Shop chromatogram chromatograph supplies
- FDA registered
- ISO 13485
- BBB Accredited A+
Shop at LAC Health
Direct comparison
Chromatogram vs Chromatograph: Data or Instrument
Chromatogram vs chromatograph: the chromatograph is the instrument, the chromatogram is its detector-response record. IUPAC definitions and when to use each.
Written and maintained by CASRAI Editorial Board
Last updated
How do Chromatogram and Chromatograph compare side by side?
The table below compares Chromatogram and Chromatograph across 10 dimensions, from what the word means to which word to use.
Side-by-side comparison
| Dimension | Chromatogram | Chromatograph |
|---|---|---|
| What the word means | A graphical or other presentation of detector response, or of analyte concentration in the effluent, plotted against effluent volume or time (IUPAC Gold Book, chromatogram, C01071). | The assembly of apparatus for carrying out chromatographic separation (IUPAC Gold Book, chromatograph, C01072). IUPAC also lists a verb sense, 'to separate by chromatography'. |
| What kind of thing it is | A result: a plot, trace or other record produced by a run. It is data that can be inspected, annotated, integrated and archived. | Equipment: the physical system in which the separation is carried out, including the part that detects what leaves the column. |
| What it measures or contains | Detector response (or another quantity used as a measure of effluent concentration) against effluent volume or time. The peaks you read are features of this record. | It does not 'contain' peaks. It holds the stationary phase and delivers the mobile phase, and it includes a chromatographic detector, which IUPAC defines as a device that measures the change of composition of the effluent (C01074). |
| The planar chromatography exception | In planar chromatography IUPAC notes that 'chromatogram' may refer to the paper or layer carrying the separated zones, so in that setting the chromatogram can be a physical object rather than a plot. | No equivalent exception. The IUPAC definition is written for any chromatographic separation and does not depend on whether it is run in a column or on a plane. |
| Where the word appears in lab writing (editorial reading of the definitions) | Results, reports and data review: 'the chromatogram shows two peaks', 'compare the retention times on the chromatogram', 'save the chromatogram file'. | Equipment records and methods: 'the gas chromatograph was serviced', 'the sample was run on a liquid chromatograph', instrument qualification and maintenance logs. |
| Gas chromatography example | The detector-versus-time trace from a gas chromatography run, whether the detector was a flame ionization detector or a mass spectrometer. The site's guide to reading a GC chromatogram covers how to interpret it. | A gas chromatograph. IUPAC states that gas chromatography is always carried out in a column and that the mobile phase is a gas (G02578). The Birmingham chemical analysis facility lists helium, hydrogen or nitrogen as typical carrier gases. |
| Liquid chromatography (HPLC) example | The detector response versus time from an HPLC run, for example a UV absorbance trace. The site's HPLC chromatogram guide covers reading it. | A liquid chromatograph. IUPAC says liquid chromatography can be carried out in a column or on a plane (L03578) and defines HPLC as present-day liquid chromatography with very small particles and relatively high inlet pressure. |
| Does it change when the detector changes? | Yes. The same sample can give a different record on a different detector, because the y-axis is whatever the detector measures. Phenomenex lists UV, mass spectrometry, fluorescence and electrochemical detectors for HPLC, and FID, mass spectrometry, ECD and conductivity detectors for GC. | The chromatograph is the same assembly whichever record you read from it. Detectors are part of, or attach to, the chromatograph, so a change of detector is a change to the instrument configuration, not a different kind of output word. |
| Common mix-up to avoid | Calling the instrument 'the chromatogram' ('the chromatogram needs servicing'), or reading the word as a general synonym for chromatography. | Calling a trace 'the chromatograph' ('the chromatograph shows a peak at 4.2 min'). IUPAC reserves the word for the apparatus. |
| Which word to use | Use chromatogram when the sentence is about the result: peaks, retention time, baseline, integration, a saved data file, or a plate in planar work. | Use chromatograph when the sentence is about the equipment: qualification, maintenance, configuration, purchase specifications, or which instrument ran the sample. |
Sources
- IUPAC Gold Book chromatogram C01071 (https://dev.goldbook.iupac.org/terms/view/C01071/plain)
- IUPAC Gold Book chromatography C01075 (https://dev.goldbook.iupac.org/terms/view/C01075/plain)
- IUPAC Gold Book chromatographic detector C01074 (https://dev.goldbook.iupac.org/terms/view/C01074/plain)
- Phenomenex, HPLC vs GC (https://phenomenex.com/knowledge-center/gc-knowledge-center/hplc-vs-gc)
- read 2026-11-20
- IUPAC Gold Book chromatograph C01072 (https://dev.goldbook.iupac.org/terms/view/C01072/plain)
- IUPAC Gold Book gas chromatography G02578 (https://dev.goldbook.iupac.org/terms/view/G02578/plain)
- IUPAC Gold Book liquid chromatography L03578 (https://dev.goldbook.iupac.org/terms/view/L03578/plain)
- University of Birmingham, Chromatography introduction (https://www.birmingham.ac.uk/research/centres-institutes/facility-for-chemical-and-materials-analysis/chromatography/introduction)
Ask CASRAI · free to try
Ask about Chromatogram vs Chromatograph: Data or Instrument
2 free questions a day, no account.
An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.
Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.
Works on this site and inside Claude, Cursor and the AI tools you already use.
Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.
Common questions
Common questions about Chromatogram vs Chromatograph
What is the difference between a chromatogram and a chromatograph?
+
A chromatograph is the instrument: IUPAC defines it as the assembly of apparatus for carrying out chromatographic separation. A chromatogram is the output: a graphical or other presentation of detector response, or analyte concentration in the effluent, against effluent volume or time. You operate a chromatograph and you read a chromatogram. IUPAC Gold Book entries C01072 and C01071, read 2026-11-20.
Is 'chromatograph' ever a verb?
+
Yes. The IUPAC Gold Book lists a verb entry for chromatograph, 'to separate by chromatography', alongside the noun for the apparatus. The noun sense is the instrument; the verb sense is the action. Neither means the plotted result, which is the chromatogram.
What are two types of chromatography?
+
Gas chromatography and liquid chromatography are the two most commonly contrasted. IUPAC defines gas chromatography as a separation technique in which the mobile phase is a gas and which is always carried out in a column, and liquid chromatography as one in which the mobile phase is a liquid, carried out in a column or on a plane. IUPAC's chromatography entry also relates many other types, among them adsorption, affinity, ion-exchange, exclusion, planar and supercritical fluid chromatography.
Which one is better, GC or HPLC?
+
Neither is better in general; the choice follows the analyte. Phenomenex describes HPLC as suited to non-volatile and thermally unstable compounds and GC as suited to volatile organics, with GC operating at roughly 150 to 300 C to vaporize samples. The University of Birmingham facility gives GC a molecular weight range of up to a few hundred and HPLC a few hundred to millions. The data table below sets the two kinds of chromatograph side by side.
What is the difference between GC and MS?
+
They are not alternatives. GC is a separation technique (IUPAC G02578), while a mass spectrometer is a detector that Phenomenex lists among the detectors used with GC and with HPLC. A GC-MS system is a gas chromatograph with a mass spectrometer as its detector, and the chromatogram it produces plots the mass spectrometer's response against time. See the site's comparison of GC-MS and LC-MS for the combined systems.
Why does the IUPAC wording matter in a methods section?
+
A methods section should name the equipment and the result separately: the chromatograph (with its mode, column and detector) is the equipment, and the chromatogram is what you show, integrate or deposit as data. Using the two words as IUPAC defines them keeps an instrument description from being read as a data claim, and the reverse.
Data: Gas and liquid (HPLC) chromatographs compared: mobile phase, columns, temperature, analytes and detectors
Side-by-side apparatus parameters for a gas chromatograph and an HPLC liquid chromatograph, compiled from a university core-facility introduction to chromatography and a manufacturer knowledge-center comparison, with IUPAC definitions for the technique names. Ranges are as stated by each source.
Period covered: 2026.
| Parameter | Gas chromatograph (GC) | Liquid chromatograph (HPLC) |
|---|---|---|
| Mobile phase | A single high-purity gas such as helium, hydrogen or nitrogen | A liquid, for example water with acetonitrile or methanol |
| Format of the separation | Always in a column (IUPAC) | In a column or on a plane for liquid chromatography generally (IUPAC) |
| Typical column length | 15 to 100 m | 50 to 250 mm |
| Typical column internal diameter | 0.25 to 0.53 mm | 2.0 to 4.6 mm |
| Operating temperature | Elevated so the analyte stays gaseous; roughly 150 to 300 C (Phenomenex) | Mostly ambient; roughly 20 to 40 C, to about 90 C in some modes (Phenomenex) |
| Analyte suitability | Volatile organics; molecular weight up to a few hundred | Non-volatile and thermally unstable compounds; molecular weight from a few hundred to millions |
| Detectors named by the sources | Flame ionization (FID), mass spectrometry, electron capture (ECD), conductivity | UV, refractive index, mass spectrometry, fluorescence, electrochemical |
| Detector destructiveness | Largely destructive, for example FID | Non-destructive detectors common, for example UV and refractive index |
Sources
- University of Birmingham, Facility for Chemical and Materials Analysis: Chromatography introduction (accessed 2026-11-20)
- Phenomenex: HPLC vs GC (accessed 2026-11-20)
- IUPAC Gold Book: gas chromatography (G02578) (accessed 2026-11-20)
- IUPAC Gold Book: liquid chromatography (L03578) (accessed 2026-11-20)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.