Starch Hydrolysis Test: Medium, Iodine Reading and QC Strains

Starch hydrolysis test explained: reading the iodine zone, the starch agar medium specification, QC strains and 21 CFR 866.2320 placement.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

General laboratory and product information, not medical advice or a validated procedure. Follow your laboratory’s SOP and the manufacturer’s instructions for use.

Short answer

The starch hydrolysis test checks whether a bacterial isolate secretes amylase, an exoenzyme that breaks starch down. Organisms are grown on starch agar, then the plate is flooded with Gram’s iodine: a colourless zone around the growth means starch was hydrolysed, while a blue or purple zone means it was not (HiMedia technical data M107S, checked 2026-10-30).

Definition and scope

Starch agar is a nutrient agar with soluble starch added, sold for the “detection of starch hydrolysing microorganisms” (HiMedia M107S). The test is a single biochemical reaction, not an identification by itself: it is read alongside other tests. In the United States such media are regulated as differential culture media, which 21 CFR 866.2320 describes as devices used to cultivate and identify types of microorganisms “by a visible change (e.g., a color change) in a specific biochemical component” (law.cornell.edu, checked 2026-10-30).

How the test works in practice

Starch is too large to cross the bacterial cell membrane. An organism that makes the exoenzyme amylase releases it into the medium, where it breaks starch into smaller sugars such as glucose and maltose. Starch is invisible in agar until iodine is added, and iodine with starch gives a dark blue to black colour (Ohio State University Microbiology Lab, LibreTexts 4.03, checked 2026-10-30).

The reading rule in the manufacturer’s data sheet: flood the surface of a 24 to 48 hour culture with Gram’s iodine; hydrolysis appears as a colourless zone around the colonies, and a blue or purple zone indicates starch was not hydrolysed (HiMedia M107S).

What the clear zone must surround

The clearing has to surround the growth itself. LibreTexts cautions that a strong hydrolyser can clear starch around a neighbouring streak, so a clear halo next to another organism’s growth is not a positive result for the organism beside it.

The medium as a manufacturer specifies it

For lab staff who stock or prepare the plate, one manufacturer’s published specification (HiMedia Starch Agar M107S) gives the following:

Item Stated specification
Meat extract 3.0 g/L
Peptic digest of animal tissue 5.0 g/L
Starch, soluble 2.0 g/L
Agar 15.0 g/L
Dehydrated medium 25 g suspended in 1000 ml
Final pH 7.2 ± 0.1 at 25°C
Sterilisation Autoclave at 15 lbs (121°C) for 10 minutes
Storage Powder below 30°C, tightly closed; prepared medium at 2-8°C; use before expiry

The data sheet marks the composition as adjusted and standardised to suit performance parameters, so other manufacturers’ formulations may differ. For background on the sterilisation step, see our guide to what an autoclave is; for another widely used plate medium, see Mueller-Hinton agar.

Quality control strains and expected results

The same data sheet lists the quality control organisms for the medium, incubated at 35-37°C for 18-48 hours with an inoculum of 50-100 CFU. Expected growth is luxuriant with recovery of at least 70%.

QC strain Expected starch result
Bacillus cereus ATCC 10876 Positive: clearing around the colony
Bacillus subtilis ATCC 6633 Positive: clearing around the colony
Escherichia coli ATCC 25922 Negative: no clearing
Staphylococcus aureus ATCC 25923 Negative: no clearing

The purpose of the panel is to run a known positive and a known negative alongside test isolates. General expectations for laboratory quality control are covered in our guide to CLIA quality control requirements, and incubation conditions depend on the incubator and the medium’s data sheet.

Where it matters for labs and supply decisions

Regulatory placement of the medium

Under 21 CFR 866.2320, a differential culture medium is Class I (general controls) and exempt from premarket notification (510(k)), subject to the limitations in section 866.9. The openFDA device classification database (record updated 2026-10-19, checked 2026-10-30) lists product code JSF, “Culture Media, Single Biochemical Test”, under regulation number 866.2320 in the Microbiology specialty.

Standards history

HiMedia states the medium was formulated by Vedder in 1915 for Neisseria (J Infect Dis 1915;16:385) and that its present formulation is accepted by the Bureau of Indian Standards (IS 5887 Part IV, 1976) for detecting starch hydrolysis by Bacillus cereus.

Common misunderstandings

  • A clear zone anywhere on the plate is a positive. It must surround the organism’s own growth (see above).
  • Starch clearing is visible before iodine is added. Starch is not visible until iodine is flooded onto the surface (LibreTexts 4.03).
  • A blue or purple zone means the organism did not grow. Per the data sheet it means starch was not hydrolysed; growth and hydrolysis are separate observations.
  • One result identifies the organism. It is one differential biochemical reaction.

FAQ

What does a positive starch hydrolysis test look like?

A colourless zone around the colonies after the plate is flooded with Gram’s iodine (HiMedia M107S).

What does a negative result look like?

A blue or purple zone, meaning starch remains (HiMedia M107S).

Which enzyme is being detected?

Amylase, an exoenzyme that breaks starch into smaller sugars such as glucose and maltose (LibreTexts 4.03).

Is starch agar a regulated device?

In the US, a differential culture medium falls under 21 CFR 866.2320 as a Class I device exempt from 510(k) premarket notification, with the limitations in section 866.9 (checked 2026-10-30).

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Starch Hydrolysis Test: Medium, Iodine Reading and QC Strains

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →