Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
This page is general product and regulatory information for laboratory and clinic staff. It is not medical advice.
Short answer
A densitometer is an instrument that measures optical density, meaning how light passes through or reflects from a material. In FDA’s clinical laboratory definition it measures the concentration of a substance on a film or other support medium. In laboratories the word usually means a film, gel or chromatography-plate scanner. In radiology and bone health, “bone densitometer” names a different, x-ray-based device. Which one a document means decides what it measures and how FDA classifies it.
Definition and scope
The term covers more than one kind of instrument, so the first job is to establish which one is meant. Under U.S. federal regulation, FDA defines the clinical laboratory version in 21 CFR 862.2400 as a “densitometer/scanner (integrating, reflectance, thin-layer chromatography, or radiochromatogram) for clinical use”. It is a device intended to measure the concentration of a substance on the surface of a film or other support medium, by a photocell measurement of light transmission through a given area of the medium. For radiochromatogram scanners, it instead measures the distribution of a specific radioactive element on a radiochromatogram.
In that definition the substance sits on the surface of a film or other support medium, and the instrument reads the medium rather than a liquid in a cuvette.
How it is used in practice
The regulatory text names the support media and reading modes. A scanner of this type measures the concentration of a substance on the surface of a film or other support medium. The title of the regulation names the types involved: integrating, reflectance, thin-layer chromatography (TLC) and radiochromatogram scanners.
Gel and blot band quantification is a related research workflow. That workflow, and the software side of it, is covered in our guide to western blot densitometry in ImageJ, and the capture hardware options are compared in film, CCD and laser-scanner imaging for western blots.
Densitometer versus bone densitometer
The two devices share a name and little else. FDA regulates them in different parts of Title 21 with different classifications, which is a quick way to tell them apart in a catalog, a specification or a procurement document.
| Device | What the regulation says it measures | FDA class | Citation |
|---|---|---|---|
| Densitometer/scanner (integrating, reflectance, TLC or radiochromatogram) for clinical use | Concentration of a substance on the surface of a film or other support medium, by photocell measurement of light transmission through a given area; radiochromatogram scanners measure distribution of a specific radioactive element | Class I (general controls); exempt from premarket notification under subpart E of part 807, subject to 862.9 | 21 CFR 862.2400 |
| Bone densitometer | Bone density and mineral content, by x-ray or gamma-ray transmission measurements through the bone and adjacent tissues | Class II | 21 CFR 892.1170 |
Where it matters for labs, clinics and supply decisions
When a request, quote or specification says “densitometer”, check four things before treating it as the instrument you need.
- What is being read. A film, gel, blot or TLC plate points to the 862.2400 type. Bone mineral content points to the 892.1170 type.
- How it reads. The regulation describes a photocell measurement of light transmission through a given area of the medium, or, for radiochromatogram scanners, measurement of the distribution of a radioactive element. The title also names reflectance and integrating types.
- Which regulation the product cites. A Class I, 510(k)-exempt scanner and a Class II bone densitometer sit under different rules, so the regulatory line on a product listing is informative.
- Whether a different instrument is a better fit. Liquid samples in cuvettes are read by a spectrophotometer; see what is a cuvette and what is a microvolume spectrophotometer. Multiwell plates are read by a plate reader; see what is a plate reader.
Common misunderstandings
“A densitometer measures bone density.”
Only the bone densitometer does. The laboratory densitometer/scanner in 862.2400 reads a substance on a film or other support medium. For the clinical context of bone density scoring, see our guide to the FRAX score.
“It is a liquid-density meter.”
The regulatory definition concerns a substance on a support medium and light transmission through it, not the density of a liquid.
“Class I means no rules apply.”
Class I means general controls apply. The 862.2400 type is exempt from premarket notification, which is a narrower statement than being unregulated.
FAQ
What is a densitometer?
It is an instrument that measures optical density, meaning how light passes through or reflects from a material. In the FDA clinical laboratory definition, it measures the concentration of a substance on a film or other support medium using a photocell measurement of light transmission through a given area (21 CFR 862.2400, checked 2026-10-31).
How is it classified by FDA?
The clinical densitometer/scanner is Class I with general controls and is exempt from premarket notification (21 CFR 862.2400). The bone densitometer is Class II (21 CFR 892.1170). Both were checked in the eCFR on 2026-10-31.
Sources
- U.S. Code of Federal Regulations, Title 21, 21 CFR 862.2400, Densitometer/scanner for clinical use, checked 2026-10-31.
- U.S. Code of Federal Regulations, Title 21, 21 CFR 892.1170, Bone densitometer, checked 2026-10-31.