Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
Short answer
A salt spray test (also called a salt fog test) exposes metal or coated-metal specimens to a continuously generated saltwater mist inside a closed chamber, so that relative corrosion resistance can be compared under controlled, repeatable conditions. The best-known method is ASTM B117, and ISO 9227 is the widely used international counterpart. It ranks samples against each other; on its own it does not tell you how many years a part will last outdoors.
Definition and scope
ASTM B117 (the edition listed on the ASTM store as of 2026-11-13 is B117-26, from committee G01 on corrosion of metals) covers the apparatus, the procedure and the conditions needed to create and maintain a salt spray environment. Its stated purpose is to supply a controlled corrosive environment that yields relative corrosion-resistance information for metals and coated metals tested in a given chamber. The apparatus is described in an appendix of the standard.
The scope statement is as important for what it leaves out. According to the ASTM abstract, B117 does not prescribe the type of specimen, the length of exposure for a given product, or how the results are to be interpreted. Those decisions belong to the product specification, customer requirement or test plan that calls up the method. Anyone writing a laboratory procedure around the test needs to know this split, because the phrase “passed ASTM B117” is incomplete without the hours, the specimen preparation and the acceptance criterion that went with it.
Typical users are automotive, construction, aerospace, consumer-goods and electronics manufacturers and paint and coating producers (Q-Lab lists these industries). In a research setting the test is a screening tool for coatings, platings, conversion layers and passivation treatments; see the related guides on corrosion-protective coatings and passivation of stainless steel.
How the test is run in practice
The conditions below are those published by Q-Lab (an instrument maker) and Infinita Lab (a testing laboratory) for the neutral salt spray method in B117. They are summarised here for orientation; the standard itself is the controlling document.
- Solution: 5% sodium chloride in distilled or deionized water, with pH at 6.5 to 7.2 measured at the collection temperature. If the pH is off, it is adjusted with dilute acetic acid or sodium hydroxide.
- Chamber temperature: 35 °C, with a tolerance of ±2 °C.
- Fog: compressed air and salt solution are fed to a nozzle that atomizes the solution continuously. Fog collectors verify the rate: 1 to 2 mL per hour, measured over an 80 cm² horizontal collection area (a 10 cm funnel).
- Specimen placement: specimens are cleaned beforehand, held roughly 15 to 30 degrees from vertical, and kept from touching each other or the chamber walls. Dissimilar materials whose corrosion products could contaminate neighbouring specimens should not share a cabinet.
- Coated specimens: these are often scribed through to the substrate so that corrosion creep from the cut can be assessed.
What the standard decides and what the specification decides
Because B117 is an environment standard rather than a product standard, test reports are only comparable when the second column below is also stated. The split is drawn from the ASTM abstract and the Infinita Lab guide.
| Decided by the test method (B117) | Decided by the product specification, customer or test plan |
|---|---|
| Apparatus and chamber construction | Specimen type, size and surface preparation |
| Salt solution concentration, pH and water quality | Exposure duration in hours |
| Chamber temperature and fog collection rate | Acceptance and rejection criteria |
| General rules for specimen arrangement | Which rating method is used to evaluate the result |
Typical rating methods named by Infinita Lab for evaluating exposed specimens are ASTM D1654 (corrosion creep from a scribe), ASTM D714 (degree of blistering) and ASTM D610 (degree of rusting), often with photographic documentation.
Neutral, acetic acid and copper-accelerated tests, and cyclic variants
Neutral salt spray (NSS) is only one of several fog tests. ISO 9227 defines NSS, acetic acid salt spray (AASS) and copper-accelerated acetic acid salt spray (CASS), and ASTM G85 defines modified tests, some of which cycle between fog, dry and humid phases. The data table below this article compares the solution, pH, temperature and cycle of each as tabulated by the testing laboratory Micomlab. Use it to see how quickly the tests diverge from plain B117: the acidified tests run at pH 2.8 to 3.3 rather than neutral, CASS runs hotter at 50 °C and adds copper chloride, and the G85 cyclic tests alternate fog with dry-air or humid periods.
Infinita Lab also points to cyclic methods such as SAE J2334 and GMW14872 as alternatives used where steady fog is considered too unrealistic. Choosing among these is a specification decision, not a laboratory preference.
Reading the results and their limits
ASTM states in the B117 significance section that results from the test used alone have seldom been correlated with performance in natural environments, and that correlation or extrapolation is not always predictable. It advises considering such links only where long-term atmospheric exposures support them. Reproducibility also depends on specimen type, the evaluation criteria and control of operating variables; ASTM notes that similar specimens in different chambers under nominally similar conditions have shown variability, and recommends enough replicates to judge scatter.
Q-Lab lists further limits: the constant 35 °C fog does not reproduce humidity and temperature swings, complex salts or pollutants; a neutral solution can miss corrosion driven by acid or alkaline conditions; the test is focused on surface behaviour; and a coating that survives may still fail under UV or cyclic outdoor exposure. Infinita Lab summarises the position as a quality screen and comparative tool, not a service-life predictor, and notes there is no universal conversion from chamber hours to years in service.
