Written and maintained by CASRAI Editorial Board
Published
On this page
Stomatal conductance (gs, or gsw when it refers specifically to water vapour) is a measure of how readily gas, chiefly water vapour leaving and CO₂ entering, passes through the stomata of a leaf per unit leaf area. It is reported on a leaf-area basis, in mol m⁻² s⁻¹ or, more often in the literature, mmol m⁻² s⁻¹. Instruments do not read it directly: they measure humidity, air flow, leaf temperature and leaf area, then calculate it.
Short answer
Stomatal conductance estimates the rate of gas exchange through leaf stomata per unit difference in mole fraction between the leaf interior and the surrounding air. Its reciprocal is stomatal resistance. Because it is derived from other readings, two numbers called gs can differ by instrument, by how the boundary layer is handled and by the unit basis, which is why a method section must name all three. The table in the data section below sets out the units and the quantities that are easily confused.
Definition and scope
The conductance describes the combined effect of stomatal aperture and stomatal density, and to a lesser extent pore depth, with a small direct effect of temperature, as summarised in the encyclopaedic overview listed in the sources. It is a leaf-level property of gas diffusion, not a count of open stomata and not a direct measure of the pore width.
Conductance and resistance
Stomatal resistance is the inverse of conductance. A porometer described in that overview obtains conductance by taking the reciprocal of the measured resistance (g = 1/R). Older papers often report resistance, so a literature comparison starts by converting everything to one form.
gsw, gtw and the boundary layer
Three related quantities appear in instrument manuals. Total conductance to water vapour (gtw) is calculated from the transpiration rate and the water vapour mole fraction inside the leaf. The boundary layer conductance (gblw) is the part contributed by the still air at the leaf surface. Stomatal conductance (gsw) is what remains once the boundary layer has been separated out. LI-COR’s theory-of-operation page for the LI-600 states that calculating gsw from gtw requires separating the boundary layer conductance.
Units
The Prometheus protocol on steady-state porometers gives gsw in mol air m⁻² s⁻¹, where the mole is a mole of air rather than of water vapour. Because 1 mol = 1000 mmol, a value written in mmol m⁻² s⁻¹ is the same quantity scaled by 1000. Older volumetric conductances in m s⁻¹ (or mm s⁻¹, multiplied by 10⁻³ first) are converted to the molar form by dividing by the molar volume of air, RT/ptot, which is why they depend on temperature and pressure.
How stomatal conductance is measured in practice
Gas-exchange instruments follow the same chain of reasoning, set out in LI-COR’s description of the LI-600:
- Direct readings. Relative humidity sensors on either side of the leaf cuvette, air flow, a non-contact infrared reading of leaf temperature, reference temperature and atmospheric pressure.
- Apparent transpiration (E). Computed from the water vapour difference across the cuvette and the molar flow of air entering it. Leaf area is needed, entered directly or calculated from leaf width and a geometry factor, to express the result per unit area.
- Total conductance (gtw). Calculated from E and the mole fraction of water vapour in the leaf interior, which is taken from saturation vapour pressure at leaf temperature.
- Stomatal conductance (gsw). Obtained from gtw after the boundary layer conductance is separated out. In the LI-600 the boundary layer conductance is characterised as a polynomial function of cuvette flow rate using a temperature-controlled water source, on the assumption that it is the only limitation to E in that characterisation.
The Prometheus protocol writes the same logic as four equations in a steady-state porometer: gsw = gtw / (1 − rogtw), where ro is the non-stomatal resistance to water vapour, usually taken as boundary-layer resistance; gtw = E(1 − 0.5(wi + wa)) / (wi − wa), where wi and wa are the intercellular and ambient water vapour mole fractions; wi is the saturation vapour pressure at leaf temperature divided by total pressure, which assumes the leaf interior is saturated; and E = (fin/a)(wout − win)/(1 − wout), where a is leaf area in the chamber and fin is the inflow rate.
Types of porometer
Porometers are usually grouped by how they obtain the water vapour flux. The descriptions below are from the two sources named in each case.
Steady-state porometers
A steady-state porometer infers conductance from how much leaf transpiration raises the humidity of a constant air stream through the chamber. The Prometheus protocol notes that a measurement takes roughly one minute, so the stomata have little time to respond to chamber conditions. The encyclopaedic overview describes a variant with a sensor head containing a fixed diffusion path, where vapour concentration at two points and the known path conductance give the flux.
Null-balance porometers
A null-balance porometer modulates the flow rate to seek a chamber humidity setpoint. This needs feedback control but allows chamber humidity to match ambient conditions. The Prometheus protocol adds that changes in the evaporative gradient alter leaf temperature through evaporative cooling, which reduces the accuracy of the setpoint.
Dynamic porometers
A dynamic porometer times how long the humidity in a chamber clamped to the leaf takes to rise from one value to another, and derives resistance from that interval, the cup length and an offset constant (encyclopaedic overview).
Infrared gas analyser systems
Open-flow systems such as the LI-600, which LI-COR describes as a steady-state open flow-through gas exchange system, are built around the humidity-difference mass balance in the previous section. Photosynthesis systems that use an infrared gas analyser (IRGA) can report conductance from the same kind of calculation, and the comparison in the next section concerns porometers versus IRGAs.
What controls stomatal conductance
The factors below are taken from the encyclopaedic overview and are listed so that a protocol can record the conditions that move the number, not as a substitute for the primary physiology literature.
- Guard cell turgor. Opening is tied directly to guard cell turgor, regulated by active osmotic changes.
- Light. C3 and C4 plants open stomata as light increases; CAM plants open them as light decreases. Blue light acts through a receptor that drives proton pumping and potassium uptake.
- CO₂. Guard cell photosynthesis responds to CO₂ entering the chloroplasts, and CO₂ at the leaf surface is an input to the Ball-Berry-Leuning model.
- Humidity and vapour pressure deficit. Vapour pressure deficit is a term in the same model.
- Abscisic acid (ABA). Triggered by drought, it helps close stomata, reducing water loss but also limiting CO₂ uptake.
- Xylem cavitation. It reduces conductance while water potential stays stable.
- Night-time regulation. Conductance at night is actively regulated and has a circadian component.
Method differences: porometer versus infrared gas analyser
Toro, Flexas and Escalona (2019, Theoretical and Experimental Plant Physiology 31: 483–492) compared leaf porometer and IRGA readings of gs in sunflower, maize, bean and grapevine under two water regimes and two environmental conditions, with measurements on both leaf surfaces. The two instruments gave different values, and the gap depended on species, water status and environment. Under maximum water stress the porometer readings were higher than the IRGA readings in all four species. The authors conclude that the method itself affects the result.
The practical consequence for a lab is that values from different instruments are not interchangeable without a documented comparison, and a pooled dataset should record the instrument model and method on every row. The Prometheus protocol supplies several reasons such differences can arise.
Known error sources listed for steady-state porometers
- Boundary layer. ro is often estimated with wet filter paper, a practice the protocol says has been questioned (Grace, 1989). Error is greatest when ro or gsw is large; strong chamber fans reduce it.
- Leaf temperature. A fine-wire thermocouple reads a weighted average of leaf and air temperature with unknown weights. An infrared sensor is limited by leaf emissivity and reference-temperature error.
- Cuticular transpiration. The equations ignore it, so if its gradient matches the stomatal gradient the reported value is the sum of cuticular and stomatal conductance.
- Desiccant. Drierite and silica gel adsorb CO₂, so measurement time should be short to avoid a stomatal response to CO₂ change, and the humidity sensor should be re-zeroed whenever desiccant is replaced.
- Leaks and adsorptive materials. Positive pressure makes leaks advective rather than diffusive; chamber and tubing should not adsorb water vapour, and the protocol names Bev-A-Line tubing as highly adsorptive.
- Humidity sensors. Capacitive sensors need periodic calibration and can drift; chilled-mirror hygrometers can foul from dust or airborne oils.
Where it matters for lab protocols and records
For a research office or a lab manager, stomatal conductance is a case where the number depends on the procedure. A standard operating procedure that fixes the instrument, the flow or chamber settings, the leaf surface measured, the leaf-area entry and the time of day makes later readings comparable inside one lab, while the method comparison above shows why they may not be comparable across labs. Controlled growth conditions affect the readings too; see the CASRAI guide to controlled environments for plant science for how growth conditions are specified, and the guide to phenomics and high-throughput phenotyping for the context in which conductance is sometimes collected at scale. Documenting the method also supports methods reproducibility, and the field background is in what botany covers.
Reporting checklist drawn from the sources
- Instrument type (steady-state, null-balance, dynamic, or IRGA-based) and model, since method affects the result.
- Units and basis: mol or mmol, per square metre of leaf, mol of air, and whether the value is gsw or gtw.
- How the boundary layer was handled: a value of ro or a flow-based characterisation.
- How leaf temperature was obtained (thermocouple or infrared) and how leaf area was set.
- Leaf surface and the environmental conditions, including light and vapour pressure deficit.
- Desiccant handling and humidity-sensor zeroing if a desiccant system is used.
Common misunderstandings
It is not stomatal aperture. Aperture and density both contribute, but the reported number is a conductance calculated from humidity, flow, temperature and area.
It is not a continuous record. The Prometheus protocol describes a porometer reading as a brief snapshot of gsw on one leaf at one moment, and says scaling it to larger spatial and temporal scales is difficult.
The mole is not water. The molar unit is moles of air, so conversion from volumetric units uses the molar volume of air.
The result may include more than the stomata. When cuticular transpiration is ignored by the equations, it is folded into the reported value under the condition stated above.
Instruments agree only to a point. Agreement between a porometer and an IRGA cannot be assumed, as the 2019 comparison shows for water-stressed plants.
Sources
- LI-COR: LI-600 theory of operation, equation summary, checked 2026-11-16
- Prometheus Protocols: Design of steady-state porometers for measuring leaf stomatal conductance, checked 2026-11-16
- Wikipedia: Stomatal conductance, checked 2026-11-16
- Toro, Flexas and Escalona (2019), Theoretical and Experimental Plant Physiology: Contrasting leaf porometer and infra-red gas analyser methodologies, checked 2026-11-16
Data: Stomatal conductance: quantities, units and how they relate
Compares the conductance and resistance quantities that appear in leaf gas-exchange methods: what each describes, its unit or basis, and how it is derived. Compiled from the LI-COR LI-600 theory of operation, the Prometheus Protocols steady-state porometer protocol and the Wikipedia article on stomatal conductance.
| Quantity | What it describes | Unit or basis | Relation to other quantities | Source |
|---|---|---|---|---|
| Stomatal conductance to water vapour (g_sw) | Leaf-level gas diffusion through stomata, boundary layer removed | mol air m-2 s-1 (often written mmol m-2 s-1; 1 mol = 1000 mmol) | Calculated from g_tw after separating boundary layer conductance | LI-COR LI-600; Prometheus Protocols |
| Total conductance to water vapour (g_tw) | Stomata plus boundary layer | Same molar basis as g_sw | Calculated from transpiration E and leaf-interior mole fraction | LI-COR LI-600; Prometheus Protocols |
| Boundary layer conductance (g_blw) | Still-air layer at the leaf surface | Same molar basis | Characterised as a polynomial function of cuvette flow rate (LI-600) | LI-COR LI-600 |
| Stomatal resistance | Inverse of conductance | Reciprocal of the conductance unit | g = 1/R | Wikipedia: Stomatal conductance |
| Volumetric conductance | Older convention | m s-1 (mm s-1 x 10^-3 first) | Divide by molar volume of air, RT/p_tot, to get the molar form | Prometheus Protocols |
| Apparent transpiration (E) | Water vapour flux per unit leaf area | mol m-2 s-1 (LI-600 mass balance) | From humidity difference across the cuvette and molar air flow | LI-COR LI-600; Prometheus Protocols |
Sources
- LI-COR: LI-600 theory of operation (accessed 2026-11-16)
- Prometheus Protocols: steady-state porometers (accessed 2026-11-16)
- Wikipedia: Stomatal conductance (accessed 2026-11-16)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.







