Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
General product and regulatory information only. This page is not medical advice and does not describe how to use an instrument on a patient.
Short answer
A Weitlaner retractor is a hand-held, self-retaining surgical retractor: two arms with prongs and a ratchet that holds the opening once it is set. Listings describe it by overall length, prong count per arm (for example 3×4) and whether the prongs are sharp or blunt. In the United States the same-looking instrument can sit under different FDA product codes and classes depending on its intended use.
Definition and scope
The ICRC/IFRC Standard Products Catalogue describes its Weitlaner item as a self-retaining retractor made of martensitic steel with a locking mechanism, two arms (one with 3 prongs and one with 4 prongs), prongs that are sharp or blunt, and an opening set by a ratchet. Its stated use is to retract skin, fatty tissues and muscles, particularly in small orthopaedic, peripheral vascular and hernia surgeries. That catalogue entry is marked as no longer updated (last updated 31 December 2018), so treat it as a description of the pattern rather than a current purchasing record.
For the wider family of retraction instruments, see what a surgical retractor is. Other self-retaining patterns covered on CASRAI include the Gelpi retractor and the Balfour retractor.
How it is described in practice
Product records and supplier listings name the instrument by a short string of attributes. A real regulator-hosted example is the AccessGUDID record for a “Weitlaner Retractor”, model 7242-31, described as “Blunt 19.5cm 3×4 prongs” (labeler KOROS U.S.A.). That record lists FDA product code GAD (Retractor), states that the device is not packaged sterile and requires sterilization (moist heat/steam), states that it is not single-use, and notes that the labeling does not contain MRI safety information.
The sections below do not cover how the instrument is placed or adjusted in a patient; that belongs in manufacturer instructions for use and clinical training.
Variants documented in the ICRC catalogue
| Attribute | What the catalogue states |
|---|---|
| Arms | Two arms: one with 3 prongs, one with 4 prongs |
| Prong tip | Sharp or blunt |
| Length | 13 cm or 16 cm |
| Material | Martensitic steel |
| Opening | Set by a ratchet (self-retaining, locking mechanism) |
| Packaging | Individually packed |
The AccessGUDID example above (19.5 cm, blunt, 3×4 prongs) shows that other lengths exist; the catalogue figures are one organisation’s range, not a complete list of sizes.
Where it matters for labs, clinics and supply decisions
Why FDA lists more than one code for a self-retaining retractor
Regulatory class follows intended use, not the pattern name. Two FDA records show this:
- GAD, Retractor: the FDA classification record places it in the General, Plastic Surgery panel as Class 1 under 21 CFR 878.4800 (manual surgical instruments for general use). 878.4800 defines these as nonpowered, hand-held or hand-manipulated devices, reusable or disposable, intended for various general surgical procedures. Class I devices here are exempt from 510(k) subject to the limitations in 21 CFR 878.9.
- GZT, retractor, self-retaining, for neurosurgery: the FDA product classification lists regulation 882.4800, Class 2, requiring a 510(k), not exempt from GMP, in the Neurology panel.
So a listing that says “self-retaining retractor” can legitimately carry either class. The product code and the stated intended use on the listing, not the shape of the instrument, tell you which applies. For the neurosurgical side of the family, see neurosurgical instruments.
Checklist for reading a listing
| Field | What to look for | Source example |
|---|---|---|
| Length | Overall length in cm | 19.5 cm (GUDID); 13 and 16 cm (ICRC) |
| Prongs | Count per arm, written like 3×4 | GUDID “3×4 prongs” |
| Tip | Sharp or blunt | Both offered (ICRC) |
| Sterility | Supplied sterile or not; sterilization method | Not sterile, moist heat/steam (GUDID) |
| Use | Single use or reusable | Not single-use (GUDID) |
| MRI labeling | Whether MRI safety information is given | None in the GUDID example |
| Product code and regulation | GAD / 878.4800 versus GZT / 882.4800 | FDA classification records |
Replacement blades and attachments are a separate topic; see retractor blades. For the orthopaedic instrument family, see orthopedic surgical instruments.
Common misunderstandings
- “Self-retaining means one FDA class.” It does not. The same descriptive phrase appears under a Class 1 general-use code and a Class 2 neurosurgery code.
- “Not sterile on the label means defective.” The GUDID example is explicitly not packaged sterile and lists steam sterilization as a requirement before use.
- “The length in the name is the opening width.” Listings give the instrument’s overall length; the catalogue states the opening is set by the ratchet.
FAQ
What is a Weitlaner retractor?
A self-retaining, hand-held retractor with two prong-bearing arms and a ratchet lock, described by the ICRC catalogue as used to retract skin, fatty tissues and muscles in small orthopaedic, peripheral vascular and hernia surgeries.
What does “3×4 prongs” mean?
One arm has three prongs and the other four, as in the AccessGUDID record and the ICRC catalogue entry.
Is a Weitlaner retractor FDA-regulated?
Yes, as a medical device. The AccessGUDID example carries product code GAD under 21 CFR 878.4800, a Class I category exempt from 510(k) subject to 21 CFR 878.9. A self-retaining retractor intended for neurosurgery falls under code GZT, regulation 882.4800, Class 2.
Is it reusable?
The AccessGUDID example is marked as not single-use and requiring sterilization before use. Check the manufacturer’s instructions for the specific model.
Sources
- eCFR, 21 CFR 878.4800, Manual surgical instrument for general use: https://www.ecfr.gov/current/title-21/part-878/section-878.4800 (checked 2026-10-30)
- FDA Product Classification, GZT, retractor, self-retaining, for neurosurgery: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfPCD/classification.cfm?ID=GZT (checked 2026-10-30)
- openFDA device classification, product code GAD, Retractor: https://api.fda.gov/device/classification.json?search=product_code:GAD (checked 2026-10-30)
- NIH NLM AccessGUDID, Weitlaner Retractor, model 7242-31: https://accessgudid.nlm.nih.gov/devices/10840199508911 (checked 2026-10-30)
- ICRC/IFRC Standard Products Catalogue, item XSINMEDI2422 (entry last updated 2018-12-31): https://itemscatalogue.redcross.int/health–3/surgical-instruments–24/surgical-instruments–111/retractor-self-retaining-superficial-surgery-sharpblunt-weitlaner–XSINMEDI2422.aspx (checked 2026-10-30)