Skip to main content
v2026.11,986 entries · CC-BY 4.0

Specific Activity: Enzyme U/mg, Katal and Radioactivity

Specific activity is units per mg of protein for enzymes and activity per unit mass for radionuclides; see the U to katal conversion and a worked example.

Written and maintained by CASRAI Editorial Board

Published

On this page

Specific activity is activity per unit mass. For an enzyme preparation it is the number of enzyme units per milligram of protein (U/mg), where one unit converts 1 µmol of substrate per minute. For a radionuclide it is the radioactivity per unit mass of that nuclide, usually expressed in becquerel per gram or per mole. The two meanings share a name but not a unit system, so the first job in reading any “specific activity” value is to establish which one is meant.

Short answer

In biochemistry, specific activity = enzyme units ÷ mg of protein. One unit (U) is the amount of enzyme that catalyses the conversion of 1 µmol of substrate, or the formation of 1 µmol of product, in 1 minute. In radiochemistry and radioactive-materials regulation, specific activity is the activity of a radionuclide per unit mass of that nuclide, or of a material in which it is uniformly distributed. The SI unit for catalytic activity is the katal (mol/s); for radioactive decay it is the becquerel (s-1).

Definition and scope

The enzyme definition is stated plainly in a 2022 open-access paper on parameter reliability in enzymology: one unit of enzyme activity is the amount catalysing the conversion of 1 µmol of substrate (or the formation of 1 µmol of product) in 1 minute, and the specific activity of an enzyme preparation is the number of units per mg protein (Molecules 2022, PMC8746786). The ratio is useful because it normalises catalytic activity to the amount of protein present, so two batches of the same enzyme, or two purification steps, can be compared even when the total protein differs.

The same wording, “specific activity”, appears in a second, unrelated setting. The US Code of Federal Regulations defines it for radioactive material shipping: the specific activity of a radionuclide means the activity of the radionuclide per unit mass of that nuclide, and the specific activity of a material in which the radionuclide is essentially uniformly distributed is the activity per unit mass of the material (49 CFR 173.403). Here “activity” means decays per second, not catalytic turnover.

This page covers both meanings but concentrates on the enzyme usage, including the enzyme unit and its conversion to SI. For protein quantitation, which supplies the denominator of the enzyme calculation, see the guide to protein assays. For decay calculations on a radionuclide, see the radioactivity calculator guide.

How specific activity is calculated and reported for enzymes

The calculation

Two measurements are needed: the enzyme activity of the sample in units, and the mass of protein in the same sample. Divide the first by the second. The activity measurement comes from an assay in which product forms (or substrate disappears) at a measured rate under defined conditions; the protein mass comes from a separate protein determination.

A teaching page from the University of Glasgow expresses the same idea as a working formula: specific activity equals the enzyme units divided by the volume of sample (µl) multiplied by the protein concentration (mg/ml) divided by 1000, so that the denominator is milligrams of protein actually assayed.

Worked example (illustrative numbers)

The figures below are invented for illustration and do not describe any real enzyme or product.

  • A reaction mixture is found to contain 5 U of activity. The aliquot added was 10 µl of a preparation at 2 mg/ml protein.
  • Protein in the aliquot: 10 µl × 2 mg/ml ÷ 1000 = 0.02 mg.
  • Specific activity: 5 U ÷ 0.02 mg = 250 U/mg.

Because the protein concentration sits in the denominator, any error in the protein assay carries straight into the specific activity. A stock whose protein is overestimated will look less active than it is.

Why the definition of the unit matters

The same 2022 paper warns that some workers use the word “unit” for more arbitrary measurements, such as absorbance change per unit time per mg of enzyme protein, and concludes that the units used must be defined in any publication. A value of “120 units/mg” is therefore only comparable to another value when both rest on the same unit definition. If a supplier or paper does not say what its unit is, the number cannot be converted or compared with confidence.

Enzyme units, the katal and conversion between them

The enzyme unit predates the SI approach to catalytic activity. In 1999 the 21st General Conference on Weights and Measures (CGPM, Resolution 12) noted that a non-SI unit called “unit”, symbol U and equal to 1 µmol·min-1, “has been in widespread use in medicine and biochemistry since 1964 for expressing catalytic activity”. It adopted the special name katal, symbol kat, for the SI unit mole per second, to express catalytic activity especially in medicine and biochemistry (SI Brochure, 9th edition, 2019). The SI Brochure’s table of derived units lists catalytic activity in kat (mol s-1) and catalytic activity concentration in kat m-3 (mol s-1 m-3).

The CGPM resolution adds a condition that is easy to miss: when the katal is used, the measurand should be specified by reference to the measurement procedure, and that procedure must identify the indicator reaction. A katal value without the reaction behind it is incomplete in the same way a unit without a definition is.

The 2022 paper gives the practical relationship: the katal is 1 mol of substrate per second, which it describes as inconveniently large; 1 kat = 60 mol/min = 6 × 107 units, and 1 U = 1 µmol/min = 16.67 nkat. It also notes that if the molar concentration of enzyme is known, activity can instead be expressed as the turnover number kcat = Vmax/e, in s-1.

