, Laguerre | Covariance matrix via cov=True or statsmodels OLS | Automatic domain scaling and affine coordinate shift |
| LibreOffice Calc (LINEST & Trendline) | 3 | Ordinary Least Squares via QR factorization | Manual transformation via formula | Basic LINEST 5-row statistics matrix | Basic pivot tolerance checks |
| GNU PSPP (REGRESSION) | 20 | Sweep Operator / QR Factorization | Manual polynomial syntax | Standard error, t-statistic, collinearity diagnostics | Tolerance and Variance Inflation Factor (VIF) limits |
Sources
- Microsoft Learn: WorksheetFunction.LinEst Method (Excel) (accessed 2026-11-15)
- Microsoft Learn: Trendlines.Add Method (Excel) (accessed 2026-11-15)
- R Core Team: Fitting Linear Models (stats::lm) (accessed 2026-11-15)
- NumPy Reference: Polynomial Package (accessed 2026-11-15)
- NIST/SEMATECH e-Handbook of Statistical Methods: Section 4.1.4.1 Polynomial Models (accessed 2026-11-15)
- LibreOffice Calc Help: LINEST Function (accessed 2026-11-15)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.







