Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop stool sample container supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

Stool Sample Container: Types, Preservatives and FDA Class

What a stool sample container is, how the FDA classifies it, and how dry containers differ from formalin and PVA preservative vials.

Written and maintained by CASRAI Editorial Board

Published · Last updated

This page describes products and general use; it is not medical advice.

On this page

A stool sample container is the sealed vessel a stool specimen is collected into and carried to a laboratory. Clinic staff, buyers and students use this page to see what the container must do, how the FDA classifies it, and how the container differs when a preservative is involved.

What a stool sample container is

A stool sample container is a clean, dry, leakproof vessel for collecting a stool specimen. The CDC’s parasitology reference (DPDx) tells laboratories to collect stool “in a dry, clean, leakproof container” and to make sure no urine, water, soil or other material gets into it. Its purpose is to deliver the specimen to the laboratory in a condition that can still be examined.

Who uses it: clinical and parasitology laboratories, clinics and other sites that collect specimens, and the patients or staff who fill the container before it is sent to a lab.

How it is built and regulated

In US federal regulation a stool container can fall under the device category “microbiological specimen collection and transport device” (21 CFR 866.2900). The regulation defines it as a specimen collecting chamber intended for medical purposes, meant to preserve the viability or integrity of microorganisms in specimens during storage after collection and during transport from the collecting area to the laboratory. It adds that the device may be labeled or represented as sterile and that it aids in the diagnosis of disease caused by pathogenic microorganisms.

The device is Class I, which means general controls apply. A device of this type is exempt from premarket notification (510(k)) when it is intended solely for collecting concentrated parasites from specimens and transporting them, subject to the limitations in 21 CFR 866.9. Materials, closure type and capacity are set by each manufacturer, so read the instructions for use supplied with the product.

Types and variants

The CDC separates plain collection from collection into a preservative.

Type Typical use Key difference (CDC DPDx)
Dry, clean, leakproof container Collecting a fresh stool specimen Holds a fresh specimen with no preservative; the CDC specifies that it be dry, clean and leakproof.
Vial with 10% formalin Preserving a specimen that cannot be examined in the prescribed time Good preservation of helminth eggs, larvae and protozoan cysts; compatible with immunoassay kits; inadequate preservation of protozoan trophozoite morphology and can interfere with PCR, especially after extended fixation.
Vial with PVA (polyvinyl alcohol) Preserving a specimen for protozoa The low-viscosity form (LV-PVA) gives good preservation of the morphology of protozoan trophozoites and cysts.
Commercial two-vial kit Dividing one specimen between formalin and PVA The two preservatives have complementary advantages, so the CDC describes splitting a specimen between them; commercial two-vial kits are available for this.

The CDC also lists other preservatives, such as SAF and MIF, each with its own advantages and drawbacks. If the laboratory needs PCR, the CDC points to its separate molecular-diagnosis guidance for collection, preservation and shipping.

How to choose

Two rules apply. First, if a commercial collection kit is used, follow the kit’s instructions. Second, the preservative must suit what the laboratory will do with the specimen, because formalin and PVA preserve different organisms well and formalin can interfere with PCR. The practical consequence is that the ordering laboratory, not the container’s shape, decides which container is correct. Ask the laboratory which container and preservative it requires before collecting.

Safe use and handling basics

  • Use a dry, clean, leakproof container, and keep urine, water, soil and other material out of it.
  • Seal the container well. The CDC suggests reinforcing the seal with parafilm or another suitable material, then placing the container in a plastic bag.
  • The CDC notes that preserved specimens can be stored for several months.

For labeling, transport and chain-of-custody, see specimen container requirements and specimen labeling error prevention. For the outer pouch, see biohazard specimen bags.

Common mistakes

  • Letting urine, water or soil enter the container, which the CDC warns against.
  • Leaving the lid under-sealed, or skipping the secondary bag.
  • Putting the specimen into a preservative when the laboratory wanted a fresh specimen, or the reverse. Formalin, for example, can interfere with PCR.
  • Ignoring a kit’s own instructions when a commercial kit is used.

FAQ

What is a stool sample container called by the FDA?

A microbiological specimen collection and transport device, Class I, under 21 CFR 866.2900.

Does the container have to be sterile?

The regulation says the device may be labeled or represented as sterile; it does not require every container to be. The CDC’s stated requirement for stool collection is a dry, clean, leakproof container.

Why do some containers hold liquid?

Those vials contain a preservative such as 10% formalin or PVA, used when a specimen cannot be examined in the prescribed time.

Can I use any clean jar?

The CDC specifies a dry, clean, leakproof container and does not describe substitutes. Use the container the ordering laboratory specifies, and follow the kit’s instructions if a kit is supplied.

Related reading: what is parasitology, biospecimen.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Stool Sample Container: Types, Preservatives and FDA Class

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →