Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
General laboratory information from a manufacturer’s instructions for use and the US Code of Federal Regulations. It is not medical advice and not a bench procedure; follow the instructions for use supplied with your own reagent and your laboratory’s approved SOP.
Short answer
The hippurate hydrolysis test is a qualitative biochemical test that shows whether a bacterial isolate produces hippuricase, an enzyme that splits sodium hippurate into glycine and benzoic acid. Ninhydrin reacts with the glycine to give a blue to purple colour, which is read within a set time window. One manufacturer’s disk lists beta-hemolytic streptococci, Gardnerella vaginalis and Campylobacter jejuni as its intended targets.
Definition and scope
Hippurate hydrolysis is one of the biochemical reactions a clinical microbiology laboratory can use to help differentiate organisms. In the United States, reagent-based identification products of this type fall under 21 CFR 866.2660, “Microorganism differentiation and identification device”, which describes components such as differential culture media, biochemical reagents and paper discs or strips impregnated with test reagents that are used to differentiate and identify selected microorganisms and aid in the diagnosis of disease. The regulation classifies the device as Class I (general controls) and exempts it from premarket notification, subject to 21 CFR 866.9 (eCFR, checked 2026-10-31).
The Thermo Fisher Remel Hippurate Disk (R21085) is labelled for in vitro diagnostic use by trained individuals. It is a reagent-impregnated disk with sodium hippurate as the reactive ingredient, supplied at 25 disks per vial (instructions for use, checked 2026-10-31).
How it works in practice
According to the disk’s instructions for use, the chemistry has two stages. First, hippuricase hydrolyses hippuric acid to glycine and benzoic acid. Second, ninhydrin deaminates the glycine, and a condensation reaction produces a final purple-coloured complex. The colour is read within the time window set by the instructions. The bench steps are in the manufacturer’s instructions for use and are not reproduced here.
Reading criteria on the disk instructions
- Positive: blue to purple colour development within 30 minutes.
- Negative: light grey colour development or no colour change within 30 minutes.
The time window is part of the criterion. A different reagent format, such as a tube method with a hippurate solution, carries its own incubation and reading times in its own instructions, so a laboratory SOP should match the reagent it actually stocks.
Related concepts
The same ninhydrin reaction is the classic way of detecting free amino groups; see CASRAI’s guide to bacteriology for the wider setting of biochemical identification. Reagent kits of this kind are in vitro diagnostic products, and the IVD clinical trials entry explains how such products are studied before use. For how a test’s accuracy depends on the sample it is used on, see spectrum bias in diagnostic accuracy.
Where it matters for labs and supply decisions
Every row below comes from the Remel disk instructions for use (checked 2026-10-31) unless marked as the regulation. It is a checklist of what the document states, not buying advice.
| Item | What the source states |
|---|---|
| Regulatory class | Class I, exempt from premarket notification, subject to 21 CFR 866.9 (21 CFR 866.2660) |
| Intended use | Qualitative detection of sodium hippurate hydrolysis by beta-hemolytic streptococci, G. vaginalis and C. jejuni; in vitro diagnostic use by trained individuals |
| Storage | Store at 2-8 °C; let the vial equilibrate to room temperature before use |
| Signs of deterioration | Do not use if the disk is no longer white, the product is expired, or the desiccant has changed from blue to pink |
| Not supplied | Plastic tubes, forceps, ninhydrin reagent, demineralised water, incubator and quality control organisms |
| Tubes | Use plastic tubes; glass may yield a false-negative result |
| Quality control | Control organisms: G. vaginalis ATCC 14018 positive, S. agalactiae ATCC 12386 positive, S. pyogenes ATCC 19615 negative |
| Aberrant QC | If aberrant quality control results are noted, patient results should not be reported |
One practical consequence of the “not supplied” row: the disk is one part of a working test. Ninhydrin, plastic tubes, an incubator and control strains are separate items that the laboratory has to have in place, and the controls must be run with each group of tests.
Common misunderstandings
- A purple result is not a species identification. The disk is labelled for qualitative detection of hippurate hydrolysis; the result is one reaction among the characteristics a laboratory uses.
- The reading time is not optional. The instructions define positive and negative by the colour seen within 30 minutes.
- Any tube will do. The instructions specify plastic tubes because glass may give a false negative.
- A disk that looks fine is fine. The instructions list colour change of the disk, expiry and desiccant colour as reasons to discard it.
FAQ
What does a positive hippurate hydrolysis test mean?
It means hippuricase hydrolysed sodium hippurate and the released glycine reacted with ninhydrin, giving blue to purple colour within 30 minutes on the Remel disk instructions.
Which organisms is the hippurate disk intended for?
The Remel disk is intended for detecting hippurate hydrolysis by beta-hemolytic streptococci, Gardnerella vaginalis and Campylobacter jejuni.
Can the test be run in glass tubes?
The instructions say plastic tubes should be used, because glass may yield a false-negative result.
Is the reagent a regulated medical device?
Products of this type are described in 21 CFR 866.2660, which classifies microorganism differentiation and identification devices as Class I and exempt from premarket notification, subject to 21 CFR 866.9.
Sources
- Thermo Fisher Scientific, Remel Hippurate Disk instructions for use (R21085), documents.thermofisher.com, checked 2026-10-31.
- 21 CFR 866.2660, Microorganism differentiation and identification device, eCFR, checked 2026-10-31.