Rubber Dam Frame: What It Is, Materials and How to Read a Listing

What a rubber dam frame is, how FDA classifies it (product code EJE, Class I), common materials, and a sourced checklist for comparing frame listings.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

General product and regulatory information only. This page is not medical or dental advice and does not describe clinical procedures.

Short answer

A rubber dam frame is the holder that keeps a dental rubber dam sheet stretched outside the mouth. FDA names it as one of four parts of the rubber dam device under 21 CFR 872.6300, alongside the dam, the clamp and the clamp forceps. That regulation places the whole device in Class I and exempts it from premarket notification. A frame listing is easiest to compare by material, radiolucency, stated sterilization method, sizes and MRI statement.

Definition and scope

Under 21 CFR 872.6300, “Rubber dam and accessories” (checked 2026-10-31), the device is “composed of a thin sheet of latex with a hole in the center” and is intended to isolate a tooth from fluids in the mouth during dental procedures. The regulation states that the device includes “the rubber dam, rubber dam clamp, rubber dam frame, and forceps for a rubber dam clamp.” The frame is therefore a named component, not a separate invention and not a synonym for the clamp.

The classification section says the device is Class I (general controls), exempt from the premarket notification procedures in subpart E of part 807 subject to 872.9. If it is not labeled or represented as sterile, it is also exempt from the quality management system requirements of part 820 except records and complaint files under 820.35. The FDA product code for the frame is EJE (“Frame, Rubber Dam”), as shown in the NLM database below. For the dam itself and the full four-part table, see what a rubber dam is.

How a frame is used in practice

The frame sits outside the mouth and holds the dam sheet stretched. One distributor listing for a plastic frame (Henry Schein Australia, Orsing frame, checked 2026-10-31) states that the plastic is radiolucent. That is a supplier statement about one product, not a property of every frame. Placement and removal steps are clinical technique and are outside the scope of this page.

Types and materials

Two sourced descriptions show the range. The GMDN generic term definition for “rubber dam frame,” reproduced in the NLM record, says such frames are “typically made of a thick stainless steel U-shaped rod.” The NLM record also lists a frame sold as a “Radiolucent Rubber Dam Frame,” and the distributor listing above describes a plastic one.

Frame description Source What the source states
Typical metal frame GMDN term definition, shown in NLM AccessGUDID (checked 2026-10-31) Typically a thick stainless steel U-shaped rod
Radiolucent frame (Pulpdent model RDF) NLM AccessGUDID record D701RDF2 (checked 2026-10-31) Described as “Radiolucent Rubber Dam Frame”; product code EJE
Plastic frame (Orsing, Nygaard Oestby design) Henry Schein Australia listing SV-176000 (checked 2026-10-31) Made of plastic; described as radiolucent

Reading a frame listing: a sourced checklist

The NLM AccessGUDID record for the Pulpdent frame shows what a regulator-linked record does and does not tell a buyer. It states: packaged as sterile, No; requires sterilization prior to use, Yes; sterilization method listed, high-level disinfectant; labeling does not contain MRI safety information; and “No Device Sizes.” Using that record as the model, these are the fields to look for in any frame listing:

  • Product code and regulation. The record should show EJE, “Frame, Rubber Dam.”
  • Material. Stainless steel or plastic, stated by the maker or distributor. The NLM record for the Pulpdent frame gives a name (“Radiolucent”) rather than a material.
  • Radiolucency claim. Stated or not. Treat it as a manufacturer claim.
  • Sterile status and reprocessing statement. The NLM record says the frame is not packaged sterile and requires sterilization prior to use. Listings can differ from each other: the NLM record names high-level disinfectant, while the Orsing listing says the frame can be dry-heat sterilised and autoclaved. The product’s own instructions for use are the document that settles which applies; this page does not state cycle parameters. For general background on two of these methods, see dry-heat sterilizer vs autoclave.
  • Sizes. The NLM record lists none. A listing that gives sizes should say what they refer to.
  • MRI statement. The NLM record says the labeling has no MRI safety information. Absence of a statement is not a safety claim either way.

Where it matters for labs, clinics and supply decisions

Because 21 CFR 872.6300 treats the frame as part of a Class I exempt device, a frame does not need a 510(k) clearance. The regulation’s quality-system exemption applies only if the product is not labeled or represented as sterile, so a frame marketed as sterile is outside that particular exemption. Two statements on a listing therefore deserve a close read: whether it is represented as sterile, and what reprocessing it describes. Staff who maintain instrument sets can use the checklist above to compare listings on the same fields. Latex content of the dam is a separate question, covered in the guide on latex-free dental dam; the 872.6300 definition itself describes the dam as latex.

Common misunderstandings

The frame is not the clamp

The clamp and the clamp forceps are separate named parts of the same regulated device. The frame holds the sheet; it is not the metal clamp placed on the tooth.

The frame is not the dam

The dam is the thin sheet with a hole. The frame is a separate accessory.

Class I exempt does not mean “no requirements”

The regulation places the device under general controls and makes the exemption subject to 872.9. What the exemption removes is the premarket notification step.

“Radiolucent” is a listing claim

The NLM record and the distributor listing both use the word, but neither is an FDA finding about image quality.

FAQ

What is a rubber dam frame?

It is the accessory that holds the dam sheet stretched outside the mouth, and it is named in 21 CFR 872.6300 as one of the device’s four parts.

What is the FDA product code for a rubber dam frame?

EJE, “Frame, Rubber Dam,” as shown in the NLM AccessGUDID record checked 2026-10-31.

Does a rubber dam frame come sterile?

The NLM record for the Pulpdent frame says it is not packaged sterile and requires sterilization before use. Other products may differ; the product’s instructions for use state its own status.

What are frames made of?

The GMDN definition says typically thick stainless steel U-shaped rod; one distributor lists a plastic radiolucent frame.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Rubber Dam Frame: What It Is, Materials and How to Read a Listing

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →