Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop sapphire pump supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

What Is a Sapphire Pump? Modes, Drug Library and Administration Sets

Sapphire pump explained: FDA Class II classification, infusion modes, optional drug library, single-use sets and the 510(k) clearance history.

Written and maintained by CASRAI Editorial Board

Published

This page describes products and general use; it is not medical advice.

On this page

A Sapphire pump is the common name for the Sapphire infusion pump, a single-channel volumetric infusion pump cleared by the US FDA as a Class II device and used with dedicated Sapphire administration sets. This page explains how the device is classified, which delivery modes it offers, what its drug library is, and how its clearances are documented in the public FDA record. It is written for clinic staff, buyers and students.

What is a Sapphire pump?

A Sapphire pump (also searched as a “Sapphire infusion pump”) is an electronic infusion pump that delivers fluids in a controlled manner. Under 21 CFR 880.5725, an infusion pump is “a device used in a health care facility to pump fluids into a patient in a controlled manner”, and it is regulated as a Class II device with performance standards. The FDA clearance for the current Sapphire system, K192860 (decision date 2020-11-19, applicant Q Core Medical Ltd.), lists the trade name as “Sapphire Infusion Pump, Sapphire administration sets” and describes it as a “single-channel, volumetric infusion pump”.

Who uses it: the FDA summary lists licensed professionals and lay users, adult and pediatric populations, and clinical, ambulatory, pre-hospital air and ground transport, and home environments as the intended settings. For background on the regulatory class, see Class II medical devices.

How the Sapphire pump is built

According to the K192860 summary, the system consists of the pump, a set of dedicated administration sets, and optional accessories and software. Documented elements include:

  • Sensors: air-in-line and occlusion sensors.
  • Power: a 7.4 V lithium-ion battery; the pump with battery is listed at 518 g.
  • Accessories: a mini cradle, PCA lock boxes (100, 250 and 500 ml), a PCA/PCEA bolus handle, a battery charger and a battery case.
  • Software: an optional preprogrammed drug library, built with a separate “Drug library editor” program.

The summary gives a continuous-mode rate range of 0.1 to 999 mL/hr. Treat the manufacturer’s current instructions for use as the authority for any operating specification.

Infusion modes

The FDA summary states that the following modes are available “for all intended uses”, and that the software modes can each be disabled:

Mode listed in the FDA summary Notes from the record
Continuous Rate range 0.1 to 999 mL/hr is listed for this mode.
Intermittent Listed as an available mode.
TPN Listed as an available mode.
PCA Listed as an available mode; PCA lock boxes and a bolus handle are listed accessories.
Multi-step Listed as an available mode.
Epidural Listed as an available mode; delivery routes in the summary include epidural and perineural.

The intended delivery routes named in the summary are intravascular, subcutaneous, intra-arterial, perineural and epidural. How a mode is programmed for a patient is a clinical decision governed by the manufacturer’s instructions and the facility’s protocols, and is outside the scope of this page. For the arithmetic behind gravity-set flow rates, which is a different device class, see how to calculate drip rate.

The drug library

The Sapphire system offers an optional preprogrammed drug library, edited with a separate software program. In the FDA summary’s words, “the preprogrammed range limits are associated with certain drugs and/or certain modes and/or certain care areas.” In plain terms, a library lets a facility attach limits to particular drugs, modes or care areas so that the pump can be configured to the facility’s own rules. The library is optional; the contents are set by the facility, not by this page.

Administration sets

Sapphire administration sets are described as sterile, “intended for single-patient use and single-use only”. The set comparison in the FDA summary mentions non-DEHP and latex-free materials and the addition of an NRFit connector. For related tubing and fittings used in infusion lines, see Y-type tubing, three-way stopcocks and saline locks.

FDA clearance history

The openFDA 510(k) database lists these Sapphire clearances (checked 2026-11-07):

510(k) number Decision date Note
K123049 2013-10-17 Sapphire clearance
K141834 2014-08-05 Administration set (product code FPA)
K141389 2014-12-11 Sapphire clearance
K161667 2017-03-27 Sapphire clearance
K192860 2020-11-19 Sapphire Infusion Pump and administration sets; product codes FRN, MRZ, FPA

Safe use and handling basics

  • Use the administration sets made for the pump; the sets are labelled single-patient, single-use.
  • Follow the manufacturer’s instructions for use and the facility’s protocols for programming, alarms and maintenance.
  • The air-in-line and occlusion sensors are listed safety features of the system; alarm response is covered in the instructions for use.
  • Questions about an individual patient’s therapy belong with the prescribing clinician.

Common mistakes

  • Treating “Sapphire” as one generic pump class. It is a specific cleared system with its own sets; other infusion pumps are separate devices.
  • Assuming every mode, accessory or drug library is enabled on a given unit. The summary states the software modes can be disabled and the library is optional.
  • Reusing a set. The administration sets are labelled single-use.

FAQ

What is a Sapphire infusion pump?

It is a single-channel, volumetric infusion pump with dedicated administration sets, cleared by the FDA as a Class II device under 21 CFR 880.5725 (K192860, decision 2020-11-19).

Which modes does the Sapphire pump offer?

The FDA summary lists continuous, intermittent, TPN, PCA, multi-step and epidural modes, any of which can be disabled in software.

Does it have a drug library?

Yes, optionally. Range limits can be associated with certain drugs, modes or care areas, using a separate Drug library editor program.

Are the administration sets reusable?

No. The FDA summary describes them as sterile and for single-patient, single-use only.

Sources

  • FDA 510(k) K192860 clearance letter and summary, accessdata.fda.gov (read 2026-11-07).
  • 21 CFR 880.5725, Infusion pump, Cornell LII (read 2026-11-07).
  • openFDA device 510(k) API, api.fda.gov (queried 2026-11-07).

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about What Is a Sapphire Pump? Modes, Drug Library and Administration Sets

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →