Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop kjeldahl flask supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

Kjeldahl Flask: Types, Sizes, and Standards

A Kjeldahl flask is specialized glassware for nitrogen digestion. Compare ASTM E1377 sizes, neck styles, borosilicate specs, and safe handling procedures.

Written and maintained by CASRAI Editorial Board

Published

On this page

A Kjeldahl flask is specialized laboratory glassware featuring a round-bottom bulb and a long, narrow neck engineered to withstand intense thermal and chemical stress during acid digestions. Invented by Johan Kjeldahl in 1883 for the Kjeldahl method, it serves as the primary vessel for converting organic nitrogen into ammonium sulfate using boiling concentrated sulfuric acid. The spherical base ensures uniform heating while the elongated neck acts as an air condenser, returning acid vapors and preventing corrosive spatter.

Who uses it: Analytical chemists, agricultural scientists, food safety technicians, and environmental analysts use Kjeldahl flasks to digest food, feed, fertilizer, wastewater, and plant tissue samples.

What it is

A Kjeldahl flask is a heavy-wall digestion vessel designed for high-temperature wet decompositions. Total nitrogen testing requires boiling organic samples in concentrated sulfuric acid (H₂SO₄) at 340 °C to 410 °C alongside salt additives and heavy metal catalysts.

The flask contains aggressive reagents while preventing analyte loss. The round bulb provides surface area for boiling, while the tall neck provides a thermal gradient where acid vapors condense along the glass wall and wash back down into the digestion mixture. This self-refluxing action maintains constant reagent volume during cycles lasting 30 to 120 minutes.

How it works or is built

Kjeldahl flasks are fabricated from low-expansion Type I, Class A borosilicate 3.3 glass conforming to ASTM E438 and USP Type I, as outlined in our guide on borosilicate versus soda-lime laboratory glassware. Borosilicate 3.3 exhibits a low thermal expansion coefficient (approximately 3.3 × 10⁻⁶ K⁻¹), providing high thermal shock resistance and chemical durability against boiling acids. Glassware complies with ASTM E671 residual thermal stress limits through annealing.

The flask has three primary structural parts:

  • Round-Bottom Bulb: The spherical contour distributes heat evenly across electric mantle wells or gas burners. Eliminating corners prevents stress fractures and avoids unheated dead zones.
  • Elongated Straight Neck: Measuring 150 mm to 365 mm in length, the neck serves as an unjacketed air condenser, capturing acid vapors before they reach the mouth and providing clearance for exhaust manifolds.
  • Reinforced Neck Finish: Standard vessels feature a tooled, beaded rim designed to seat rubber stoppers without chipping. Jointed variants provide Standard Taper ground glass joints for closed distillation systems.

Types and variants

Kjeldahl flasks are produced in multiple styles to support different sample masses, heating racks, and distillation units:

Flask Type Typical Use Key Difference
Standard Macro Flask Macro food, feed, and soil analysis (500–800 mL). Ungraduated bulb with reinforced tooled rim for rubber stopper connections per ASTM E1377 Type I.
Micro Kjeldahl Flask Pharmaceuticals and small tissue samples (10–30 mL). Miniature dimensions conforming to ASTM E147 with square-cut or beaded rim for compact micro-blocks.
Ground Joint Flask Closed digestion setups and direct distillation hookups. Integrated Standard Taper ground joint (ST 24/40 or ST 29/42); eliminates rubber stoppers and leaks.
Graduated Flask Semi-quantitative sample preparation and reagent tracking. Permanent ceramic enamel graduation markings on bulb or neck conforming to ASTM E1377 Type II.

Sizes or specifications that matter

Kjeldahl flasks adhere to dimensional standards set by ASTM E1377 (macro flasks), ASTM E147 (micro flasks), and ISO 12360. Unlike flat-bottom vessels such as an Erlenmeyer flask or a volumetric flask, Kjeldahl flasks prioritize neck length and wall thickness over volumetric calibration.

The table below summarizes standard capacities, body diameters, heights, and stopper sizes from ASTM standards and manufacturer datasheets (Corning PYREX 5420 and DWK KIMAX 27400):

Capacity (mL) Body OD (approx. mm) Height (approx. mm) Mouth ID (approx. mm) Rubber Stopper Size Governing Standard
10 mL 30 mm 150 mm 11 mm No. 000 ASTM E147
30 mL 40 mm 180 mm 14 mm No. 0 ASTM E147
100 mL 60 mm 210 mm 18 mm No. 2 ASTM E1377 Type I
300 mL 81 mm 300 mm 25 mm No. 5 ASTM E1377 Type I
500 mL 101 mm 325 mm 29 mm No. 6 ASTM E1377 / ISO 12360
800 mL 117 mm 365 mm 32 mm No. 7 ASTM E1377 / ISO 12360

How to choose

Select a Kjeldahl flask by matching technical requirements across four parameters:

  • Sample Mass and Digestion Reagent Volume: Macro-scale samples (1.0 g to 5.0 g) require 500 mL or 800 mL flasks to accommodate 20 mL to 30 mL of acid plus initial foaming. Semi-micro analyses (0.1 g to 0.5 g) use 100 mL or 300 mL vessels. Micro-determinations (<100 mg) require 10 mL or 30 mL micro-Kjeldahl flasks.
  • Heating Unit Cavity Fit: Flask outer diameters must match the heating well geometry of digestion racks (e.g., Labconco or Buchi units). Mismatched diameters cause poor thermal contact or localized stress.
  • Connection Interface: Use tooled beaded rims for standard rubber stoppers fitted to manifold exhaust tubes. Choose Standard Taper ground joints (ST 24/40) for closed distillation assemblies where rubber-free vapor seals are required.
  • Compliance Certification: In regulated AOAC, EPA, and ISO testing, ensure glassware carries permanent marks certifying ASTM E1377, ASTM E147, or ISO 12360 compliance and Class A borosilicate composition.

Safe use and handling basics

Because Kjeldahl digestions involve boiling concentrated sulfuric acid above 340 °C, laboratories must enforce strict handling controls:

  • Fume Hood Containment: Always conduct digestions in a certified fume hood or connect flasks to an acid scrubber manifold. Acid digestions generate toxic SO₂ and SO₃ vapors that must never enter room air.
  • Anti-Bumping Granules: Always add inert boiling chips or pumice granules before heating. Concentrated acid superheats easily; nucleation chips provide smooth boiling and prevent explosive surging.
  • Pre-Use Inspection: Examine each flask under focused light before use for hairline cracks, scratches, or star fractures per glassware safety inspection rules. Damaged vessels fail catastrophically under heat.
  • Cooling Before Dilution: Allow flasks to cool for 20 to 30 minutes before adding water. Adding water to hot concentrated sulfuric acid causes violent exothermic steam eruptions. Pour dilution water slowly down the tilted neck wall.
  • Personal Protective Equipment: Wear a full-face shield over safety glasses, an acid-resistant lab coat, and heavy neoprene or nitrile chemical gloves.

Common mistakes

Common operational mistakes that compromise safety or analytical results include:

  • Omitting Boiling Granules: Heating stagnant acid without boiling stones causes severe superheating and violent bumping, expelling boiling acid or breaking the flask.
  • Direct Flame Contact: Exposing the glass bulb directly to bare heating coils causes localized hot spots. Flasks require contoured ceramic well cradles or radiant mantles.
  • Thermal Shock on Cold Surfaces: Resting a hot 380 °C flask on a cold metal or stone benchtop induces contraction fractures. Always place hot vessels on insulated digestion racks or ceramic boards.
  • Using Generic Glassware: Attempting digestions in flat-bottom Erlenmeyer flasks leads to acid escape, premature reagent dry-down, and mantle stress cracks.
  • Forcing Incorrect Stopper Sizes: Forcing an oversized rubber stopper into the tooled mouth generates hoop stress that splits the neck during heating.

FAQ

What is the primary function of a Kjeldahl flask?

A Kjeldahl flask serves as the reaction vessel for wet acid digestion during total nitrogen and protein determination. It contains boiling concentrated sulfuric acid while converting organic nitrogen into ammonium sulfate.

Why does a Kjeldahl flask have such a long neck?

The elongated neck functions as an unjacketed air condenser. It provides surface area for sulfuric acid vapors to cool, condense, and drip back into the bulb, maintaining reagent volume and preventing acid spatter.

Can an Erlenmeyer flask be used instead of a Kjeldahl flask?

No. Erlenmeyer flasks have short necks and flat bottoms that cannot safely withstand sustained 340 °C to 410 °C digestion temperatures. Their short necks permit hazardous acid escape and flat bases risk thermal fracture.

What glass material is required for Kjeldahl flasks?

Kjeldahl flasks require Type I, Class A borosilicate 3.3 glass conforming to ASTM E438 and USP Type I. This formulation provides chemical resistance against boiling mineral acids and withstands severe thermal cycling.

What is the most common size of Kjeldahl flask?

The 500 mL and 800 mL flasks are standard for food, feed, and wastewater analysis. They fit commercial multi-place digestion racks and accommodate standard 1 g to 5 g sample masses.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Kjeldahl Flask: Types, Sizes, and Standards

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →