Chemical-Resistant Glove Selection Guide: Matching Glove Material to Hazard

How to read a glove chemical-resistance chart and match glove material to chemical hazard: degradation vs. penetration vs. permeation, ASTM F739 breakthrough time, ANSI/ISEA 105 classes, and a material-by-chemical-class comparison table.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

Not all chemical-resistant gloves resist the same chemicals, and a glove that looks fine after use is not necessarily still protective. This guide is a companion to CASRAI’s PPE Selection for Chemical Handling in the Lab, which covers the overall logic of glove, eyewear, and lab-coat selection but deliberately stops short of a detailed chemical-to-material comparison. Here we go deeper: how glove failure actually happens, what the numbers on a manufacturer’s chemical-resistance chart mean, how common glove materials compare against common lab chemical classes, and how to build a defensible change-out schedule.

Chemical-resistant gloves are usually made from nitrile, neoprene, butyl rubber, PVC, or Viton (fluoroelastomer), with multi-layer laminate film for the most aggressive chemicals. No single material resists every chemical: the right glove is the one whose published breakthrough time for your exact chemical, concentration, and glove product covers the task, so match the material to the hazard rather than to whatever glove is closest.

Three Ways a Glove Fails — And Why Only One Is Invisible

Under OSHA’s PPE standard for hand protection, 29 CFR 1910.138, employers must select gloves based on the specific task, the hazards present, and the glove material’s performance against those hazards — not a single all-purpose glove for the whole lab. For chemical handling, “chemical-resistant” breaks into three distinct failure modes:

  • Degradation — the glove material physically changes on contact with a chemical: swelling, softening, hardening, cracking, or dissolving. Degradation is usually visible, which is exactly why it is the least dangerous failure mode — you can see it and react.
  • Penetration — bulk liquid passes through a pinhole, tear, seam, or other physical defect in the glove. This is a manufacturing/damage issue, not a material-chemistry issue, and standard pre-use inspection (stretch, look for pinholes, check seams) catches most of it.
  • Permeation — the chemical moves through the glove material at a molecular level, without any visible sign of damage. This is the dangerous one: a glove can look and feel completely intact while chemical is already passing through it into contact with skin.

How Permeation Is Actually Measured: ASTM F739 and Breakthrough Time

Permeation resistance is measured under ASTM F739, the standard test method for measuring chemical permeation through protective clothing materials. In the test, one side of a glove material sample is exposed to the challenge chemical while a detector on the other side monitors for the chemical crossing through. The key result is breakthrough time — commonly reported as the standardized breakthrough time (SBT), the point at which the permeation rate reaches a defined threshold (100 ng/cm²/min under the current standardized method). Once breakthrough time has elapsed, the glove is considered to have failed for that chemical, even if it still looks and feels fine.

The ANSI/ISEA 105 standard (American National Standard for Hand Protection Classification) translates raw breakthrough-time data into a simple 0–6 chemical permeation resistance class that appears on many U.S. glove charts and packaging:

ANSI/ISEA 105 Class Breakthrough Time
Class 0 Less than 10 minutes
Class 1 ≥ 10 minutes
Class 2 ≥ 30 minutes
Class 3 ≥ 60 minutes
Class 4 ≥ 120 minutes (2 hours)
Class 5 ≥ 240 minutes (4 hours)
Class 6 ≥ 480 minutes (8 hours)

A higher class number means longer protection against that specific chemical, at that specific concentration and temperature — the same glove can rate Class 6 against one chemical and Class 0 against another. Labs outside the U.S., or working with equipment/PPE sourced internationally, will also encounter EN 374, the European standard for protective gloves against chemicals and micro-organisms, which uses its own breakthrough-time-based classification and a letter code (Type A, B, or C) indicating how many standard test chemicals a glove resists for at least 30 minutes. The underlying physics — degradation, penetration, permeation, and breakthrough time — is the same across both standards; only the labeling convention differs.

Reading a Manufacturer’s Glove Chart

Ansell, Honeywell/North, MAPA, Kimberly-Clark, and other glove manufacturers publish free online chemical-resistance charts that list, for each glove product, a rating (often the ANSI/ISEA 0–6 class, or a manufacturer-specific letter grade) against a long list of individual chemicals. To use one correctly:

  • Match the exact chemical, not the category. “Acid” is not a chemical — sulfuric acid and acetic acid behave very differently against the same glove material. Look up the specific compound.
  • Match the concentration. A glove rated well against a dilute acid solution can fail quickly against the concentrated form of the same acid. Charts that don’t specify concentration should be treated as a rough starting point, not a final answer.
  • Match the glove product, not just the material. “Nitrile” is a material family, not a single product — a 4-mil disposable nitrile exam glove and a 15-mil unsupported nitrile chemical glove are built from related but not identical formulations, at very different thicknesses, and will have meaningfully different breakthrough times against the same chemical. Look up the specific product line, not the generic material name.
  • Check the mixture, not just each component. Charts rate single chemicals. A glove that resists two chemicals individually may not resist a mixture of the two as well as the weaker-performing chemical alone — for genuinely novel or unusual mixtures, the safe default is to treat the mixture as the worst-case single component, or test/verify with the manufacturer.

Because different manufacturers formulate their materials differently, publish charts in different formats, and test against different chemical lists, this guide does not reproduce any single manufacturer’s chart as authoritative — always confirm against the current chart for the specific glove product in use, and cross-check, using the nitrile glove breakthrough data guide as a worked example of how that data reads, against Section 8 (Exposure Controls/Personal Protection) of the chemical’s Safety Data Sheet, which frequently specifies a recommended glove material directly.

Glove Material Comparison: General Resistance by Chemical Class

The table below summarizes typical resistance patterns for the glove materials most commonly stocked in research labs, against broad chemical classes. Treat every cell as a starting point for further lookup, not a final answer — always verify against a current manufacturer chart for the specific chemical, concentration, and glove product before relying on it.

Glove Material Ketones (acetone, MEK) Alcohols Chlorinated Solvents Strong Acids Strong Bases Aromatic Hydrocarbons (toluene, benzene) Typical Lab Role
Nitrile Poor Good Fair–Poor Fair–Good Good Fair–Poor General bench default; biological work
Natural rubber latex Poor Fair Poor Fair Fair–Good Poor Largely phased out for chemical work — allergy risk, weak solvent resistance
Neoprene Fair Good Fair Good Good Fair Broader all-around resistance than nitrile when nitrile is inadequate
Butyl rubber Excellent Good Fair–Poor Good Good Poor Aggressive ketones, esters, and gas/vapor permeation resistance
PVC (vinyl) Poor Fair Poor Good Good Poor Aqueous acids/bases, low-cost general handling
Viton (fluoroelastomer) Fair Good Excellent Good Fair Excellent Aggressive chlorinated and aromatic organic solvents
Laminate barrier film (e.g., multi-layer PE/EVOH laminates) Excellent Excellent Excellent Excellent Excellent Excellent Most aggressive/exotic chemicals; poor mechanical strength, worn as an inner glove under a sturdier outer glove

No single material is a universal answer. Nitrile is a sound default for general bench work and biological fluids but is a poor choice against acetone and many other polar solvents — one of the most common glove-selection mistakes is assuming any nitrile glove is safe for any organic solvent because it is the lab’s everyday glove. When a task involves a chemical that a given material rates poorly against, the correct response is to switch materials or double-glove, not to keep using the familiar glove for convenience.

Thickness and “Mil” Rating

Glove thickness is commonly expressed in mils (1 mil = 0.001 inch, or 0.0254 mm). Disposable exam-style gloves are typically in the 3–8 mil range and are designed for barrier protection against biological fluids and light contamination, not sustained chemical contact. For a sourcing view of the most common material, see how to specify and buy nitrile gloves for the lab, and for a side-by-side of the three common exam-glove materials see nitrile vs. latex vs. vinyl gloves. Dedicated chemical-handling gloves — supported or unsupported — commonly run 11–25+ mils and are formulated and tested specifically for longer breakthrough times against the chemicals in their published chart. Thickness alone does not determine resistance (material chemistry matters more), but for a given material, thicker generally means a longer breakthrough time and better cut/puncture resistance, at the cost of dexterity.

Related: Chemical Resistance Chart for Plastics — A practical chemical resistance reference for common lab plastics (HDPE, LDPE, PP, PTFE/PFA/FEP, PVC, PC, PS) against acids, bases, solvents and oxidizers, for choosing containers, tubing and labware.

Double-Gloving

Double-gloving — wearing a thinner, often different-material glove underneath a primary glove — is a standard mitigation for two distinct situations: working with a chemical known to have a short breakthrough time against the available primary glove material, and tasks with elevated puncture/tear risk where an inner glove provides a backup barrier if the outer glove is compromised. It is not a substitute for selecting the correct primary material; a poorly matched outer glove doubled with another poorly matched glove still fails quickly against the target chemical.

Change-Out Schedules: Time-Based, Not Just Visual

Because permeation is invisible, “the glove still looks fine” is not evidence that it is still protective. For any chemical with a known, short breakthrough time relative to the task duration, gloves should be changed on a defined schedule tied to that breakthrough time — for example, well before the standardized breakthrough time elapses, with a documented safety margin, rather than waiting for visible signs of degradation that may never appear. Gloves should also always be changed immediately after any known contact with the chemical being handled, after any visible sign of degradation or damage regardless of schedule, and between different chemical tasks to avoid cross-contamination.

Common Glove-Selection Mistakes

  • Treating “nitrile” as one product. A blue 4-mil disposable exam glove and a green 15-mil unsupported chemical glove are both nitrile but perform very differently — always check the specific product’s chart, not the material family in general.
  • Assuming dilute-chemical resistance implies concentrated-chemical resistance. Concentration changes permeation behavior; a glove rated well against a 10% acid solution is not automatically safe against the concentrated acid.
  • Ignoring the SDS glove recommendation. Section 8 of a chemical’s Safety Data Sheet often names a recommended glove material directly — check it before defaulting to whatever glove is closest at hand.
  • Skipping pre-use inspection. A quick visual check and stretch test catches penetration risk (pinholes, tears, weak seams) that no chemical-resistance chart accounts for.
  • Waiting for visible degradation before changing gloves. Permeation frequently happens with no visible sign at all — schedule-based changes for short-breakthrough-time chemicals are not optional caution, they are the actual control.

Standardizing Chemical-Resistant Glove Specifications Across Plants

Multi-site operators usually want a short, common glove list so that every plant buys against the same specification. The regulatory frame does not change from site to site: 29 CFR 1910.138(b) requires hand protection to be selected on an evaluation of its performance characteristics relative to the tasks performed, the conditions present, the duration of use, and the hazards identified, and 29 CFR 1910.132(d) requires a workplace hazard assessment, certified in writing (see the PPE hazard assessment certification guide). A corporate standard therefore works best as a tiered list keyed to hazard classes, not a single glove for every plant.

The trade-offs between the leading materials, drawn from the comparison table above, look like this:

Option Where it earns a place on a standard Trade-off to plan for
Nitrile Default for general handling, alcohols, and bases Poor against ketones; fair to poor against chlorinated and aromatic solvents
Neoprene Broader all-around resistance, including acids and bases Only fair against many organic solvents
Butyl rubber Ketones, esters, and vapor permeation resistance Poor against aromatic hydrocarbons
PVC Low-cost handling of aqueous acids and bases Poor against ketones, chlorinated and aromatic solvents
Viton Chlorinated and aromatic solvents Fair against ketones and strong bases
Laminate film Broadest chemical coverage, usually as an inner glove Weak mechanical strength, so it needs a sturdier outer glove

How to write the specification

  1. Group tasks by hazard class, such as aqueous acids and bases, alcohols, ketones, chlorinated solvents, and aromatics, then assign one primary glove product per class.
  2. Name the product, not only the material. State manufacturer, product line, and minimum thickness, because breakthrough times belong to a specific product.
  3. Require the data. Ask each supplier for the breakthrough time or ANSI/ISEA 105 class of that exact product against the chemicals in your hazard classes, with the test method (ASTM F739) and the chemical concentration stated.
  4. Allow equivalents by data, not by name. A plant or supplier may substitute a different product only if its published breakthrough data meets or exceeds the listed product’s for the same chemicals.
  5. Set change-out rules per hazard class, tied to breakthrough time as described below, so the same task is protected the same way at every site.
  6. Train and review. Under 1910.132(f), employees must be trained on what PPE is necessary, its limitations, and its proper care, maintenance, useful life, and disposal. Re-check the list whenever a chemical, concentration, or process changes; a job hazard analysis such as the one in Job Hazard Analysis for Lab Procedures is a good trigger point.