Checklist for planning a salt spray test
Each item traces to the sources listed at the end of the page.
- Write down the governing standard and edition (for example B117-26 or the ISO 9227 version named by the customer) and the specification that sets duration and acceptance. B117 does not supply these.
- Define the specimen type, geometry and cleaning method, and whether coated specimens are scribed.
- Decide the number of replicates up front; ASTM ties reproducibility to replication and to control of operating variables.
- Prepare solution from distilled or deionized water at the specified concentration, and check pH at collection temperature.
- Check chamber temperature and measure fog collection (1 to 2 mL/h over the stated area) with collectors before relying on a run.
- Position specimens at the stated angle without contact with each other or the walls, and keep dissimilar metals that could cross-contaminate in separate runs.
- Name the rating method (for example D1654, D714 or D610) and record photographs at each inspection.
- Report the result as relative performance in that chamber and test type, not as a service-life estimate. For laboratory write-ups, a standard operating procedure can hold these decisions in one controlled document.
Common misunderstandings
“A part that passes 1,000 hours will last a set number of years”
No source supports a fixed hours-to-years conversion. Infinita Lab states there is none, and ASTM cautions that correlation to natural exposure is not reliably predictable from the salt spray result alone.
“B117 sets the pass mark”
It does not. Duration and acceptance come from the product specification or customer requirement.
“All salt spray tests are the same”
Neutral, acetic acid, copper-accelerated and cyclic tests differ in pH, temperature and cycle, and results from one are not interchangeable with another. Corrosion modes such as stress corrosion cracking are also outside what a surface-focused fog test is designed to show.
“The same coating gives the same result in any chamber”
ASTM reports variability between chambers even under nominally similar conditions, which is why chamber verification, replicates and clear reporting matter. The same logic applies to replicates in other lab disciplines.
Frequently asked questions
What is a salt spray test?
A corrosion test in which specimens sit in a closed chamber filled with a continuously atomized saltwater fog, used to compare the corrosion resistance of metals and coatings under controlled conditions.
What is ASTM B117?
The ASTM standard that covers the apparatus, procedure and conditions for creating and maintaining a salt spray (fog) environment. It does not set specimen type, exposure time or interpretation of results.
What temperature and salt concentration are used?
For the neutral test in B117, published summaries give 35 °C (±2 °C) and 5% sodium chloride at pH 6.5 to 7.2.
How long does a salt spray test last?
It depends on the specification that calls for the test; B117 itself does not fix a duration.
What is the difference between ASTM B117 and ISO 9227?
Both are salt spray methods. ISO 9227 covers neutral (NSS), acetic acid (AASS) and copper-accelerated (CASS) tests; see the data table for the tabulated differences in solution, pH and temperature.
Can salt spray results predict service life?
No. Sources describe the test as a relative, comparative screen rather than a service-life predictor.
Sources
- ASTM International, B117-26 Standard Practice for Operating Salt Spray (Fog) Apparatus, abstract page, read 2026-11-13.
- Q-Lab, ASTM B117 salt spray test, read 2026-11-13.
- Infinita Lab, ASTM B117 salt spray test guide, read 2026-11-13.
- Micomlab, Corrosion testing guide: table of standards, read 2026-11-13 (source of the ISO 9227 and ASTM G85 parameters in the data table).
Data: Salt fog corrosion test types: solution, pH, temperature and cycle (ASTM B117, ASTM G85, ISO 9227)
Compares the neutral, acidified, copper-accelerated and cyclic salt fog test types by solution, pH, chamber temperature and cycle, as tabulated by a corrosion testing laboratory and cross-checked against Q-Lab for B117.
Period covered: 2026.
| Test type | Solution | pH | Chamber temperature (°C) | Cycle |
|---|---|---|---|---|
| ASTM B117 (neutral salt spray) | 5% NaCl (±1%) | 6.5-7.2 | 35 ±2 | Continuous fog |
| ISO 9227 NSS | Sodium chloride | 6.5-7.2 | 35 ±2 | Continuous fog |
| ISO 9227 AASS | Sodium chloride with acetic acid | 3.1-3.3 | 35 ±2 | Continuous fog |
| ISO 9227 CASS | Sodium chloride with 0.26 g/L CuCl2·2H2O | 3.1-3.3 | 50 ±2 | Continuous fog |
| ASTM G85 A1 | NaCl with acetic acid | 3.1-3.3 | 35 ±2 | Continuous fog |
| ASTM G85 A2 | 5 ± 1% NaCl | 2.8-3.0 | 49 ±2 (fog phase) | 0.75 h fog, 2 h dry air purge, 3.25 h humidity |
| ASTM G85 A3 | Synthetic sea salt | 2.8-3.0 | 24 to 35 or 49 ±2 (fog phase) | 0.5 h fog, 1.5 h humidity |
| ASTM G85 A5 | 0.35% (NH4)2SO4 + 0.05% NaCl | 5.0-5.4 | 35 ±1.5 | 1 h fog, 1 h dry |
Sources
- Micomlab corrosion testing guide: table of standards (accessed 2026-11-13)
- Q-Lab ASTM B117 (accessed 2026-11-13)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.