Worked conversion (editorial arithmetic from the sourced factors)

Take an illustrative preparation with a specific activity of 240 U/mg. Using 1 U = 16.67 nkat, 240 U/mg × 16.67 ≈ 4,000 nkat/mg, or about 4.0 µkat/mg. Using 1 kat = 6 × 107 U, the same value is 240 ÷ (6 × 107) = 4.0 × 10-6 kat/mg. The conversion factors are sourced; the example value and the multiplication are editorial. The data table below sets the units side by side.

Specific activity of radionuclides

In radioactive-materials regulation, the quantity is defined per unit mass of the nuclide, or per unit mass of a material containing it uniformly (49 CFR 173.403, read 2026-11-12). The SI unit of activity referred to a radionuclide is the becquerel, symbol Bq, equal to s-1 (SI Brochure, 9th edition). Specific activity of a radionuclide is therefore naturally expressed as Bq per unit mass. The enzyme unit and the becquerel are different quantities: one counts conversions of substrate per time, the other counts nuclear decays per time. The katal and the becquerel both reduce to a rate (per second) in SI base terms, but they are listed as separate derived units with separate special names precisely so that they are not confused.

For a worked decay-based calculation, such as how activity changes over time, use the guide to the radioactivity calculator; for how radiolabelled samples are detected on film or screen, see autoradiography.

Where it matters in labs

  • Comparing preparations. A specific activity normalises catalytic activity to protein mass, so lots, vendors or purification stages can be compared on one scale, provided the unit and assay conditions are the same.
  • Reading a certificate or datasheet. The number is meaningful only with its unit definition and measurement procedure. The sourced guidance asks for both.
  • Writing methods and manuscripts. Units should be defined in any publication; when using the katal, name the indicator reaction. Unit style in manuscripts is covered in the guide to SI units in scientific writing.
  • Shipping radioactive material. The regulatory definition of specific activity in 49 CFR 173.403 is the one applied to transport classification, so a researcher’s informal use of the term does not substitute for it.

Reporting checklist

  1. State which meaning applies: enzyme catalytic activity per mg protein, or radioactivity per unit mass.
  2. Define the unit (for enzymes, 1 U = 1 µmol/min of substrate converted or product formed).
  3. State the basis: per mg of protein, and how the protein was measured.
  4. Name the indicator reaction or measurement procedure, particularly when reporting in katal.
  5. If converting, give the factor used (1 U = 16.67 nkat; 1 kat = 6 × 107 U).

Common misunderstandings

  • “Unit” is not one fixed thing. Where a paper or datasheet uses “unit” for something like absorbance change per time per mg, it is not the 1 µmol/min unit, and the two cannot be converted by the factors above.
  • Specific activity is not total activity. Total units describe how much catalysis a sample can do; specific activity divides by protein, so a dilute but pure enzyme and a concentrated but impure one can show different totals and different ratios.
  • The katal is not a replacement for the unit in everyday bench work. The paper calls it inconveniently large, which is why nkat or µkat and U remain common.
  • Enzyme and radionuclide specific activity are different quantities. The words are the same; the definitions, units and regulators are not.

Frequently asked questions

What is an enzyme unit?

One unit of enzyme activity is the amount that catalyses the conversion of 1 µmol of substrate, or the formation of 1 µmol of product, in 1 minute (PMC8746786). It equals 1 µmol·min-1, as noted in CGPM Resolution 12 (1999).

What are the units of specific activity?

For enzymes, units per milligram of protein (U/mg). In SI terms, katal per kilogram, or the more convenient nkat/mg or µkat/mg. For radionuclides, becquerel per unit mass.

How do I convert U/mg to nkat/mg?

Multiply by 16.67, because 1 U = 16.67 nkat (PMC8746786). To go from U to kat, divide by 6 × 107.

What is the katal?

The SI unit of catalytic activity, 1 mol of substrate per second, adopted by the 21st CGPM in 1999 with the symbol kat (SI Brochure, 9th edition).

Do I need to say which reaction was measured?

Yes. CGPM Resolution 12 recommends that when the katal is used, the measurand be specified by reference to the measurement procedure, which must identify the indicator reaction.

Is specific activity the same as kcat?

No, but they are related. If the molar concentration of enzyme is known, activity can be given as kcat = Vmax/e in s-1 (PMC8746786); specific activity instead normalises to protein mass.

Sources

  • Bureau International des Poids et Mesures, The International System of Units (SI), 9th edition (2019), table of derived units and Appendix 1, 21st CGPM (1999) Resolution 12 on the katal. bipm.org. Read 2026-11-12.
  • Parameter Reliability and Understanding Enzyme Function, Molecules 2022 (PMC8746786). pmc.ncbi.nlm.nih.gov. Read 2026-11-12.
  • 49 CFR 173.403, definitions for radioactive material transport. law.cornell.edu. Read 2026-11-12.
  • University of Glasgow, enzyme teaching page. mvls.gla.ac.uk. Read 2026-11-12.

Data: Enzyme activity units: definitions and conversion factors

Compilation of the enzyme unit, katal and nanokatal compared on a common basis (µmol of substrate per minute and mol per second), compiled from the SI Brochure 9th edition and a peer-reviewed enzymology paper. The nkat row is derived arithmetic from the sourced 1 U = 16.67 nkat factor.

Enzyme activity units: definitions and conversion factors
UnitSymbolEquivalent in units (U) (U)Equivalent rate (µmol/min)
Enzyme unitU11
Nanokatalnkat0.060.06
Katalkat6000000060000000

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Specific Activity: Enzyme U/mg, Katal and Radioactivity

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →