The U.S. Energy Information Administration (EIA) published its November 2026 Short-Term Energy Outlook (STEO) on November 10, 2026, with the forecast completed on November 5. It projects U.S. electricity consumption of 4,306 billion kilowatthours (BkWh) in 2026 and 4,371 BkWh in 2027, up from 4,216 BkWh in 2025. Commercial-sector sales are forecast to pass residential sales in 2026, not 2027.
What the November 2026 STEO says about electricity
EIA’s electricity, coal and renewables section states that total generation by the U.S. electric power sector will reach “a record of almost 4,390 billion kilowatthours (BkWh) in 2026, up 2.7% from the previous record set last year.” It adds that rising generation “is driven by growing demand from the commercial sector and hot temperatures this past summer.” For 2027 it forecasts slower growth of 1.2%, as continued increases in commercial and industrial demand are offset somewhat by lower residential demand from forecast milder summer weather.
The consumption figures below come from EIA’s Table 7a, U.S. Electricity Industry Overview, in billion kilowatthours.
| Measure (BkWh) | 2025 | 2026 forecast | 2027 forecast |
|---|---|---|---|
| Total consumption | 4,216 | 4,306 | 4,371 |
| Sales to ultimate customers | 4,080 | 4,171 | 4,231 |
| Residential sector | 1,519 | 1,546 | 1,539 |
| Commercial sector | 1,503 | 1,557 | 1,600 |
| Industrial sector | 1,050 | 1,061 | 1,086 |
| Electric power sector generation | 4,272 | 4,387 | 4,438 |
Total consumption grows by about 2.1% in 2026 and about 1.5% in 2027 on these figures (our arithmetic from the table). Commercial sales rise from 1,503 to 1,557 to 1,600 BkWh, while residential sales rise from 1,519 to 1,546 and then dip to 1,539.
Does commercial use overtake residential in 2026 or 2027?
In this edition, Table 7a shows commercial sales of 1,557 BkWh against residential sales of 1,546 BkWh in 2026, a margin of 11 BkWh, and a wider gap of 61 BkWh in 2027 (1,600 against 1,539). Residential was 16 BkWh ahead of commercial in 2025. Some coverage of earlier outlooks placed the crossover in 2027, so a reader comparing outlets should check which edition each one describes. The figures here are those of the November 2026 edition only, and EIA revises them every month; the next release is scheduled for December 8, 2026.
What EIA does and does not say about data centers and AI
The electricity section of the November STEO attributes the growth to the commercial sector and to hot temperatures. Table 7a has no data-center line, and the quoted passages above do not use the words “data center” or “artificial intelligence.” The commercial sector is a customer class that covers many building types, so a rise in commercial sales cannot be read from these tables as a measurement of any one use. Outlets that attribute the increase to data centers or AI are adding their own interpretation or drawing on other EIA material; this post reports only what the STEO electricity text and table state.
Prices in the same forecast
Table 7a forecasts the average U.S. residential retail price at 17.24 cents per kilowatthour in 2025, 18.17 in 2026 and 18.68 in 2027. The commercial price goes from 13.37 to 14.01 to 14.26 cents, and the industrial price from 8.51 to 9.03 to 9.16 cents. The table also lists wholesale hub prices that move very differently by region: for example PJM Western hub is forecast at $60.09 per megawatthour in 2025, $87.97 in 2026 and $90.00 in 2027, while ERCOT North hub is forecast at $37.33, $34.40 and $36.73. Prices are not adjusted for inflation.
What this means for university HPC and AI compute planning
The points below are editorial interpretation, not statements by EIA.
- Budget for national price drift, then check your own tariff. The STEO figures are national averages by customer class. A campus pays its own utility or supplier rate, so the national commercial price path (up about 4.8% in 2026 and 1.8% in 2027 in the table) is a direction of travel, not a quote.
- Regional wholesale exposure differs. The same table shows a sharp rise in one regional hub and a decline in another, so institutions in different grid regions face different forecast conditions.
- Put power in the cost model. Electricity and cooling are recurring costs of research computing. Sustainable-computing practice such as sustainable HPC and energy proportionality gives planners vocabulary for measuring energy per unit of research work.
- Recovery of facility costs. Utility costs of campus computing facilities are part of the facilities cost base that institutions recover through indirect cost recovery, so rising rates feed into negotiated rates and recharge calculations on the institution’s own cycle.
- Treat the numbers as a moving forecast. Plan with ranges and revisit when each monthly STEO arrives.
For related reading on the sustainability side of research operations, see the sustainable research domain.
Sources
- EIA, Short-Term Energy Outlook, November 2026 (released November 10, 2026; forecast completed November 5, 2026).
- EIA, Electricity, Coal, and Renewables, November 2026 STEO.
- EIA, Table 7a. U.S. Electricity Industry Overview, November 2026 STEO.