Sourcing from multiple suppliers

When plants buy from different suppliers, the performance tests that matter are the ones already on the specification: ASTM F739 permeation data for the named chemicals, the glove’s thickness, and any pinhole or leak testing the supplier can document. Practical limitations to confirm include the available size range, whether the glove is supported or unsupported, cuff length, and lot-to-lot consistency. Chart ratings are for single chemicals, so mixtures need the manufacturer’s confirmation or the worst-case single-component assumption described above.

Drum decanting, solvent transfers, and repeated glove changes

Tasks with larger volumes, such as drum decanting, create more splash and longer contact than bench pipetting, so they usually justify a thicker, longer-cuff glove from the specification instead of a disposable one. For lab procedures that need frequent glove changes, the controlling number is still breakthrough time against the chemical in use: change on the schedule that time sets and immediately after any known contact, and keep a glove that is properly rated for the solvent at the bench rather than relying on a thin exam glove for brief, repeated exposures.

How to Inspect Chemical-Resistant Gloves Before Use

Inspection catches penetration risk, which no chart accounts for. Before each use:

  • Confirm the glove is the product the task calls for and is clean, undamaged, and within its useful life.
  • Look for tears, punctures, pinholes, thin spots, and weak seams, and stretch or flex the glove to open small defects.
  • Check for signs of degradation from earlier use: swelling, stiffness, softening, tackiness, discoloration, or cracking.
  • Check the cuff and fit, so the glove covers the wrist and sleeve gap and does not restrict grip.
  • Discard any glove that fails a check. A passed inspection says nothing about permeation, which is why the change-out schedule above still applies.

Frequently Asked Questions

What’s the difference between glove degradation and permeation?

Degradation is visible physical damage to the glove material — swelling, cracking, dissolving. Permeation is invisible: the chemical moves through the intact material at a molecular level, so the glove can look completely fine while no longer providing protection. Permeation is measured by breakthrough time under ASTM F739.

What does an ANSI/ISEA 105 chemical class rating mean?

It’s a 0–6 scale translating a glove’s measured breakthrough time against a specific chemical into a simple class: Class 0 means breakthrough in under 10 minutes, Class 6 means at least 480 minutes (8 hours). The rating is specific to one chemical at a time — the same glove can carry different classes for different chemicals.

Is a nitrile exam glove safe for handling solvents like acetone?

No. Standard disposable nitrile exam gloves are thin, general-purpose barrier gloves, and nitrile as a material has poor resistance to acetone and many other polar solvents specifically — it degrades quickly. Solvent work calls for a glove material and product actually rated for that solvent, checked against a current manufacturer chart.

How often should chemical-resistant gloves be changed?

On a schedule tied to the specific chemical’s breakthrough time for the glove in use, with a documented safety margin — not simply “when they look worn.” They should also be changed immediately after any known chemical contact, any visible damage, or before switching to a different chemical task.

Does double-gloving make any glove safe for any chemical?

No. Double-gloving adds a backup barrier and is useful for short-breakthrough-time chemicals or elevated puncture risk, but it does not substitute for selecting a primary glove material genuinely rated for the chemical being handled.

Check Section 8 of that chemical’s Safety Data Sheet, and cross-check against the current chemical-resistance chart published by the glove manufacturer for the specific product (not just the material name) at the concentration actually in use.

Which chemical classes do nitrile gloves not resist well?

Nitrile rates poor against ketones such as acetone and MEK and fair to poor against chlorinated solvents and aromatic hydrocarbons such as toluene and benzene, per the material comparison above. For those, move to butyl rubber, Viton, or a laminate glove as the chemical requires, after checking the manufacturer’s chart.

What should I look for when inspecting chemical-resistant gloves?

Check for tears, punctures, pinholes, weak seams, and signs of earlier degradation such as swelling, stiffness, tackiness, or cracking, and stretch the glove to reveal small defects. Discard any glove that fails, and remember that inspection does not detect permeation.

How do I choose one chemical-resistant glove for several sites?

Assign one named glove product per hazard class, require breakthrough data for the exact product against your chemicals, and accept substitutes only on equal or better data. See the standardization section above.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Chemical-Resistant Glove Selection Guide: Matching Glove Material to Hazard

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →