SEM Sample Preparation: Fixation, Drying and Coating

SEM sample preparation compared across three university core facilities, with the artefact each fixation, drying and coating step prevents.

Written and maintained by CASRAI Editorial Board

Published

On this page

SEM sample preparation is the set of steps that turns a specimen into something a scanning electron microscope can image: it must survive high vacuum, keep its surface structure, and conduct electrons. For biological material the core workflow is chemical fixation (an aldehyde, usually followed by osmium), gradual dehydration in ethanol or acetone, drying by critical point drying or hexamethyldisilazane (HMDS), mounting on a metal stub, and a sputter coat of about 10 nm of metal.

This page compares the routes published by three university core facilities, explains what each step prevents, and links each artefact to the step that causes it. It describes laboratory practice for researchers and lab staff; follow your own facility’s validated protocol and safety rules for the actual work.

Definition and scope

A scanning electron microscope (SEM) images a surface by scanning a focused electron beam across it in a vacuum. The University of Gothenburg’s Centre for Cellular Imaging notes that SEM needs a conductive surface and high vacuum, which is why biological specimens cannot be imaged in their native, hydrated state and have to be prepared first. The preparation therefore has two jobs: preserve the structure you want to see, and make the sample compatible with the instrument.

The review “Scanning Electron Microscopy” in Current Protocols (2024;4(5):e1034) frames the method the same way: SEM gives topographical visualisation, but chemical processing can induce artefacts, so the choice of fixation matters, proper dehydration minimises shrinkage and is needed for the high vacuum, and the choice of mounting substrate and coating reduces charging. Those three concerns (artefacts from chemistry, shrinkage and drying damage, and charging) organise the rest of this page.

Scope: this page covers preparation for surface imaging (topography) of fixed biological specimens and the main alternatives. It does not cover thin sectioning for transmission electron microscopy; see TEM sample preparation and resolution and the instrument comparison in SEM vs TEM.

What are the steps of SEM sample preparation?

The Utah State University Microscopy Core Facility protocol “Biological Sample Fixation for SEM” and the Gothenburg core-facility page describe the same sequence of six stages for topography. The sections below take them in order. The data table after this guide sets the two protocols and the Cambridge facility’s description side by side.

1. Primary fixation with an aldehyde

Gothenburg describes primary fixation with an aldehyde, which crosslinks proteins and holds the structure in place. In the Utah State protocol the sample is fixed in 2% buffered glutaraldehyde overnight, with the fixative at 10 to 20 times the volume of the sample, then rinsed three times for 5 minutes each in 0.1 M HEPES buffer with gentle agitation.

2. Secondary fixation with osmium

Gothenburg lists osmium as the secondary fixative, acting on lipids. It also notes a second benefit: the black precipitate osmium leaves raises the sample’s conductivity and so reduces charging. Utah State post-fixes tissue in 1 to 2% osmium tetroxide for 1 hour and states that the step can be skipped for non-tissue samples. The two sources therefore agree that osmium is part of the standard biological route, and Utah State is the one that sets out an explicit exception.

3. Dehydration

Gothenburg specifies ethanol or acetone, applied gradually so the specimen does not shrink. Utah State uses an ethanol series: 50%, 70% and 95% ethanol twice for 10 minutes each, then 100% ethanol three times for 15 minutes each, all with agitation. Dehydration is required because water cannot be present in the high-vacuum chamber, and the stepwise gradient is what keeps shrinkage down.

4. Drying: critical point drying or HMDS

Gothenburg explains why drying is a step of its own: if the specimen simply dries from ethanol or acetone, the high surface tension of the evaporating liquid causes micro-ripping of the surface. The solvent is therefore replaced, either with HMDS (suited to cells; Gothenburg gives roughly a 3 minute incubation and then evaporation) or with liquid CO2 in a critical point drier.

Utah State offers both routes. For chemical drying it runs three ethanol:HMDS mixtures of 15 minutes each (2:1, 1:1, then 1:2), then HMDS alone for 15 minutes three times, and lets the last HMDS evaporate overnight in a fume hood. For critical point drying the Cambridge Department of Biology facility describes the sequence: fixed specimens (formaldehyde, glutaraldehyde, osmium) are washed in deionised water and dehydrated, commonly in ethanol; small specimens go into microporous capsules so they are not lost; the chamber is flushed with liquid CO2; and temperature and pressure are raised past the critical point. Cambridge adds that some materials can be processed unfixed.

5. Mounting

Gothenburg mounts the dried specimen on a metal stub with a sticky carbon disc, with silver glue as an optional extra. Utah State likewise mounts on specimen stubs before coating. The stub and the conductive path from sample to stub matter for charging, which the Current Protocols review lists as something the choice of mounting substrate helps to reduce.

6. Sputter coating

Both facilities coat the sample with a thin metal film: Utah State specifies 10 nm of gold/palladium, and Gothenburg says gold is the most common coating at about 10 nm, thick enough to prevent charging but not so thick that it obscures surface detail. Cambridge also lists sputter coating and carbon coating among the services it provides for specimen preparation.

Which preparation route fits which sample?

The decision table below connects the type of sample to the route the three facilities describe. Every row comes from the sources named in the last column; it is a map of what the sources say, not a substitute for a facility’s validated protocol.

Sample Route the sources describe Why, according to the source Source
Tissue Aldehyde fixation, osmium post-fixation, ethanol series, critical point drying or HMDS, stub, ~10 nm coat Osmium stabilises lipids and its precipitate raises conductivity Utah State; Gothenburg
Non-tissue sample that is still fixed Same route, with the osmium post-fix omitted Utah State states the osmium step can be skipped for non-tissue samples Utah State
Cells (for example grown on coverslips) Chemical drying with HMDS, or critical point drying Gothenburg names HMDS as suited to cells; Cambridge lists coverslip-grown cells among CPD samples Gothenburg; Cambridge
Small organisms or hydrogel particles Critical point drying with the specimens enclosed in microporous capsules Prevents the specimens being lost during processing Cambridge
Thin samples, fixed or unfixed, or samples to be fractured Rinse in cold deionised water, plunge-freeze in liquid ethane, optionally fracture under liquid nitrogen, freeze-dry, then mount and coat Fast route; best for thin samples because freezing rate falls with depth, increasing ice crystal damage Cambridge
Serial sections for array tomography Sections collected on conductive silicon wafers or glass rather than grids Gothenburg describes this as the alternative to surface topography imaging Gothenburg

Why each step exists: cause and artefact

Preparation artefacts are easier to recognise when you know which step produces them. The table links each problem named in the sources to the step that prevents it.

Problem in the image or sample Cause named by the source Step that addresses it
Charging of the specimen SEM needs a conductive surface; biological material is not conductive Osmium (precipitate raises conductivity), mounting on a stub with carbon disc, sputter coating (Gothenburg; Current Protocols)
Shrinkage Abrupt removal of water from the specimen Gradual dehydration in an ethanol or acetone series (Gothenburg; Current Protocols)
Micro-ripping of the surface High surface tension of the evaporating ethanol or acetone Replacing the solvent with HMDS or liquid CO2 critical point drying (Gothenburg)
Ice crystal damage in freeze-dried samples Freezing rate declines with depth in the sample Use thin samples, or keep the area of interest near the surface (Cambridge)
Obscured surface detail Coating that is too thick Coat to about 10 nm, thick enough to prevent charging but not to hide detail (Gothenburg)
Chemical artefacts Chemical processing itself Choice of fixation method (Current Protocols)

Where it matters for labs and supply decisions

Preparation is a chain of dedicated equipment and consumables, and the sources show where a lab needs them. Critical point drying needs a critical point drier with specimen boats or microporous capsules (Cambridge describes a Quorum E3100 with boats about 75 mm long and 12 mm in diameter). The plunge-freezing route needs liquid ethane, liquid nitrogen, LN2-cooled brass inserts and a freeze dryer; Cambridge states a run holds up to 6 larger or 8 flat samples depending on the insert. Both routes end at a sputter coater, mounting stubs and carbon discs.

Where a facility offers these as services, preparation can be handed to staff: Cambridge notes that it supplies the fixatives, staining, dehydration and resin embedding for TEM, tailors protocols to the sample type and asks users to consult early in a project. Keeping the protocol written down as a controlled procedure helps repeatability; see standard operating procedure (SOP). For the instrument itself, electron microscope cost covers the purchase side, and electron microscopy grids covers the specimen supports used in transmission work.

Common misunderstandings

“Any dehydrated sample can simply air-dry.” Gothenburg explains why not: air-drying from ethanol or acetone tears the surface through surface tension, which is the reason HMDS or critical point drying exist.

“Osmium is always required.” Utah State’s protocol applies it to tissue and states it can be skipped for non-tissue samples; Gothenburg describes it as the secondary fixative for biological topography samples.

“A thicker coating is safer.” Gothenburg’s guidance is that the coat should be thick enough to prevent charging but not so thick that it obscures detail, at about 10 nm of gold. Utah State uses 10 nm of gold/palladium.

“Freeze-drying works for any size of sample.” Cambridge states the plunge-freeze route is best suited to thin samples because ice crystal formation and structural damage increase with depth.

“One protocol fits every specimen.” The sources show variation even for the same stages (HMDS versus critical point drying, ethanol versus acetone, osmium or not), and Cambridge states that its protocols are tailored to the sample type and intended analysis.

Frequently asked questions

How to study SEM images?

Treat an SEM image as a topographical view of a prepared surface. The Current Protocols review describes SEM as giving topographical visualisation and warns that chemical processing can induce artefacts, so before interpreting a feature, check whether it could come from fixation, shrinkage during dehydration, drying damage or the coating. The artefact table above lists those links.

What are the steps of sample preparation?

For a biological specimen: aldehyde primary fixation, osmium secondary fixation (omitted for non-tissue samples in the Utah State protocol), gradual dehydration, drying by critical point drying or HMDS, mounting on a stub, and sputter coating of about 10 nm. Each step is described in the sections above, with the two facility protocols compared in the data table.

How much sample is required for TEM?

This depends on the TEM method and the facility; the SEM sources used here do not give an amount, so none is stated. Cambridge notes that its TEM preparation is tailored to the sample type and intended analysis and asks users to consult staff early. For the TEM workflow see TEM sample preparation and resolution.

What kind of stains are used for preparing specimens for an electron microscope?

In SEM preparation, the heavy-metal contrast comes mainly from osmium used as a secondary fixative, whose precipitate also raises conductivity (Gothenburg), and from the metal sputter coat. Staining of thin sections is a TEM step: Cambridge lists staining within its TEM service alongside fixation, dehydration and resin embedding. The TEM guide linked above covers that workflow.

Sources

Data: SEM sample preparation steps as described by three university core facilities

Side-by-side comparison of the fixation, dehydration, drying, mounting and coating stages for scanning electron microscopy as described in the published protocol or service pages of Utah State University, the University of Gothenburg and the University of Cambridge, compiled by CASRAI from those pages.

Period covered: 2026.

SEM sample preparation steps as described by three university core facilities
StageUtah State UniversityUniversity of GothenburgUniversity of Cambridge
Primary fixation2% buffered glutaraldehyde overnight, 10-20x sample volume; rinse 3 x 5 min in 0.1 M HEPESAldehyde fixation crosslinks proteinsFormaldehyde or glutaraldehyde for biological specimens (before critical point drying)
Secondary fixation1-2% osmium tetroxide for 1 h for tissue; skipped for non-tissueOsmium fixes lipids; black precipitate raises conductivityOsmium tetroxide listed among chemical fixatives; some materials processed unfixed
DehydrationEthanol 50, 70, 95% (2 x 10 min each), 100% (3 x 15 min)Ethanol or acetone, applied gradually to avoid shrinkageCommonly ethanol, after washing in deionised water
DryingCritical point drying, or HMDS series (2:1, 1:1, 1:2 ethanol:HMDS, 15 min each; HMDS 3 x 15 min; last HMDS evaporated overnight in fume hood)HMDS (about 3 min incubation then evaporation) or liquid CO2 critical point dryingCritical point drying with liquid CO2; or plunge-freezing in liquid ethane then freeze-drying
MountingSpecimen stubMetal stub with sticky carbon disc; silver glue optionalMounting after drying (method not specified)
CoatingSputter coat, 10 nm Au/PdSputter coat, most commonly gold, about 10 nmSputter and carbon coating offered

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about SEM Sample Preparation: Fixation, Drying and Coating

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →