Written and maintained by CASRAI Editorial Board
Published
On this page
Silver Shield gloves are thin, multi-layer laminate chemical-resistant gloves: a barrier film made by laminating a high-energy polymer (EVOH) with a low-energy polymer (polyethylene), sold under the Silver Shield / 4H name and used where a wide range of hazardous chemicals may be handled. They are a different material family from nitrile, latex or butyl rubber, and university safety offices usually treat them as the glove to reach for when other gloves are not rated for a chemical or a laboratory wants a secondary barrier.
What Silver Shield gloves are
The Honeywell/North product data sheet describes the North Silver Shield / 4H range as “a series of disposable, chemical resistant gloves and accessories” with a “unique five layers design” compacted into only 2.7 mils of thickness. The name is a trademark of North Safety Products. The same data sheet positions the range for chemical, petrochemical and refining industries and for emergency response and hazmat clean-ups.
In laboratories the gloves appear in environmental health and safety guidance under the generic heading of laminate gloves. Cornell’s environmental health and safety guidance lists the laminate type under the name “Norfoil” and notes that it is rated for chemicals considered highly toxic and for chemicals that are easily absorbed through the skin. It names the brands Silver Shield (North Hand Protection), 4H (Safety4) and New Barrier (Ansell Edmont) as examples of the type. UMass Amherst’s EHS glove page also uses the term “Silver Shield/Norfoil gloves” for the same class.
Who uses them: laboratory staff handling highly toxic or skin-absorbed chemicals, emergency responders and hazmat clean-up crews, and industrial workers in chemical and petrochemical settings, as the data sheet and the university guidance above describe.
How Silver Shield gloves are built
According to the data sheet, the material is produced by laminating a high-energy polymer (EVOH) with a low-energy polymer (PE), and each layer acts as a barrier. The sheet lists the construction as polyethylene laminated on EVOH in a compacted five-layer design, 2.7 mils thick, made in the U.S.A. A mil is one thousandth of an inch, so 2.7 mils is 0.0027 in, or about 0.07 mm.
That construction explains two things readers often notice. First, the glove is a film rather than a molded rubber shell, and the data sheet describes the range as disposable. Second, the data sheet attributes the protection to the laminated barrier layers, with each layer acting as a barrier, so the manufacturer’s rating for the specific chemical is the figure to read when judging suitability.
Certification and rating information from the data sheet
- The sheet states that the gloves conform to the CE standards EN 420 and EN 374, citing EN 374-2 and EN 374-3.
- Protection is described as “Chemical and Biohazard”.
- Three chemical examples are given at the highest permeation class shown, Class 6, with a breakthrough of more than 8 hours: sodium hydroxide (50%), sulfuric acid (93%) and trichloroethylene.
- The sheet closes with a declaration that it is the user’s responsibility to do the proper tests for the specific application.
The last point matters in practice: the Class 6 figures are examples for named test chemicals, not a blanket guarantee for every chemical or every mixture. See the guide to glove breakthrough time and permeation data for how to read such figures.
Types and variants in the Silver Shield / 4H range
The range is wider than hand protection alone. The data sheet lists six catalogue items, from hand gloves through sleeves, booties and aprons, each identified by a product code. The data table below the guide sets them out side by side with the sizes and lengths the data sheet states.
- Gloves (SSG): the standard hand protection, listed in size 10 and packed 50 to a case.
- Long gloves (SSG29): a gauntlet version 29 inches long, listed in size 10 only.
- Sleeves (SSS): sleeves with elastics, 19 inches long,.
- Booties (SSB): booties with elastic, one size.
- Bib apron (SSA) and coat apron with sleeves (SSCA): body protection in the same laminate.
Sizes and specifications that matter
Only a few values are stated in the data sheet used for this page, so they are the only ones given here: the glove is listed in size 10, the long glove is 29 inches (about 74 cm) in length, the sleeves are 19 inches (about 48 cm) in length, the film is 2.7 mils thick and standard gloves are packed 50 to a case. Because the sheet lists size 10 for the gloves, readers who need a different hand size should read the current manufacturer catalogue for the sizes on offer today, since the sheet used here is an older revision (Eng-Rev-00, 10 August 2007).
How to choose: criteria stated in the sources
Safety guidance from the sources above gives a short set of selection and fit criteria that apply to laminate gloves:
| Source | What it says about laminate / Silver Shield gloves |
|---|---|
| Honeywell/North data sheet | Five-layer EVOH and polyethylene laminate, 2.7 mils thick, conforming to EN 420 and EN 374; the user must test for the specific application. |
| Cornell EHS | Rated for chemicals considered highly toxic and chemicals easily absorbed through the skin; not recommended for use with chloroform. |
| Cornell EHS | The laminate glove can be worn under an outer glove so that the outer glove keeps dexterity and the laminate acts as a secondary barrier if the chemical degrades or permeates the outer glove. |
| UMass Amherst EHS | With Silver Shield/Norfoil gloves it may be possible to wear a tight-fitting glove over the loose glove to increase dexterity and provide optimal chemical protection; thicker gloves can limit dexterity and tactility. |
| Syracuse University EHSS | Publishes a manufacturer chemical resistance guide that compares Silver Shield with butyl, nitrile, natural rubber, Viton and Chemsoft gloves using rating letters, breakthrough times and permeation rates. |
From these sources the practical decision points are: whether the chemical is highly toxic or easily absorbed through the skin (the case where laminate is called out), whether the chemical appears on the manufacturer’s resistance chart for this glove, whether chloroform is involved (where Cornell advises against it), and whether the task needs dexterity that a loose laminate glove cannot give on its own. For the wider decision across glove materials, use the chemical-resistant glove selection guide and the glove compatibility chart definition.
Safe use and handling basics
Wearing laminate gloves with an outer glove
The two university sources agree on the main practical point. Laminate film is loose-fitting and limits dexterity, so the gloves are commonly worn as a liner beneath a tight-fitting outer glove (UMass Amherst) or as an inner layer that serves as a secondary barrier if the chemical gets through the outer glove (Cornell). The outer glove restores grip and feel; the laminate underneath carries the chemical protection.
UMass advises removing and replacing the outer glove immediately if there are any signs of contamination. Cornell’s guidance for double gloving is that if the inner glove is contaminated, both pairs are removed.
Inspection and replacement
- Inspect gloves for holes, cracks and contamination before each use, and discard any that are questionable (Cornell EHS).
- Check for rips, punctures, prior contamination and signs of degradation such as a change in colour or texture, both before and after each use, and replace compromised gloves (UMass Amherst EHS).
- Check the expiry date of disposable gloves and do not use expired ones (UMass Amherst EHS).
Match the glove to the chemical and the task
The data sheet’s declaration that the user must test for the specific application is the safest default. Treat a laminate glove’s rating as chemical-specific: look up the glove and the chemical on a current manufacturer or EHS resistance chart before work starts, and follow the safety data sheet and your institution’s chemical hygiene plan. See PPE selection for chemical handling in the lab for how glove choice fits into the wider PPE decision.
Silver Shield gloves compared with other glove materials
Laminate is one of several glove families a laboratory may stock. The Syracuse University EHSS copy of the North Silver Shield chemical resistance guide places Silver Shield beside butyl, nitrile, natural rubber, Viton and Chemsoft gloves in a single rating table, so a reader can compare them chemical by chemical on the manufacturer’s own ratings. For the rubber and polymer alternatives, see CASRAI’s pages on butyl gloves and on nitrile gloves and chemical resistance.
The sources frame laminate gloves by role rather than as a simple ranking: Cornell calls them out for highly toxic and skin-absorbed chemicals and as a secondary barrier under an outer glove. No single glove material is rated against every chemical, which is why the resistance chart and the data sheet’s user-test declaration are central.
Common mistakes
- Treating the data sheet’s Class 6 examples as universal. The sodium hydroxide, sulfuric acid and trichloroethylene figures apply to those chemicals as tested, not to chloroform or to untested mixtures. Cornell explicitly says laminate gloves are not recommended for chloroform.
- Wearing the loose laminate glove alone for fine work. Both university sources describe the dexterity limit and the outer-glove solution.
- Continuing to work after the outer glove is contaminated. UMass says to remove and replace the outer glove immediately; Cornell says to remove both pairs if the inner glove is contaminated.
- Skipping inspection. Cornell calls for inspection before each use and UMass for checks before and after each use, covering holes, cracks, contamination and degradation.
- Assuming an older data sheet reflects today’s catalogue. The data sheet used here is a 2007 revision; confirm the current product, sizes and certification with the supplier’s present documentation.
- Confusing brand names. Silver Shield, 4H and New Barrier are separate branded products of the laminate type, as Cornell lists them; do not assume equivalence without reading each maker’s documentation.
Sources
- Honeywell/North, “Silver Shield / 4H Series of Gloves and Accessories” product data sheet (Eng-Rev-00, 10 August 2007): https://harmonycr.com/content/PDF/DATA-SHEET/Honeywell-sps-ppe-Silver-Shield-Data-Sheet.pdf (checked 2026-11-14)
- Syracuse University EHSS, Chemical Resistance Guide North Silver Shield: https://ehss.syr.edu/wp-content/uploads/2020/12/Chemical-Resistance-Guide-North-Silver-Shield.pdf (checked 2026-11-14)
- UMass Amherst Environmental Health and Safety, gloves guidance: https://www.umass.edu/ehs/gloves (checked 2026-11-14)
- Cornell University Environmental Health and Safety, glove selection guidance: https://ehs.cornell.edu/book/export/html/1027 (checked 2026-11-14)
Data: Silver Shield / 4H catalogue items: product code, form and stated size or length
Compiled from the Honeywell/North Silver Shield / 4H product data sheet (Eng-Rev-00, 10 August 2007). Lists each catalogue item with its product code, what it covers and the size, length or pack quantity the data sheet states. Cells marked 'not stated' mean the data sheet gives no value.
Period covered: 2007.
| Product | Product code | Form | Stated size or length | Packing |
|---|---|---|---|---|
| Gloves | SSG | Hand glove | Size 10 | Case of 50 |
| Long gloves | SSG29 | Gauntlet glove, 29 in long | Size 10 only | Not stated |
| Sleeves | SSS | Sleeves with elastics, 19 in long | 19 in length | Not stated |
| Booties | SSB | Booties with elastic | One size | Not stated |
| Bib apron | SSA | Bib-style apron | Not stated | Not stated |
| Coat apron with sleeves | SSCA | Coat-style apron with sleeves | Not stated | Not stated |
Sources
- Honeywell/North Silver Shield / 4H Series of Gloves and Accessories, product data sheet (accessed 2026-11-14)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.