Written and maintained by CASRAI Editorial Board
Published
On this page
Tricine (N-[tris(hydroxymethyl)methyl]glycine, CAS 5704-04-1) is a zwitterionic organic biological buffer with an effective buffering range of pH 7.4 to 8.8 and a pKa of 8.05 at 25 °C. Originally synthesized as one of Good’s buffers to overcome the physiological limitations of phosphate and carbonate systems, Tricine is widely utilized across molecular biology, biochemistry, and analytical laboratories. Its most prominent laboratory application is serving as the trailing ion in Tricine-SDS-PAGE (polyacrylamide gel electrophoresis), where its lower electrophoretic mobility at alkaline pH allows high-resolution separation of low-molecular-weight proteins and peptides ranging from 1 to 100 kDa without requiring high acrylamide concentrations or concentrated urea.
Beyond discontinuous gel electrophoresis, Tricine provides an inert buffering environment for chloroplast thylakoid photophosphorylation assays, bioluminescent firefly luciferase reaction systems, and cell culture formulations sensitive to trace metal fluctuations. Because it chelates calcium and magnesium ions only negligibly, it preserves the activity of divalent-cation-dependent enzymes while maintaining precise physiological pH control.
Definition, chemical structure and core properties
Tricine was introduced in 1966 by Norman E. Good and colleagues in their foundational paper on Good’s biological buffers. Good sought synthetic buffering compounds that matched living cellular environments without participating in enzymatic side reactions. The compound was synthesized by condensing tris(hydroxymethyl)aminomethane (Tris) with chloroacetic acid, yielding a substituted amino acid derivative whose trivial name represents a portmanteau of its parent structures: tris and glycine.
Chemically, Tricine has the IUPAC systematic name 2-{[1,3-dihydroxy-2-(hydroxymethyl)propan-2-yl]amino}acetic acid, an empirical molecular formula of C6H13NO5, and a molecular weight of 179.17 g/mol. At standard laboratory conditions, pure Tricine is a white crystalline powder soluble in water up to 1 M (approximately 179.2 g/L) at 20 °C, producing clear, colorless solutions. In aqueous solution, Tricine behaves as a zwitterion: the tertiary amine group has a pKa of 8.05 at 25 °C (8.15 at 20 °C), while its terminal carboxyl group has a pKa below 2.5. Throughout the physiological pH range (pH 7.4 to 8.8), the carboxyl group carries a negative charge while the amino group is partially protonated, ensuring high aqueous solubility and low partition into biological membranes.
A central advantage of Tricine in biological research is its optical neutrality. Unlike aromatic buffers, high-purity Tricine solutions exhibit negligible ultraviolet absorption at wavelengths of 260 nm and 280 nm (A260 < 0.04 and A280 < 0.02 for a 1 M aqueous solution). This property allows researchers to conduct spectrophotometric nucleic acid measurements, Bradford and bicinchoninic acid (BCA) protein determinations, and optical enzyme kinetics directly in buffered media without baseline skewing or background subtraction errors.
Tricine also exhibits minimal coordination affinity toward biologically essential divalent cations. While phosphate buffers precipitate insoluble calcium and magnesium complexes at alkaline pH, Tricine forms only weak coordination complexes with divalent copper (log K approximately 5.7) and has negligible binding constants for Ca2+, Mg2+, and Mn2+. This makes it a preferred medium for studying ATP-dependent kinases, photosynthetic phosphorylation, and membrane transport systems where divalent cations are required cofactors.
The dissociation constant of Tricine displays a temperature dependence characterized by a temperature coefficient (dpKa/dT) of -0.021 pH units per degree Celsius. As ambient temperature increases, the pKa decreases predictably. A buffer adjusted to pH 8.05 at 25 °C shifts to approximately pH 8.15 when operated in a cold room at 4 °C, and drops to pH 7.84 at 37 °C. Precise protocols mandate that pH adjustments be verified at the exact intended operating temperature of the assay.
How Tricine-SDS-PAGE works: the electrophoretic mechanism
The widespread adoption of Tricine in proteomics stems from the discontinuous electrophoresis methodology developed by Hermann Schägger and Gebhard von Jagow in 1987, and refined by Schägger in 2006. In standard SDS-PAGE protein electrophoresis based on the traditional Laemmli system, glycine acts as the trailing zwitterion. While the Laemmli system resolves proteins larger than 30 kDa with excellent sharpness, it fails to separate low-molecular-weight proteins and short peptides (1 to 20 kDa). Peptides within this range migrate close to the leading edge of the ion front, where they co-migrate with excess sodium dodecyl sulfate (SDS) micelles and the tracking dye, resulting in smeared, unresolved bands.
The physical cause of this limitation lies in the ionization properties of glycine compared to the Kohlrausch regulating function. Glycine possesses a high pKa of 9.60. In the Laemmli stacking gel at pH 6.8, glycine is weakly dissociated and carries very little net negative charge, causing it to lag behind protein-SDS complexes and compress them into a tight starting band between chloride ions and glycine. However, once the proteins enter the Laemmli resolving gel at pH 8.8, glycine ionizes significantly, accelerating rapidly down the gel. Because small peptides have high electrophoretic mobility due to their small Stokes radii, their migration velocity approaches that of the unhindered glycine front. Consequently, small peptides cannot de-stack properly from the trailing ion boundary.
Schägger replaced glycine with Tricine in the cathode running buffer to alter trailing ion mobility. Because Tricine has a lower pKa of 8.05, its degree of ionization at the resolving gel operating pH (pH 8.45 in the Schägger system) is substantially higher than that of glycine. However, Tricine possesses a molecular mass more than double that of glycine (179.17 g/mol versus 75.07 g/mol) and a bulkier tri-hydroxy spatial conformation. This higher molecular drag lowers its electrophoretic mobility. As a result, the Tricine trailing ion moves considerably slower through the polyacrylamide sieving matrix than glycine does at the same pH.
This controlled retardation of the trailing ion expands the operational separation window between the fast-moving leading chloride ions and the trailing Tricine front. Small peptides and low-molecular-weight proteins migrate freely behind the chloride front but ahead of the retarded Tricine boundary, separating strictly according to their mass-to-charge ratios within the sieving matrix. Peptides between 1 and 20 kDa achieve baseline chromatographic separation, and band resolution remains distinct down to single-kilodalton fragments without requiring high gel percentages that cause gel brittleness and poor electroblotting transfer.
The complete Schägger system utilizes a multi-phase gel architecture consisting of a 4% total monomer (T) stacking gel, an optional 10% T spacer gel, and a 16.5% T resolving gel. The spacer gel decelerates the leading ion boundary slightly before peptides enter the dense sieving matrix, sharpening peptide zones and eliminating edge distortion. The data table below compares the physical and chemical constants of Tricine with other major biological buffers used across analytical workflows.
Standard laboratory preparation protocols and recipes
Preparing solutions for Tricine-SDS-PAGE requires strict adherence to stoichiometric ratios and specific pH adjustment instructions. Unlike conventional Tris-HCl buffer systems, the upper cathode buffer must never be titrated with strong acid or base. The following formulations follow the standardized Schägger protocols and verified commercial technical standards.
Schägger discontinuous stock solutions
Three concentrated stock buffers form the backbone of the Schägger Tricine electrophoresis method:
- 3x Gel Buffer (3.0 M Tris-HCl, 0.3% SDS, pH 8.45): Dissolve 181.65 g of Tris base in ~300 mL deionized water. Add concentrated HCl (~30 mL) with stirring until pH reaches 8.45 at 20 °C. Add 1.5 g electrophoresis-grade SDS, dilute to 500 mL, filter through 0.45 μm, and store at 18 to 25 °C.
- 10x Anode Buffer (Lower Tank, 1.0 M Tris-HCl, pH 8.9): Dissolve 121.14 g Tris base in 800 mL deionized water. Adjust pH to 8.90 at 20 °C with concentrated HCl (~15 to 20 mL). Dilute to 1,000 mL. Dilute 1:10 with water for 1x working buffer (100 mM Tris-HCl, pH 8.9).
- 10x Cathode Buffer (Upper Tank, 1.0 M Tris, 1.0 M Tricine, 1.0% SDS): Dissolve 121.14 g Tris base, 179.17 g analytical-grade Tricine, and 10.0 g SDS in 800 mL deionized water with gentle warming. Bring volume to 1,000 mL. Do not adjust pH with acid or base; equilibrium pH is ~8.25 at 20 °C. Dilute 1:10 for 1x working cathode buffer (100 mM Tris, 100 mM Tricine, 0.1% SDS).
Acrylamide stock mixtures (AB-3 and AB-6)
Tricine gel pore architecture is governed by the crosslinker percentage (%C), defined as bisacrylamide relative to total monomer:
- AB-3 Stock Solution (49.5% T, 3% C): Dissolve 48.0 g acrylamide and 1.5 g N,N’-methylenebisacrylamide in water to 100 mL. Optimized for proteins from 5 to 100 kDa.
- AB-6 Stock Solution (49.5% T, 6% C): Dissolve 46.5 g acrylamide and 3.0 g bisacrylamide in water to 100 mL. Doubled crosslinker creates narrower pores for small peptides between 1 and 5 kDa.
Tricine sample loading buffer formulation
Loading peptides into a Tricine gel requires a specialized sample buffer. Traditional Laemmli sample buffer containing bromophenol blue is suboptimal because bromophenol blue co-migrates directly over peptide bands between 1 and 3 kDa. The Bio-Rad formulation (Catalog #1610739) utilizes Coomassie Brilliant Blue G-250:
- 200 mM Tris-HCl (pH 6.8)
- 40% (v/v) Glycerol (provides density for clean well loading)
- 2.0% (w/v) SDS (ensures uniform charge-to-mass ratio)
- 0.04% (w/v) Coomassie Brilliant Blue G-250 (tracking dye)
Prior to loading, reducing agent is added: 20 μL β-mercaptoethanol (or 50 mM DTT) per 950 μL 2x buffer. Samples are mixed 1:1 with 2x buffer and denatured at 85 °C for 2 minutes, or 70 °C for 10 minutes. Avoid heating peptide samples at 100 °C, which promotes thermal cleavage of acid-labile Asp-Pro bonds.
Where Tricine matters in research, biotechnology and lab operations
Tricine fulfills critical roles across diverse biochemical disciplines where standard amine or phosphate buffers interfere with experimental outcomes. Understanding these operational domains helps research facilities standardize reagent inventories.
Membrane protein complexes and blue native PAGE
Hydrophobic membrane proteins, such as mitochondrial respiratory chain complexes, photosynthetic reaction centers, and bacterial transport channels, present severe aggregation challenges. In Blue Native PAGE (BN-PAGE) and high-resolution clear native electrophoresis, Tricine serves as the cathode buffer to separate multiprotein complexes ranging from 10 kDa to 10 MDa in active states. Combined with mild detergents like digitonin or dodecylmaltoside, Tricine preserves quaternary associations while Coomassie dye imparts negative charge without denaturation.
Proteomic peptide mapping and mass spectrometry
In bottom-up proteomics and enzymatic digestion quality control (such as trypsin digests of therapeutic antibodies), confirming digestion completeness requires resolving peptide fragments under 10 kDa. Tricine-SDS-PAGE enables bench scientists to visually verify cleavage profiles prior to LC-MS/MS runs, preventing costly mass spectrometry instrument time from being wasted on undigested precursors.
Bioluminescence and enzymatic ATP assays
Firefly luciferase catalyzes the ATP-dependent oxidation of luciferin, generating light proportional to ATP concentration. Phosphate buffers strongly inhibit firefly luciferase through competitive anion binding at the nucleotide-binding pocket. Tricine is the industry-standard buffer for firefly luciferase assays (typically 25 mM, pH 7.8), providing robust buffering without inhibiting quantum yield, enabling high-sensitivity ATP quantitation down to picomolar thresholds in cell viability screening.
Reagent procurement and laboratory grade selection
When procuring raw Tricine powder, laboratories should match purity to analytical application. Crude chemical grades often contain heavy metal contaminants and residual synthesis precursors that inhibit enzymes or induce background fluorescence. For electrophoretic and cell culture work, laboratories should specify BioPerformance Certified or Biotechnology Grade material with assay purity >=99.0%, heavy metal content <=5 ppm, and endotoxin levels <0.1 EU/mg.
Downstream transfer and Western blot considerations
Resolving small proteins on a Tricine gel is only the first step in immunological or structural characterization. Downstream electroblotting requires modified parameters compared to standard blotting workflows.
When transferring peptides from a Tricine gel to a membrane using a Western blot transfer buffer, pore size is paramount. Standard 0.45 μm PVDF or nitrocellulose membranes permit small peptides (<15 kDa) to blow through during transfer. Laboratories must use 0.2 μm or 0.1 μm pore-size membranes. Transfer duration should be limited to 30 to 45 minutes at 100 V (or 25 V for 60 minutes in semi-dry units) to prevent over-transfer.
When transferred peptides are intended for N-terminal Edman degradation microsequencing, standard glycine transfer buffers (25 mM Tris, 192 mM glycine, 20% methanol) must be avoided. Residual glycine absorbed onto the PVDF membrane elutes during sequencing cycles, producing an enormous glycine peak on the phenylthiohydantoin (PTH) HPLC chromatogram that masks early cycles. Researchers running Tricine gels for Edman sequencing must transfer in 10 mM CAPS buffer at pH 11.0 with 10% methanol, or 0.5x TBE buffer, completely eliminating glycine contamination.
Common bench mistakes and troubleshooting
Achieving reproducible results with Tricine systems requires avoiding several common operational pitfalls:
- Titrating the Cathode Buffer: The most frequent bench error is measuring the pH of the 10x Cathode buffer stock and attempting to titrate it to pH 8.45 using HCl or NaOH. The 10x Cathode buffer relies on equimolar Tris base and Tricine equilibrium (~pH 8.25). Adding strong acid or base alters counter-ion balance, destroying the Kohlrausch moving boundary and causing erratic peptide migration. Never titrate the Cathode buffer.
- Buffer Cross-Contamination or Single-Buffer Mismatch: In vertical gel units with separate upper and lower reservoirs, accidentally pouring standard Tris-glycine running buffer into the cathode chamber eliminates the Tricine mobility gradient. The gel will run as a degraded Laemmli gel with unresolved peptide smears. Ensure the upper chamber contains Tris-Tricine-SDS buffer and the lower chamber contains Tris-HCl anode buffer.
- Excess Salt in Sample Lysates: High ionic strength in cell lysis buffers (e.g., NaCl above 150 mM or high detergent concentrations) creates localized conductivity spikes in sample wells. This distorts the electrical field, leading to severe band smiling and peptide compression. Desalt samples by gel filtration spin columns or dilute them with deionized water prior to adding sample buffer.
- Excessive Sample Heating: Boiling peptides at 100 °C for 5 to 10 minutes can induce peptide bond fragmentation and deamidation, generating artificial multiple bands. Heat peptide samples at 85 °C for 2 minutes or 70 °C for 10 minutes to denature structures without chemical degradation.
- Temperature Elevation During Gel Electrophoresis: Because Tricine has a significant temperature coefficient (-0.021 pH/°C), excessive resistive heating during high-voltage runs lowers operational buffer pH and alters mobility. Maintain running voltage at 100 to 125 V constant and run mini-gels in an ice-water bath or cold room if chamber temperature exceeds 25 °C.
Frequently asked questions
What is the difference between Tricine and glycine in SDS-PAGE?
Tricine and glycine both function as trailing zwitterions in discontinuous SDS-PAGE, but differ in molecular weight and pKa. Glycine (MW 75.07 g/mol, pKa 9.60) accelerates rapidly in resolving gels and co-migrates with small peptides under 20 kDa. Tricine (MW 179.17 g/mol, pKa 8.05) has lower mobility at gel operating pH (8.45) due to steric molecular drag, creating a wider separation zone that resolves peptides between 1 and 100 kDa.
Why should you not adjust the pH of Tricine cathode running buffer?
The Schägger 10x cathode buffer (1.0 M Tris base, 1.0 M Tricine, 1.0% SDS) relies on self-buffering equilibrium between equal molar concentrations of Tris base and Tricine zwitterion, stabilizing naturally around pH 8.25. Titrating with HCl introduces excess chloride that disrupts the leading-ion boundary, while titrating with NaOH introduces excess sodium that increases conductivity and causes resistive overheating.
What molecular weight range does Tricine-SDS-PAGE resolve best?
Tricine-SDS-PAGE is optimized for resolving proteins and peptides in the 1 to 100 kDa range, providing superior resolution for low-molecular-weight targets between 1 and 20 kDa. Adjusting the acrylamide crosslinking ratio from 3% C (AB-3) to 6% C (AB-6) and incorporating 6 M urea into the resolving matrix achieves baseline separation for peptides down to 1 kDa.
Why is Coomassie G-250 preferred over bromophenol blue in Tricine sample buffer?
In traditional Laemmli SDS-PAGE, bromophenol blue migrates at the dye front ahead of intact proteins. In the Tricine system, bromophenol blue has an electrophoretic mobility that directly overlaps peptides between 1 and 3 kDa, masking visualization. Coomassie Brilliant Blue G-250 has lower mobility, allowing clean visualization of the migration boundary without obscuring peptide bands.
How does temperature affect the buffering capacity of Tricine?
Tricine has a temperature coefficient (dpKa/dT) of -0.021 pH units per degree Celsius. As temperature increases, its pKa drops, shifting effective buffering. A Tricine solution adjusted to pH 8.05 at 25 °C shifts to pH 8.15 at 4 °C and drops to pH 7.84 at 37 °C. Experimental buffers must be adjusted and calibrated at the exact working temperature of the intended assay.
Sources
- Good, N. E., Winget, G. D., Winter, W., Connolly, T. N., Izawa, S., & Singh, R. M. (1966). Hydrogen ion buffers for biological research. Biochemistry, 5(2), 467–477. https://pubs.acs.org/doi/10.1021/bi00866a011 (Checked 2026-11-14)
- Schägger, H., & von Jagow, G. (1987). Tricine-sodium dodecyl sulfate-polyacrylamide gel electrophoresis for the separation of proteins in the range from 1 to 100 kDa. Analytical Biochemistry, 166(2), 368–379. https://doi.org/10.1016/0003-2697(87)90587-2 (Checked 2026-11-14)
- Schägger, H. (2006). Tricine-SDS-PAGE. Nature Protocols, 1(1), 16–22. https://www.nature.com/articles/nprot.2006.4 (Checked 2026-11-14)
- National Center for Biotechnology Information (NCBI). PubChem Compound Summary for CID 79784: Tricine. https://pubchem.ncbi.nlm.nih.gov/compound/Tricine (Checked 2026-11-14)
- Bio-Rad Laboratories. Instruction Manual: Tricine Sample Buffer (#1610739) & Tris/Tricine/SDS Running Buffer 10x (#1610744). https://www.bio-rad.com/en-us/sku/1610739-tricine-sample-buffer-for-protein-gels-30-ml (Checked 2026-11-14)
- Sigma-Aldrich / Merck KGaA. Specification Sheet: Tricine BioPerformance Certified (T0377). https://www.sigmaaldrich.com/US/en/product/sigma/t0377 (Checked 2026-11-14)
- Thermo Fisher Scientific. Technical Protocol: Novex Tricine SDS Running Buffer (10X) and Tricine Gel System (MAN0000806). https://www.thermofisher.com/order/catalog/product/LC1675 (Checked 2026-11-14)
Data: Physicochemical Properties and Operational Constants of Good's Biological Buffers in Physiological and Alkaline Ranges
Original comparative compilation of physicochemical parameters, dissociation constants, and operational characteristics for Tricine and related zwitterionic biological buffers across physiological and alkaline ranges, compiled from Good et al. (1966), PubChem chemical records, and Sigma-Aldrich technical specifications.
Period covered: 1966/2026.
| Buffer Compound | CAS Number | Molecular Weight (g/mol) | pKa at 25 C | dpKa/dT (pH/C) | Useful pH Range | Primary Laboratory Application |
|---|---|---|---|---|---|---|
| Tricine | 5704-04-1 | 179.17 | 8.05 | -0.021 | 7.4–8.8 | Peptide SDS-PAGE, chloroplast photophosphorylation, luciferase assays |
| Bicine | 150-25-4 | 163.17 | 8.26 | -0.018 | 7.6–9.0 | Low-temperature enzyme kinetics, protein crystallization, serum assays |
| HEPES | 7365-45-9 | 238.3 | 7.48 | -0.014 | 6.8–8.2 | Cell culture media, organ perfusion, live-cell confocal imaging |
| TAPS | 29915-38-6 | 243.28 | 8.4 | -0.018 | 7.7–9.1 | Capillary zone electrophoresis, DNA sequencing gels, alkaline phosphatase |
| TES | 7365-44-8 | 229.25 | 7.4 | -0.02 | 6.8–8.2 | Viral transport media, succinate oxidation assays, cell washing |
| Tris | 77-86-1 | 121.14 | 8.06 | -0.028 | 7.0–9.0 | Standard TAE/TBE nucleic acid electrophoresis, Western blot transfer |
| MOPS | 1132-61-2 | 209.26 | 7.14 | -0.015 | 6.5–7.9 | Formaldehyde agarose RNA gels, bacterial culture media, cell lysis |
| Glycine | 56-40-6 | 75.07 | 9.6 | -0.025 | 8.6–10.6 | Laemmli SDS-PAGE trailing ion, Western blot transfer buffer |
Sources
- Good et al. (1966) Hydrogen ion buffers for biological research (accessed 2026-11-14)
- PubChem Compound Database (NCBI) (accessed 2026-11-14)
- Sigma-Aldrich Biological Buffers Guide (accessed 2026-11-14)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.