HSG Catheter: Types, FDA Product Code MOV and Evidence

HSG catheter types, FDA product code MOV (class 2, 21 CFR 884.4530), five 510(k) clearances and what trials compare for balloon vs metal cannula.

Written and maintained by CASRAI Editorial Board

Published · Last updated

This page describes products and general use; it is not medical advice.

On this page

An HSG catheter is a single-patient, sterile device used to deliver contrast medium into the uterine cavity during hysterosalpingography (HSG), the radiographic examination of the uterus and fallopian tubes. Clinicians in obstetrics and gynecology and radiology use it; buyers and students usually need to know what the device class is, how it is regulated, and what published studies say about the main designs. This page covers those three questions, using the FDA’s own device records and peer-reviewed trials.

What an HSG catheter is

“HSG catheter” is a working name rather than a single regulatory category. In FDA’s device database, the product code that names catheters for this purpose is MOV, “Catheters, Salpingography”, reviewed by the Obstetrics/Gynecology panel. The designs in clinical use fall into two broad families: a balloon catheter and a rigid metal cannula. A third, more specialised design, the cornual cannulation set, is used for selective salpingography. Published studies describe the first two as the instruments used to deliver contrast medium during HSG (Kiykac Altinbas et al., 2015).

Types and variants

Type What the sources say Source
Balloon catheter (disposable) Compared with a metal cannula in a randomised trial of 168 patients; described in a case series as a “disposable HSG balloon catheter”. PMID 25141095; PMID 35084737
Metal cannula (for example, the Kahn uterine trigger cannula) The comparator in the same trial; in the case series, the cannula was used on repeat HSG in nine of 17 patients whose first HSG with a balloon catheter was technically difficult or incomplete. PMID 25141095; PMID 35084737
Cornual cannulation set / selective salpingography catheter Cleared by FDA under product code MOV; for example the Modified Novy Cornual Cannulation Set (Cook Incorporated, 510(k) K180552, decision 12 July 2018). openFDA 510(k) database

FDA classification and product code

openFDA’s device classification record for product code MOV (data last updated 19 October 2026) lists the following.

Field Value in the FDA record
Device name Catheters, Salpingography
Device class 2
Regulation number 884.4530 (21 CFR)
Review panel Obstetrics/Gynecology
Submission type 510(k)
Implant / life-sustaining No / No
Summary malfunction reporting Eligible
Third-party review Yes

The same database lists exactly five 510(k) clearances under MOV, all with a “Substantially Equivalent” decision:

  • K931476, Novy Cornual Cannulation Set, Cook Ob/Gyn (28 July 1995)
  • K931534, Ovamed Intrauterine Access Catheter, Ovamed Corp. (28 July 1995)
  • K953314, Conceptus Fallopian Tube Catheterization System, Conceptus, Inc. (28 July 1995)
  • K932436, Echomark Intrauterine Guiding Catheter, Echocath, Inc. (16 November 1995)
  • K180552, Modified Novy Cornual Cannulation Set, Cook Incorporated (12 July 2018)

What this does and does not tell you: the MOV record is the code FDA uses for salpingography catheters, and it is dominated by cornual cannulation and intrauterine access devices. It does not follow that every balloon HSG catheter on the market is listed under MOV, so a product’s own FDA listing or labelling is the place to confirm its code. Regulation 21 CFR 884.4530 is the number FDA assigns in the MOV record; the regulation itself describes a group of obstetric-gynecologic devices used for manipulative diagnostic and surgical functions where structural integrity is the chief criterion of device performance. Class II devices are subject to special controls. For background on the pathway, see FDA De Novo classification and the Medical Device Amendments of 1976.

What published studies compare

Measure Balloon catheter Metal cannula
Patients randomised (n = 168) 83 85
Pelvic pain scores (Wong Baker Faces Pain Rating Scale) Significantly lower (p < 0.001) Higher
Device reinsertion rate 2.4% 8.2%
Nausea (reported as the most common short-term adverse effect in the cannula group) 1.2% 14.1% (p = 0.002)

Source: Kiykac Altinbas S, et al. J Obstet Gynaecol 2015;35(2):193-8 (PMID 25141095). The authors concluded that the balloon catheter was advantageous for reducing pain and side effects compared with the metal cannula in this trial.

A limit of the balloon design is also documented. In a case series of 17 patients with a technically difficult or incomplete HSG using a disposable balloon catheter, which had shown false-positive findings, all had patent tubes on repeat assessment with a Kahn uterine trigger cannula, on repeat HSG (nine patients) or at tubal perfusion testing during laparoscopy (eight patients). (Youssef et al., Int J Gynaecol Obstet 2022;158(3):736-741, PMID 35084737). Both are single studies and do not rank products.

Safe use and handling basics

FDA’s AccessGUDID records for the MOV-listed Cook devices (models G26822, G17868 “Selective Salpingography Catheter With Beacon, Tip”, G17558 and G17478 “Modified Novy Cornual Cannulation Set”) label them as sterile and single use. In general, a sterile single-use device is not reprocessed or reused, and the manufacturer’s instructions for use set out the permitted use, so read the labelling that comes with the specific product. Problems with a device can be reported through FDA’s Medical Device Reporting system. This page gives no procedural steps; those belong to trained clinicians and the product’s instructions.

Common mistakes

  • Treating “HSG catheter” as one regulated product. The balloon and metal-cannula designs and the cornual cannulation sets are different devices with different labelling.
  • Assuming product code MOV covers every HSG catheter. The FDA record shows five clearances, and not every design need appear there.
  • Generalising one trial. The 168-patient comparison measured pain and side effects with one balloon catheter and one cannula; it does not rank all products.
  • Assuming a balloon catheter always gives a conclusive result. The case series above documents false-positive findings after technically difficult studies.

Frequently asked questions

What is an HSG catheter?

A sterile device used to deliver contrast medium into the uterine cavity during hysterosalpingography. FDA groups salpingography catheters under product code MOV, class 2.

Is an HSG catheter a Class II device?

Under product code MOV, “Catheters, Salpingography”, FDA’s classification record lists device class 2, 510(k) submission, regulation number 884.4530.

Is an HSG catheter single use?

The AccessGUDID records for the MOV-listed Cook devices state sterile and single use. Check the labelling of any other product.

Balloon catheter or metal cannula: what does the evidence say?

In one randomised trial of 168 patients, the balloon catheter was associated with lower pain scores, fewer reinsertions and less nausea; a separate case series shows the cannula being used when a balloon-catheter HSG was difficult or incomplete.

Sources

Related CASRAI guides on other catheter devices: intrauterine pressure catheter and Foley catheter.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about HSG Catheter: Types, FDA Product Code MOV and Evidence

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →