Simulated Moving Bed (SMB) Chromatography Guide

Simulated moving bed (SMB) chromatography enables continuous preparative separation by cycling inlet and outlet ports across interconnected column zones.

Written and maintained by CASRAI Editorial Board

Published

On this page

Simulated moving bed (SMB) chromatography is a continuous preparative chromatographic technique that achieves countercurrent separation of binary or pseudo-binary mixtures without physically transporting the solid adsorbent. By interconnecting a series of stationary chromatographic columns in a closed loop and periodically shifting the fluid inlet and outlet ports in the direction of mobile phase flow, the system creates the hydrodynamics of a true moving bed operating at steady state with substantially reduced solvent consumption.

Definition and Operating Principles of SMB Chromatography

In conventional batch preparative liquid chromatography, a sample plug is periodically injected into the head of a single column packed with stationary phase adsorbent. As mobile phase eluent flows through the bed, components resolve into distinct bands based on differential partition coefficients and exit at distinct retention times. While mechanically straightforward, batch chromatography exhibits inherent operational inefficiencies: large sections of the column bed remain unoccupied by solute at any given moment, throughput is restricted by the requirement to elute all components before reinjection, and substantial volumes of pure solvent are consumed to flush and re-equilibrate the stationary phase between cycles.

To overcome these limitations, chemical engineers developed the theoretical concept of True Moving Bed (TMB) chromatography. In an ideal TMB process, solid adsorbent moves continuously downward through a vertical column while liquid mobile phase flows upward in a continuous countercurrent configuration. A binary mixture of components A (more strongly adsorbed) and B (less strongly adsorbed) is continuously injected at a central feed port. Under properly calibrated flow velocity ratios, component A is preferentially swept downward with the moving solid phase to emerge continuously at a bottom extract port, while component B is swept upward with the liquid stream to emerge continuously at a top raffinate port.

Although conceptually elegant, physically transporting solid chromatographic particles in a continuous loop poses severe engineering hurdles. Circulating fine adsorbent particles causes mechanical attrition, bed abrasion, non-uniform packing densities, wall channeling, and valve clogging. The Simulated Moving Bed (SMB) process circumvents these physical constraints by holding the adsorbent stationary inside multiple discrete columns arranged in series, while periodically shifting the positions of the inlet and outlet ports downstream in the direction of fluid flow. This discrete port switching replicates the relative countercurrent velocity between the solid stationary phase and the liquid eluent. As discussed in comparative assessments such as reversed-phase vs normal-phase HPLC, the underlying chromatographic retention mechanisms remain governed by partition thermodynamics, but the continuous multi-column configuration converts transient batch elutions into a continuous cyclic steady state.

The Four Operational Zones and Port Switching Dynamics

A standard Simulated Moving Bed system arranges multiple identical chromatographic columns in a continuous closed circuit divided into four distinct operational zones. The four zones are defined by the physical locations of two fluid inlet streams (Eluent and Feed) and two fluid outlet streams (Extract and Raffinate). Each zone serves a specialized hydrodynamic and thermodynamic function necessary to sustain continuous binary separation without cross-contamination:

  • Zone I (Desorption and Solid Regeneration): Located between the fresh Eluent inlet and the Extract outlet port. Zone I completely desorbs the more strongly retained component A from the stationary phase before the adsorbent bed cycles into Zone IV. To strip strongly bound molecules off the resin, the volumetric liquid flow rate in Zone I (QI) is maintained at the highest level in the system.
  • Zone II (Extract Purification and Solute Desorption): Situated between the Extract outlet and the central Feed inlet port. Zone II desorbs the less strongly retained component B from the solid phase, preventing component B from migrating backward into the Extract stream. The net fluid velocity in Zone II washes component B forward toward the Feed port while component A continues to move with the simulated solid flow toward the Extract port.
  • Zone III (Adsorption and Raffinate Purification): Located between the Feed inlet and the Raffinate outlet port. Zone III adsorbs component A from the liquid stream onto the stationary phase, preventing component A from breaking through into the Raffinate outlet. The fluid velocity allows the weakly retained component B to travel forward with the liquid flow and emerge as a purified Raffinate stream.
  • Zone IV (Adsorbent Conditioning and Eluent Regeneration): Situated between the Raffinate outlet and the Eluent inlet port. Zone IV readsorbs any residual component B from the fluid phase before the liquid stream loops back to mix with incoming fresh eluent at the Zone I boundary. Operating at the lowest internal flow rate (QIV), Zone IV purifies the circulating mobile phase, enabling continuous internal solvent recycling.

The internal volumetric flow rates strictly follow the descending hierarchy: QI > QII > QIII > QIV. The external flow rates entering and leaving the system maintain an overall mass balance governed by continuity equations:

QEluent = QI – QIV

QExtract = QI – QII

QFeed = QIII – QII

QRaffinate = QIII – QIV

At fixed time intervals designated as the switching time (ts or t*), all four fluid access ports are simultaneously shifted one column position forward in the direction of liquid flow. When the port shifts match the net migration velocities of components A and B through the beds, internal concentration profiles stabilize into a cyclic steady state where high-purity Extract and Raffinate are withdrawn continuously. Maintaining stable flow across these high-pressure transitions requires stringent control of dissolved gases; as documented in guides on degassing in HPLC, outgassing or bubble formation in multi-pump recycling loops leads to severe flow rate errors and rapid loss of zone boundary definition.

Theoretical Design Framework: The Triangle Theory

Designing, operating, and optimizing an SMB system requires quantitative determination of the internal flow rates (QI through QIV) and the port switching time (ts). In foundational chemical engineering literature, Giuseppe Storti, Marco Mazzotti, and Massimo Morbidelli developed the “Triangle Theory,” an analytical design methodology based on local equilibrium theory that establishes explicit operating boundaries for complete separation.

The transport of solutes through each zone depends on the net balance between convective fluid velocity and simulated solid velocity. This balance is represented by the dimensionless net flow rate ratio in zone j, denoted as mj:

mj = (Qj · ts – V · ε) / [V · (1 – ε)]

In this equation, Qj represents the volumetric flow rate in zone j, ts is the switching time, V is the geometric volume of a single column, and ε is the total column void fraction (bed porosity including interparticle and intraparticle voidage). The numerator reflects the net convective volume passing through the column during one switching interval minus the mobile phase holdup, while the denominator normalizes this flow against the volume of the solid stationary phase matrix.

Under linear adsorption conditions governed by Henry’s law, solute concentrations in the solid phase (qi) relate linearly to liquid concentrations (Ci) via Henry constants HA and HB (where component A is more strongly retained than component B, such that HA > HB). To achieve complete separation with 100% purity and 100% recovery for both streams, the dimensionless flow rate ratios must satisfy four fundamental inequalities:

  • Zone I condition: m1 ≥ HA (ensures complete desorption of component A from the stationary phase).
  • Zone II condition: HB < m2 ≤ HA (prevents breakthrough of component A into Zone III while desorbing component B).
  • Zone III condition: HB ≤ m3 ≤ HA (ensures complete adsorption of component A while allowing component B to elute).
  • Zone IV condition: m4 ≤ HB (ensures complete adsorption of component B to clean the recycled solvent).

Because the Feed stream introduces net positive fluid volume into the system (QFeed = QIII – QII > 0), the flow rate in Zone III must always exceed that in Zone II, establishing the physical constraint m3 > m2. When the operating bounds for m2 and m3 are plotted on a two-dimensional Cartesian plane with m2 on the horizontal axis and m3 on the vertical axis, the intersection of the constraints HB < m2 ≤ HA, HB ≤ m3 ≤ HA, and m3 > m2 forms a distinct right-angled triangle. Any operating point (m2, m3) positioned inside this triangular domain guarantees complete separation under ideal equilibrium conditions.

Operating outside the triangle results in predictable contamination modes: operating to the right of the triangle (m2 > HA) causes component A to migrate backward into the Extract stream, reducing Extract purity; operating below the diagonal (m3 < HB) causes component B to accumulate in the adsorbent, contaminating the Extract; and operating above the triangle (m3 > HA) causes component A to break through into the Raffinate stream. The apex of the separation triangle represents the optimal thermodynamic operating condition: it maximizes the difference (m3 – m2), which directly maximizes feed throughput and productivity while minimizing desorbent consumption.

Under real-world preparative conditions where feed concentrations are elevated, competitive non-linear adsorption isotherms (such as Langmuir or bi-Langmuir models) alter these boundaries. Non-linear competition distorts the linear triangle into a curved polygon whose boundaries depend directly on feed concentration. Furthermore, kinetic non-idealities—including axial dispersion, film mass transfer resistance, and intraparticle pore diffusion—round the sharp corners of the theoretical triangle, shrinking the allowable operating space into a smaller robust operating window.

Sourced Decision Table: SMB vs. Batch Preparative Chromatography

Selecting between continuous Simulated Moving Bed chromatography and conventional single-column batch preparative liquid chromatography requires evaluating process throughput, solvent recovery infrastructure, feed composition, and regulatory validation overhead. The decision table below outlines the core functional and operational differences between these two chromatographic operating models based on published process engineering criteria.

Performance Parameter Single-Column Batch Preparative HPLC Continuous Simulated Moving Bed (SMB) Engineering Implication
Operational Mode Discontinuous, sequential pulse injections with cyclic washing Continuous steady-state feed injection and product withdrawal SMB integrates seamlessly into continuous manufacturing trains; batch requires intermediate holdup vessels.
Separation Capability Multi-fraction separation (resolves 3 or more components in one run) Binary or pseudo-binary fractionation (Extract and Raffinate streams) Batch is versatile for crude multicomponent extracts; SMB excels at high-volume binary cuts (e.g. chiral enantiomers).
Solvent Consumption High (typically 20 to 50 L of mobile phase per gram of product) Low (typically 2 to 5 L of mobile phase per gram of product; 70-90% reduction) SMB drastically cuts operational expenditure for solvent procurement, storage, and downstream distillation.
Stationary Phase Utilization Low (only 10% to 25% of column bed active in separation at any moment) High (near 100% of stationary phase actively engaged in adsorption/desorption) SMB requires 50% to 80% less resin inventory for an equivalent annual production capacity.
Product Concentration Dilute peak fractions requiring substantial post-chromatographic concentration Concentrated steady-state streams; lower dilution factors Reduced downstream thermal burden and evaporator sizing for active pharmaceutical ingredients.
Capital Equipment Complexity Single high-pressure pump, one column, single multiport injection valve Multiple interconnected columns (4-16), 4 synchronized pumps, complex valve manifold Higher initial capital expenditure and instrument complexity for SMB; offset by reduced operational costs at scale.
Method Development and Control Empirical gradient or isocratic optimization via peak retention times Model-based optimization (isotherm measurement, Triangle Theory parameterization) SMB requires rigorous physico-chemical characterization of adsorption equilibria before system startup.

For research laboratories and early-phase process development where sample quantities are limited and mixtures contain complex multicomponent matrices, batch chromatography systems such as FPLC chromatography remain the standard approach because they collect multiple discrete fractions across complex elution gradients. Conversely, when a process involves isolating a high-value binary pair—such as resolving a racemic API into individual enantiomers or extracting pure paraxylene—the substantial solvent and resin savings of SMB establish clear economic superiority at pilot and commercial manufacturing scales.

Practical System Setup, Hardware and Column Configuration

Implementing a robust Simulated Moving Bed chromatography system involves coordinating specialized fluidic hardware, synchronized valve automation, and matched column sets. A typical laboratory- or pilot-scale SMB system consists of four principal sub-assemblies:

1. Column Array Configurations

An SMB circuit distributes columns across the four operational zones. Common configurations utilize 4, 8, 12, or 16 columns arranged in a closed loop. A 4-column system assigns one column per zone (1-1-1-1 configuration). While mechanically compact, 4-column systems exhibit relatively sharp concentration transients during port switching. An 8-column system distributes two columns per zone (2-2-2-2 configuration) or uses asymmetric arrangements (such as 1-2-2-1), which substantially dampens port-switching dispersion, sharpens solute concentration fronts, and widens the allowable separation window. Industrial-scale units frequently deploy 12 to 24 beds to approximate true countercurrent plug flow with minimal axial mixing.

2. Fluid Delivery and Metering Pumps

Continuous SMB operation relies on four high-precision, low-pulsation metering pumps. Two pumps deliver inlet streams: the Eluent pump supplies fresh mobile phase to Zone I, and the Feed pump continuously introduces dissolved crude mixture between Zone II and Zone III. Two pumps regulate outlet withdrawal: the Extract pump controls the withdrawal rate of the strongly adsorbed fraction between Zone I and Zone II, and the Raffinate pump governs the discharge rate of the weakly adsorbed fraction between Zone III and Zone IV. Alternatively, some commercial platforms employ three external delivery pumps combined with an internal recycling pump that circulates mobile phase through the closed loop. Precise volumetric flow control is mandatory; even small delivery errors (1-2%) can shift the operating point out of the separation triangle.

3. Valve Switching Architectures

Shifting inlet and outlet ports across columns is executed via two primary valve architectures: centralized multi-port rotary valves or distributed discrete valve arrays. Pioneered in the petrochemical UOP Sorbex process, a single specialized rotary distributing valve connects to every column inlet and outlet. Rotating the central valve disk by one indexing position simultaneously advances all four process streams to the next column position. Modern laboratory and pharmaceutical SMB platforms (such as Knauer AZURA and Novasep systems) utilize arrays of synchronized two-way or three-way high-pressure solenoid or pneumatic valves installed at the inlet and outlet of each column. Microprocessor control coordinates valve sequencing, offering high operational flexibility to modify column counts per zone or implement non-synchronous switching schemes (e.g. Varicol processes).

4. Process Analytical Technology (PAT) and Column Matching

To verify continuous separation quality in real time, SMB systems integrate non-destructive flow-through detectors at strategic points in the loop. Multi-wavelength UV/Vis detectors, differential refractometers (RI), polarimeters, and conductivity sensors monitor Extract and Raffinate purities. Because chiral enantiomers lack distinct UV spectra, polarimetric detection or online analytical HPLC sampling valves are frequently used to monitor enantiomeric excess. As reviewed in comparisons of HPLC detector selection, detector cell volume and response speed must be optimized to prevent backpressure spikes and peak broadening within preparative lines.

A critical engineering prerequisite for SMB operation is rigorous column matching. Because columns are connected in a continuous series, differences in bed packing density, particle size distribution, or bed permeability between columns disrupt the uniform propagation of concentration waves. If one column exhibits higher hydraulic resistance or lower theoretical plate efficiency, the internal flow rates deviate during that column’s cycle, causing periodic baseline oscillations and product contamination. Before assembling an SMB train, columns must undergo standardized qualification testing to confirm that retention times match within ±1.5% and column backpressures match within ±3.0%, following procedures comparable to column packing checks on automated preparative platforms like ÄKTA chromatography systems.

Industrial and Laboratory Applications

Simulated Moving Bed chromatography has transitioned from a specialized petrochemical fractionation technology into a cornerstone continuous separation process across pharmaceuticals, biotechnology, fine chemicals, and food processing:

  • Chiral API Enantiomer Resolution: Regulatory guidance (e.g. FDA policy on stereoisomeric drugs) requires thorough pharmacological characterization and commercial production of single enantiomers. When asymmetric synthesis of a single enantiomer is synthetically challenging or cost-prohibitive, SMB chromatography on immobilized chiral stationary phases (e.g. polysaccharide-based amylose or cellulose derivatives) provides an efficient route to separate racemates. SMB operates continuously at high feed concentrations, yielding optical purities exceeding 99% with solvent consumption up to 90% lower than batch HPLC.
  • Carbohydrate and Sugar Refining: The food and beverage industry utilizes large-scale SMB systems (the UOP Sarex process and modern ion-exchange SMB units) to separate fructose from glucose in high-fructose corn syrup (HFCS) production. Utilizing calcium-form sulfonated polystyrene cation exchange resins, fructose forms a weak, reversible complex with calcium ions, eluting in the Extract stream while glucose elutes in the Raffinate.
  • Natural Product and Cannabinoid Processing: In botanical extraction, SMB enables selective depletion or enrichment of closely related target phytocannabinoids. For instance, continuous 4-column SMB systems using green ethanol/water mobile phases selectively deplete tetrahydrocannabinol (THC) from hemp extract down to compliant non-detectable levels while recovering purified cannabidiol (CBD) at >97.8% purity, slashing solvent usage from 41.05 L/g in batch to 3.29 L/g in continuous mode.
  • Petrochemical Hydrocarbon Isomer Separation: The historical foundation of SMB lies in the petrochemical UOP Parex process, which separates paraxylene from mixed C8 aromatic isomers (orthoxylene, metaxylene, and ethylbenzene) using zeolitic molecular sieves. Because the boiling points of xylene isomers are virtually identical, fractional distillation is energetically prohibitive; SMB continuous adsorption isolates pure paraxylene for polyester synthesis.
  • Biopharmaceuticals and Protein Purification: In bioprocessing, continuous chromatography variants such as Multi-Column Countercurrent Solvent Gradient Purification (MCSGP) and periodic countercurrent chromatography (PCC) adapt SMB principles to capture and polish monoclonal antibodies, recombinant proteins, and synthetic oligonucleotides, maximizing Protein A resin utilization.

The data table below compares performance metrics, solvent reduction rates, and productivity multipliers across five primary industrial SMB application domains.

Common Operational Challenges and Troubleshooting

Maintaining long-term cyclic steady-state performance in an SMB system requires active surveillance of hydrodynamic balance, valve integrity, and column health. When purity or recovery declines, operators should investigate the following common failure modes:

  • Operating Point Drift Outside the Separation Triangle: The most frequent cause of product contamination is incorrect setting or drifting of internal zone flow rates. If the Extract fraction becomes contaminated with weakly retained component B, Zone II flow rate (QII) is insufficient to wash component B forward, or switching time (ts) is too long. If the Raffinate fraction contains strongly retained component A, Zone III flow rate (QIII) is too high, carrying component A forward past the Raffinate port. Operators should recalculate m2 and m3 values against measured adsorption isotherms and readjust pump rates.
  • Column Permeability Mismatch and Bed Compaction: Over extended operating hours, particulate accumulation or mechanical compaction can increase hydraulic resistance in individual columns. In an SMB loop, an elevated pressure drop in one column causes cyclical pressure surges each time that column shifts across zones, distorting pump delivery rates. Regularly monitoring individual column pressure transducers during port transitions identifies fouling early. Guard column replacement or column repacking is required if permeability deviates by more than 5%.
  • Valve Port Leakage and Dead Volume Dispersion: Valve seat wear in multi-port rotary valves or solenoid manifolds allows internal cross-leakage between high-pressure zones (Zone I) and low-pressure zones (Zone IV). Even minor fluid leakage across valve ports bypasses the column beds, creating baseline tailing and immediate purity drops. Routine pressure decay testing of valve manifolds and minimizing interconnecting tubing lengths are critical preventive maintenance tasks.
  • Stationary Phase Aging and Irreversible Adsorption: Crude feedstocks often contain non-target strongly binding impurities (such as lipids, polyphenols, or heavy tars) that do not desorb under standard Zone I conditions. Over time, these impurities accumulate at the column inlets, blocking active adsorption sites and altering the effective Henry constants. Implementing pre-column solid-phase extraction, sacrificial guard cartridges, or automated periodic regeneration flushes preserves primary column longevity.

Frequently asked questions

What is the difference between SMB chromatography and moving bed chromatography?

True moving bed (TMB) chromatography physically transports solid adsorbent countercurrently against an upward-flowing liquid stream within a single vessel. Because circulating solid particles causes severe mechanical attrition, channeling, and equipment wear, simulated moving bed (SMB) chromatography keeps the solid adsorbent packed inside fixed columns and periodically shifts the fluid inlet and outlet ports in the direction of liquid flow, replicating true countercurrent hydrodynamics without physical particle movement.

Why is SMB chromatography primarily restricted to binary separations?

Standard four-zone SMB chromatography uses two inlet ports (Eluent and Feed) and two outlet ports (Extract and Raffinate), dividing the feed mixture into exactly two fractions: a more strongly adsorbed component and a less strongly adsorbed component. Separating ternary or multicomponent mixtures into three or more pure individual fractions requires cascading multiple SMB units in series, utilizing specialized multi-zone configurations (e.g. 5-zone or 8-zone systems), or operating in intermittent gradient modes such as MCSGP.

How much solvent does SMB chromatography typically save compared to batch HPLC?

Continuous SMB chromatography typically reduces mobile phase solvent consumption by 70% to 90% compared to conventional single-column batch preparative HPLC. These substantial savings result from continuous internal recycling of the mobile phase in Zone IV, higher stationary phase loading capacity, and the elimination of solvent-intensive column wash and re-equilibration cycles between sample injections.

What happens if the switching time in an SMB system is too fast or too slow?

The switching time governs the simulated velocity of the solid phase relative to the liquid flow. If the switching time is too fast, the simulated solid moves downstream too rapidly, dragging the weakly adsorbed component B into Zone I and contaminating the Extract stream. If the switching time is too slow, the mobile phase sweeps the strongly adsorbed component A forward into Zone III, contaminating the Raffinate stream. Both extremes collapse product purity.

Can gradient elution be implemented in simulated moving bed chromatography?

Standard four-zone SMB operates isocratically, as the continuous recycling of mobile phase from Zone IV into Zone I requires a uniform solvent composition. However, advanced continuous systems implement solvent gradients through specialized architectures, such as Multi-Column Countercurrent Solvent Gradient Purification (MCSGP) or supercritical fluid SMB (SF-SMB), which introduce secondary modifier streams or pressure gradients across discrete columns.

What is the role of the Triangle Theory in SMB process development?

The Triangle Theory is an analytical and graphical design framework developed by Storti, Mazzotti, and Morbidelli that defines the exact range of internal flow rate ratios (m2 and m3) required to achieve 100% purity and recovery for both extract and raffinate streams under equilibrium conditions. It eliminates trial-and-error experimentation by allowing engineers to calculate optimal pump flow rates and switching times directly from measured adsorption isotherms.

Sources

  • Rajendran A, Paredes G, Mazzotti M. Simulated moving bed chromatography for the separation of enantiomers. Journal of Chromatography A. 2009; 1216(4): 709–738. DOI: https://doi.org/10.1016/j.chroma.2008.10.075 (Accessed 2026-11-14).
  • Mazzotti M, Storti G, Morbidelli M. Optimal operation of simulated moving bed units for counter-current adsorption of two-component mixtures. Journal of Chromatography A. 1997; 769(1): 3–24. DOI: https://doi.org/10.1016/S0021-9673(97)00048-4 (Accessed 2026-11-14).
  • KNAUER Wissenschaftliche Geräte GmbH. AZURA SMB Systems: Preparative and Continuous Liquid Chromatography Technical Documentation. URL: https://www.knauer.net/en/Systems-Solutions/Preparative-HPLC/Simulated-Moving-Bed-SMB (Accessed 2026-11-14).
  • Compagnin G, De Luca C, Nosengo C, Greco G, Catani M, Cavazzini A, Krauke Y, Felletti S. Continuous Depletion of Tetrahydrocannabinol From Cannabis Extract Through Simulated Moving Bed Chromatography Using Green Mobile Phase. Journal of Separation Science. 2025; 48(5): e70175. DOI: https://doi.org/10.1002/jssc.70175 (Accessed 2026-11-14).
  • Broughton DB, Neuzil RW, Pharis JM, Brearley CS. The Parex process for recovering paraxylene. Chemical Engineering Progress. 1970; 66(9): 70–75 (Accessed 2026-11-14).
  • Ruthven DM, Ching CB. Counter-current and simulated counter-current adsorption separation processes. Chemical Engineering Science. 1989; 44(5): 1011–1038. DOI: https://doi.org/10.1016/0009-2509(89)85001-7 (Accessed 2026-11-14).

Data: Continuous SMB vs Batch Preparative Chromatography Performance Comparison

Comparative empirical operational benchmarks, solvent consumption, resin utilization, and productivity multipliers contrasting continuous simulated moving bed (SMB) chromatography against traditional single-column batch preparative HPLC across published pharmaceutical, biochemical, and specialty chemical separation processes.

Period covered: 1970-2026. Coverage: Global.

Continuous SMB vs Batch Preparative Chromatography Performance Comparison
Separation ApplicationColumn SetupSolvent Consumption Reduction (%)Productivity Multiplier (fold)Stationary Phase Savings (%)Typical Product Purity (%)Typical Product Recovery (%)
Chiral API Enantiomer Resolution8 columns (2-2-2-2)853.86599.298.5
Cannabinoid Depletion (CBD/THC)4 columns (1-1-1-1)921.25097.898.8
Carbohydrate Fractionation (Glucose/Fructose)12 columns (3-3-3-3)754.5609895
Petrochemical Xylene Isomers (p-Xylene)24 beds rotary8057099.796.5
Recombinant Protein / Biologic Capture4 columns (1-1-1-1)702.54598.594

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Simulated Moving Bed (SMB) Chromatography Guide

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →