Written and maintained by CASRAI Editorial Board
Published
This page describes products and general use; it is not medical advice.
On this page
An intradermal needle is a hypodermic needle labelled for injection into the skin itself, usually identified by a short length (for example 3/8 in), a fine gauge and an “intradermal” bevel. Clinic staff, supply buyers and students use this page to read a product listing correctly and to see where these needles sit in FDA device regulation.
What is an intradermal needle?
“Intradermal” describes a labelling and bevel designation, not a separate regulatory device type. The FDA regulates hypodermic single lumen needles under 21 CFR 880.5570 as devices “intended to inject fluids into, or withdraw fluids from, parts of the body below the surface of the skin.” The regulation describes a sharpened metal tube with a female hub that connects to the male nozzle of a syringe or an administration set. These needles are Class II (performance standards).
In the FDA classification database (openFDA, read 12 November 2026) the matching product code is FMI, “Needle, Hypodermic, Single Lumen”, class 2, regulation 880.5570, General Hospital panel. Two other codes sit under the same regulation: NKK (reprocessed) and QNS (low dead space). No separate product code for “intradermal” was found; the word appears in manufacturer product descriptions.
Who uses it: clinical staff in settings such as allergy and tuberculosis-testing services, and the buyers who stock those settings.
How it is built
Per 21 CFR 880.5570, the needle is a sharpened metal tube (the cannula) fitted to a hub. The hub is what mates with a syringe or administration set. Manufacturer listings add further features:
- Bevel: the angled cut at the tip. Manufacturers such as BD label some products with an “intradermal bevel”. The bevel angle is not given in the sources read for this page.
- Gauge and length: printed on the listing, for example 26 G x 3/8 in. 3/8 in is about 9.5 mm (3/8 x 25.4 = 9.525).
- Safety-engineered shielding: some intradermal products add a shield that covers the needle after use. See retractable syringes for the related mechanism.
Types and variants
| Type | What the source says | Source |
|---|---|---|
| Fixed-needle syringe with intradermal bevel | BD allergist tray syringe, SKU 305951: 1 mL, needle permanently attached, hypodermic, single-use, with a safety-engineered shielding mechanism and a clear hub | BD product page |
| Tuberculin syringe with intradermal bevel | BD SafetyGlide tuberculin 303327: 1 mL, 27 G x 3/8 in, intradermal bevel (see tuberculin needles) | BD product page, checked 1 November 2026 |
| Stand-alone sterile needle | An AccessGUDID record describes “sterile, disposable surgical stainless steel intradermal needles”, 5 needles in foam per sealed bulk package, box of 50, prescription-only | openFDA UDI database |
The openFDA UDI database returned 37 records matching “intradermal” in the device description (updated 2 November 2026), so intradermal needles are listed both as stand-alone needles and as part of syringes.
Sizes and specifications
| Product | Gauge | Length | Volume |
|---|---|---|---|
| BD allergist tray syringe 305951 | 26 G | 3/8 in (about 9.5 mm) | 1 mL |
| BD SafetyGlide tuberculin 303327 | 27 G | 3/8 in (about 9.5 mm) | 1 mL |
These are two manufacturer configurations, not a standard size range. Other manufacturers and listings differ.
How to read a listing before buying
Only criteria that appear in the sources are listed here.
- Needle attachment: the BD allergy syringe has a permanently attached needle; a stand-alone needle connects through its hub. A UDI record or product page states which.
- Bevel label: check whether the listing says “intradermal bevel” rather than assuming it from the product name.
- Safety feature: BD lists a safety-engineered shielding mechanism on 305951; other listings may not.
- Sterility and prescription status: the AccessGUDID record shows sterile and prescription-only fields.
- Instructions for use: BD links an electronic IFU (eifu.bd.com) from the product page.
For allergy-clinic stocking context, see the allergy clinic supply checklist.
Safe use and handling basics
- BD describes the allergy syringe as single-use and disposable; single-use devices are not reused.
- Follow the manufacturer’s instructions for use for activating any safety shield.
- Technique, site and angle belong to clinical training and the product IFU, and are not covered here.
Related: subcutaneous syringes and the ISO 11608 needle-based injection systems standard.
Common mistakes
- Treating “intradermal” as a regulatory class. The regulation (21 CFR 880.5570) covers hypodermic single lumen needles generally.
- Assuming a gauge or length from the bevel label. 26 G and 27 G are both shown above with the same 3/8 in length.
- Assuming every intradermal listing includes a safety mechanism; check the product page.
FAQ
Is an intradermal needle a different FDA device?
No separate product code was found. Hypodermic single lumen needles are Class II under 21 CFR 880.5570 (product code FMI); “intradermal” appears in manufacturer descriptions.
What size is an intradermal needle?
It varies by product. Two BD examples are 26 G x 3/8 in (allergist tray syringe) and 27 G x 3/8 in (tuberculin syringe).
Does it come attached to a syringe?
Both forms exist: BD lists a permanently attached needle on the 305951 allergy syringe, and UDI records show stand-alone intradermal needles.
Sources
- 21 CFR 880.5570, hypodermic single lumen needle, Cornell LII, read 12 November 2026: https://www.law.cornell.edu/cfr/text/21/880.5570
- openFDA device classification, product code FMI, read 12 November 2026: https://api.fda.gov/device/classification.json?search=product_code:FMI
- openFDA/AccessGUDID UDI records for “intradermal”, read 12 November 2026: https://api.fda.gov/device/udi.json?search=device_description:intradermal
- BD product page, SKU 305951, read 12 November 2026: https://www.bd.com/en-ca/products-and-solutions/products/product-page.305951