Written and maintained by CASRAI Editorial Board
Published · Last updated
This page describes products and general use; it is not medical advice.
On this page
A stool occult blood test is a diagnostic kit that detects blood in stool in amounts too small to see. In US regulatory terms it is a Class II device under 21 CFR 864.6550. Two kit types are in common use, guaiac-based (gFOBT) and immunochemical (FIT), and they differ in sample count and in which part of the gut they point to. Who uses it: clinic and laboratory staff who stock or hand out the kits, buyers who need to read the regulatory record, and students learning the product class.
What a stool occult blood test is
Under 21 CFR 864.6550(a), an occult blood test is “a device used to detect occult blood in urine or feces.” The regulation defines occult blood as blood present in such small quantities that it can be detected only by chemical tests of suspected material, or by microscopic or spectroscopic examination (Cornell LII copy of the CFR, checked 2026-11-03). This page covers the stool (fecal) kits.
How the two kit types work
The American Cancer Society describes two stool-based blood tests (checked 2026-11-03).
Guaiac-based test (gFOBT)
The gFOBT finds hidden blood in stool through a chemical reaction. It checks more than one stool sample. Unlike the FIT, it cannot tell whether the blood comes from the colon or from other parts of the digestive tract.
Fecal immunochemical test (FIT)
The FIT checks for hidden blood in stool from the lower intestines. It is done at home, and the American Cancer Society states that it “does not have any drug or dietary restrictions.” It is less likely than the gFOBT to react to bleeding from the upper parts of the digestive tract.
Types and variants
| Type | What the source says | Key difference |
|---|---|---|
| gFOBT (guaiac-based) | Chemical reaction; checks more than one stool sample | Cannot tell colon blood from blood elsewhere in the digestive tract |
| FIT (immunochemical) | Checks for hidden blood from the lower intestines; no drug or dietary restrictions | Points to the lower intestines |
Source for both rows: American Cancer Society, “Screening Tests for Colorectal Cancer”, checked 2026-11-03. The ACS recommends that only the highly sensitive versions of the gFOBT be used.
FDA classification and product codes
21 CFR 864.6550(b) classifies the occult blood test as Class II (special controls). A control intended for use with an occult blood test is exempt from premarket notification (510(k)) under subpart E of part 807, subject to the limits in 21 CFR 864.9. The openFDA device classification database lists these product codes under regulation 864.6550, all Class 2 in the Hematology panel (queried 2026-11-03):
| Product code | Device name in the FDA record |
|---|---|
| KHE | Reagent, Occult Blood |
| GGG | Guaiac Reagent |
| NGK | Test, Occult Blood, Over The Counter |
| OSL | Control, Fecal Occult Blood |
| OOX | Automated Occult Blood Analyzer |
| JIP | Blood, Occult, Enzymatic Method, In Urine |
| JIO | Blood, Occult, Colorimetric, In Urine |
The last two codes cover urine tests rather than stool kits. For background on the wider category see what an in vitro diagnostic is and what counts as a medical device.
How to read a kit’s regulatory record
The FDA record gives a product a regulation number, a class and a product code, and the codes above separate over-the-counter tests (NGK), reagents (KHE, GGG), controls (OSL) and analyzers (OOX). Home kits sit in a different place from tests run by staff; point-of-care testing and CLIA-waived tests explain how the setting changes the rules. Supplies of this kind are catalogued under diagnostic, monitoring and imaging supplies.
Stool occult blood test uses
The American Cancer Society lists the FIT and the gFOBT among the stool-based tests used in colorectal cancer screening. These tests look for hidden blood in stool and can be done at home. The FDA’s home use tests page says home tests are intended to help with health care but should not replace periodic visits to a doctor (checked 2026-11-03).
Handling and labeling basics
- A kit is supplied with its own instructions; the instructions packed with the specific kit govern its use.
- The product code and class on the FDA record identify what kind of device a kit is (see the table above).
FAQ
What is a stool occult blood test?
It is a device that detects blood in stool too small to see, classified by the FDA as a Class II device under 21 CFR 864.6550.
What is the difference between gFOBT and FIT?
The gFOBT is a chemical reaction test that checks more than one stool sample and cannot say where in the digestive tract the blood came from. The FIT checks for blood from the lower intestines and has no drug or dietary restrictions (American Cancer Society).
Is a stool occult blood test regulated by the FDA?
Yes. 21 CFR 864.6550 places it in Class II (special controls); controls used with it are exempt from 510(k) subject to 21 CFR 864.9 limits.
What are stool occult blood test uses?
The American Cancer Society lists the FIT and gFOBT among the stool-based tests used in colorectal cancer screening.
Sources
- 21 CFR 864.6550, Occult blood test, Cornell Legal Information Institute, checked 2026-11-03.
- openFDA device classification API, regulation 864.6550, queried 2026-11-03.
- American Cancer Society, Screening Tests for Colorectal Cancer, checked 2026-11-03.
- US FDA, Home Use Tests, checked 2026-11-03.