Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
Not medical advice. This page summarises the manufacturer’s general directions for use for a Voldyne 4000 volumetric exerciser. It does not tell you what volume to aim for, how often to use it or whether you need one. Those choices belong to your physician or therapist.
Short answer: the Voldyne 4000 is used by attaching the tubing and mouthpiece, sliding the green pointer to the volume your clinician prescribed, breathing out normally, sealing your lips around the mouthpiece, and breathing in slowly so the piston rises while the green flow chip stays inside the smiley-face flow range. Then you remove the mouthpiece, hold the breath as directed, breathe out, rest and repeat. This is a plain-language reading of the manufacturer’s directions for use (Hudson RCI / Teleflex, checked 1 November 2026). The device is a type of incentive spirometer; if your device is a different brand, see the sibling guide on the AirLife spirometer instead of assuming the steps match.
What you need
The directions for use describe the device as an inspiratory deep-breathing positive exerciser for adult and paediatric patients above 5 years, and as a single-patient, multi-use device for hospital or home-care settings. The parts the steps refer to are:
- The exerciser body with its chamber and piston. The top of the piston shows the volume you have breathed in.
- The green pointer (goal marker), which you slide to the prescribed volume level.
- The green flow chip and the smiley-face flow range, which show whether your breath is within the intended flow.
- The expandable tubing and mouthpiece, supplied in the package. The Medline brochure (ML1318, April 2024) also lists a built-in handle, a mouthpiece holder and calibrations labelled on both sides.
Steps
These steps follow the manufacturer’s numbered sheet. Frequency of use and the recommended inspiratory volumes are set by a physician or therapist, not by the device.
- Set up. Take the components out of the package, expand the tubing to its full length and attach its open end to the stem on the front of the exerciser. Slide the green pointer to the prescribed volume level.
- Position and breathe out. Hold the exerciser, or stand it, upright. Breathe out normally, then place your lips tightly around the mouthpiece.
- Breathe in slowly. Inhale slowly to raise the piston. While inhaling, keep the green flow chip in line with the smiley-face flow range. Keep inhaling and try to raise the piston to the prescribed volume level. The top of the piston shows the volume inspired.
- Finish. When the inhalation is complete, remove the mouthpiece, hold your breath as prescribed and breathe out normally. Let the piston return to the bottom of the chamber.
- Rest and repeat as directed by your clinician.
What can go wrong
- The flow chip leaves the smiley-face range. The directions tell you to keep the chip in line with the flow range while inhaling. They do not give further troubleshooting, so if you cannot do this, ask your clinician or therapist rather than guessing.
- Residue or soil in the mouthpiece or tubing. The cleaning routine below ends with a visual check, and the sheet carries a caution to inspect the corrugated tubing after cleaning to ensure it is clean.
- Sharing the device. It is labelled single patient, multi-use. It is not meant to be passed between people.
- Setting your own goal. The sheet includes a predictive inspiratory-capacity nomogram by sex, age and height, with values rounded to the nearest 50 mL and attributed to Polgar and Promadhat (American Review of Respiratory Disease, September 1979). The prescribed level is still the clinician’s decision, so do not self-set it from the chart.
How to clean the mouthpiece
The directions for use give this cleaning routine for the mouthpiece:
- Remove the mouthpiece from the expandable tubing.
- Dilute 1 mL of liquid Dawn dishwashing detergent in 1 L of warm tap water in a clean tub.
- Immerse the mouthpiece and soak for about 5 minutes.
- While it is still immersed, wipe the inside and outside with a non-linting wipe for at least 30 seconds.
- Rinse under warm running tap water for at least 1 minute, or until the soap is gone.
- Dry with non-linting wipes, inspect it, and repeat if soil remains.
- Reconnect it to the tubing, then visually check that the corrugated tubing is clean.
When to get professional help
Ask your physician, nurse or respiratory therapist about the prescribed volume level, how often to use the device, how long to hold each breath, and any symptoms you notice while using it. The manufacturer states that frequency of use and recommended inspiratory volumes are at the direction of a physician or therapist. If you feel unwell, seek medical care instead of continuing the exercise.
Voldyne 2500, 4000 and 5000: model differences
Voldyne 2500 and how to use a Voldyne 2500
The Medline brochure lists the Voldyne volumetric exerciser in two models, the 4000 (item 4719016CE) and the 2500 (item 4719018CE), for adult and paediatric patients. It does not publish a separate step list for the 2500, so this page does not claim its steps are identical. Use the directions packed with your device.
Voldyne 5000 and how to use a Voldyne 5000
This page covers the 4000 only; follow the instructions supplied with a 5000.
How the device is regulated
In the United States, 21 CFR 868.5690 defines an incentive spirometer as a device that indicates a patient’s breathing volume or flow and provides an incentive to improve ventilation; it is classified Class II (performance standards). The Medline brochure describes the Voldyne exercisers as class Im non-sterile medical devices under the EU system, intended for use under the supervision of healthcare professionals. For a related device that measures flow rather than volume, see what a peak flow meter is, and for mouthpiece hygiene on spirometers in general see the spirometer mouthpiece guide.
FAQ
How do I use a Voldyne 4000?
Attach the expanded tubing and mouthpiece, set the green pointer to the prescribed volume, breathe out, seal your lips around the mouthpiece, inhale slowly keeping the green flow chip in the smiley-face range, then remove the mouthpiece, hold the breath as directed, exhale and rest. See the numbered steps above.
What do the green pointer and the green flow chip do?
The green pointer marks the prescribed volume level you aim for. The green flow chip shows your inhalation flow and should stay in line with the smiley-face flow range while you breathe in.
Where do I read how much I breathed in?
At the top of the piston, which the manufacturer says indicates the inspired volume.
How often should I use it, and what volume should I aim for?
That is set by a physician or therapist. The device sheet leaves frequency and volume to the clinician.
Are the instructions the same for a Voldyne 2500 or 5000?
The manufacturer’s step list is for the 4000 only. Follow the directions supplied with your model.
Can more than one person use the same Voldyne?
No. The manufacturer describes it as a single-patient, multi-use device.
Sources
All three sources were checked on 1 November 2026.
- Hudson RCI / Teleflex, Directions for use: VOLDYNE 4000 Volumetric Exerciser (manufacturer sheet, retailer-hosted copy): https://rehabmart.com/pdfs/voldyne_incentive_spirometer_medline_4000_ml_user_manual.pdf
- Medline, Voldyne Volumetric Exerciser brochure, ML1318_EN, April 2024: https://assets.medline.eu/Docs/Products/BRO_Voldyne_Volumetric_Exercise_Flyer_ML1318_EN_April_2024.pdf
- Legal Information Institute, 21 CFR 868.5690 Incentive spirometer: https://www.law.cornell.edu/cfr/text/21/868.5690