Skip to main content
v2026.11,858 entries · CC-BY 4.0
LAC HealthMedical & Research SuppliesReagents, PPE & instruments — chain-of-custody documented.Fast, traceable sourcing built for regulated research environments, from bench consumables to instrumentation.Shop lac.us CodeCASRAIlac.us

Stylet for Endotracheal Tube: Types, Sizes and Materials

What an endotracheal tube stylet is, how it is built, how Shiley and Ambu size ranges differ, and how a stylet differs from an airway bougie.

Written and maintained by CASRAI Editorial Board

Last updated

This page describes products and general use; it is not medical advice.

An endotracheal tube stylet is a thin, bendable rod that sits inside an endotracheal tube (ETT) to hold it in a chosen shape. It is used by clinicians who perform intubation, and bought by clinic, emergency and airway-cart staff who need to match the right stylet to the right tube. The main thing to know before ordering: stylet size labels are not universal, so two brands that both say “small” or “size 10” can fit different tube diameters.

What is a stylet for an endotracheal tube?

A stylet is a malleable guide placed inside an endotracheal tube so the tube keeps a curve suited to the airway. It is a single-use accessory in the products described here. It is different from an airway bougie, which is covered below. Who uses it: anesthesia and emergency clinicians, paramedics, and the staff who stock airway kits and carts. This page covers product features and sizing only, not how to place a tube.

How is an intubating stylet built?

The Medtronic Shiley intubating stylet has a malleable aluminum core inside a plastic sheath. The sheath carries a lubricated coating (Satin-Slip), the diameter is consistent along its length, and the product is not made with natural rubber latex or DEHP. The manufacturer says the sheath extends beyond the stylet tip, which it states helps reduce the risk of trauma if the stylet moves beyond the ETT tip (Medtronic product page, checked 2026-10-30).

The Ambu SureSight stylet is built for use with a video laryngoscope. Ambu lists a handle that keeps the stylet from protruding past the distal end of the tube, an atraumatic bent tip, and a stopper on the small size to suit various tube lengths. It is free of PVC, phthalates and natural rubber latex, and is listed as MR unsafe (Ambu product page, checked 2026-10-30).

Types and variants

Type Typical use Key difference
Malleable intubating stylet (example: Medtronic Shiley) General orotracheal intubation aid; fits ETT 2.5 to 10.0 mm ID across the range Sterile, single-use; aluminum core in a lubricated plastic sheath; sizes numbered 6.0, 10 and 14
Video-laryngoscope stylet (example: Ambu SureSight) Orotracheal intubation with the SureSight video laryngoscope, single-lumen tubes Single-use, supplied non-sterile; sizes small, medium, large

Stylet and airway bougie

FDA lists the stylet as its own device type: “Stylet, Tracheal Tube”, product code BSR, regulated under 21 CFR 868.5790 and classified as Class I (openFDA device classification, checked 2026-10-30). An airway bougie is a different tool. It is a separate introducer rather than a rod carried inside the tube, which is why reviews compare the two as alternatives. A 2021 systematic review and meta-analysis of tracheal tube introducers (bougies) and stylets in the prehospital setting (European Journal of Trauma and Emergency Surgery) found both function as efficacious aids. With video technology, bougies showed a statistically significant first-pass advantage (RR 1.15, 95% CI 1.10 to 1.21); without it, the review reported no statistical difference in first-pass or overall success, and stylets were associated with shorter time to intubation. This is a research summary, not guidance for any individual patient.

Sizes and specifications that matter

Figures below are as listed by each manufacturer on 2026-10-30. Note that the same label maps to different tube sizes by brand.

Product Stylet size label Listed ETT inner diameter Other listed detail
Medtronic Shiley 85863 6.0 2.5 to 4.5 mm Length 280 (as listed by manufacturer); 20 per box; sterile
Medtronic Shiley 85864 10 4.0 to 6.0 mm Length 350 (as listed); 20 per box; sterile
Medtronic Shiley 85865 14 Greater than 5.0 mm Length 350 (as listed); 20 per box; sterile
Ambu SureSight Small 2.5 to 4.0 mm Stopper for various tube lengths; non-sterile
Ambu SureSight Medium 4.5 to 5.5 mm Non-sterile
Ambu SureSight Large 6.0 mm or larger Non-sterile

How to choose

Only criteria the manufacturers themselves state are listed here.

  • Tube-size range. Check the manufacturer’s listed ETT inner-diameter range for each stylet size. Both manufacturers publish one, and they differ.
  • Sterility. Shiley stylets are listed as sterile; the Ambu SureSight stylet is listed as non-sterile. Confirm what your protocol requires.
  • Laryngoscope compatibility. The Ambu stylet is made for the SureSight video laryngoscope. See the guides on the laryngoscope and video laryngoscope for the instrument side.
  • Materials. Both are listed free of natural rubber latex; Shiley is also listed DEHP-free and Ambu PVC- and phthalate-free.

Safe use and handling basics

  • Both products are single-use; do not reuse them.
  • Both manufacturers design against the stylet tip extending past the end of the tube (sheath extension on the Shiley, handle on the Ambu).
  • Follow the manufacturer’s instructions for use for the exact product, and your facility’s protocols.
  • The Ambu stylet is listed as MR unsafe.

Tube sizing for the tube itself is covered in the endotracheal tube guide; blade sizes are in Macintosh blade sizes.

Common mistakes

  • Assuming a size label is the same across brands. Shiley size 10 is listed for 4.0 to 6.0 mm tubes; Ambu medium is listed for 4.5 to 5.5 mm.
  • Stocking a video-laryngoscope-specific stylet for a standard laryngoscope setup, or the reverse, without checking compatibility.
  • Confusing a stylet with an airway bougie when writing a requisition.

Supplies for emergency airway and trauma response are listed under emergency and trauma supplies.

FAQ

What is the difference between an ETT stylet and an airway bougie?

A stylet is a malleable rod placed inside the endotracheal tube. A bougie is a separate introducer. A 2021 prehospital meta-analysis found both effective, with a first-pass advantage for bougies only where video technology was used.

Is an endotracheal tube stylet a regulated device?

Yes. FDA classifies “Stylet, Tracheal Tube” (product code BSR) as Class I under 21 CFR 868.5790 (openFDA, checked 2026-10-30).

Are stylet sizes the same between manufacturers?

No. See the sizing table: the same label maps to different tube inner-diameter ranges depending on the brand.

Are intubating stylets sterile?

It depends on the product. The Shiley stylet is listed as sterile and the Ambu SureSight stylet as non-sterile, both single-use.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Stylet for Endotracheal Tube: Types, Sizes and Materials

Ask your first 2 questions free below. Subscribers get 150 a day for $29 a month.

An AI assistant specialized in research administration. It cites the sources behind every answer, labels web answers and says when it can't answer.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays free to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo