Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop hemovac wound vac supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

Direct comparison

Hemovac vs Wound Vac: Parts and FDA Class

Hemovac vs wound vac compared: a manual closed drain (Class I) vs NPWT (Class II), with parts, capacity and 21 CFR 878 citations.

Written and maintained by CASRAI Editorial Board

Last updated

How do Hemovac (manual closed-suction wound drain) and Wound vac (negative pressure wound therapy) compare side by side?

The table below compares Hemovac (manual closed-suction wound drain) and Wound vac (negative pressure wound therapy) across 12 dimensions, from what it is to when each is described as used.

Side-by-side comparison

DimensionHemovac (manual closed-suction wound drain)Wound vac (negative pressure wound therapy)
What it isA closed drain that removes fluid from surgical wounds; a thin tube runs from the wound to a small container (Cleveland Clinic).A device or system indicated for wound management by applying negative pressure to the wound to remove fluids, including exudate, irrigation fluids and infectious materials (21 CFR 878.4683).
Main partsDrain tube leading from the wound plus a container with flexible sides and springs. An AccessGUDID record for a Hemovac Wound Drainage System lists a PVC drain with trocar assembly and evacuator tubing.Per FDA's special controls guidance: a vacuum source, dressings that pack and seal the wound, a conduit for removing fluid from the wound bed, and a container to collect waste.
How suction is producedManually: the container's flexible sides and springs create suction when squeezed (Cleveland Clinic). Regulation describes a manually operated plastic, disposable evacuation system (21 CFR 878.4680).By a vacuum source. Non-powered NPWT suction apparatus is covered by 21 CFR 878.4683; AC- or compressed-air-powered portable suction pumps are covered by 21 CFR 878.4780.
Where the suction actsOn fluid in the surgical wound through the drain tube.On the wound through a dressing that packs and seals it, with fluid carried away through a conduit (FDA guidance).
Container volumeCleveland Clinic gives a Hemovac container capacity of about 500 mL, compared with about 25 to 50 mL for a Jackson-Pratt bulb.Volume depends on the canister of the particular system; FDA's guidance lists the waste container as a required component but this page gives no figure because none is set by the regulation.
FDA regulation21 CFR 878.4680, nonpowered single patient portable suction apparatus. Product code GCY (openFDA).21 CFR 878.4683 (non-powered NPWT apparatus); powered pumps 21 CFR 878.4780; openFDA product codes include OKO, QPX (non-powered NPWT), OMP (powered NPWT pump) and QFC (NPWT device, 21 CFR 878.4783).
FDA classClass I (general controls), exempt from premarket notification subject to 21 CFR 878.9.Class II. For non-powered NPWT the special control is FDA's 2010 guidance document; powered suction pumps are also Class II.
Single-use statusDescribed as disposable in the regulation; the AccessGUDID Hemovac record is flagged single-use.Dressings and canisters are components of the system; the regulations do not state a single rule for the whole system, so check the manufacturer's instructions for use.
How long it is in placeCleveland Clinic: may stay several days, up to about two weeks; the surgeon or care team removes it.No duration is set by the regulations or the FDA guidance read for this page; duration is set by the treating team.
Powered versus manualDefined as a manually operated system; no electric or compressed-air power source appears in the 21 CFR 878.4680 definition.Powered systems use a portable AC- or compressed-air-powered suction pump (21 CFR 878.4780, Class II). The openFDA code OMP is an NPWT powered suction pump; QFC (21 CFR 878.4783) is an NPWT device for reduction of wound complications used with dressings under 878.4780.
Organ-space woundsNot addressed by the Hemovac regulation read; the definition refers to suction drainage of surgical wounds.The openFDA classification for QFC states that it does not include devices intended for organ space wounds.
When each is described as usedSuction drainage of surgical wounds (21 CFR 878.4680); Cleveland Clinic: removes fluid from surgical wounds.Management of wounds, burns, flaps and grafts (21 CFR 878.4683). The choice for any patient is the clinician's.

Sources

  • 21 CFR 878.4680 (Cornell LII, read 2026-11-12)
  • Cleveland Clinic Hemovac drain page
  • AccessGUDID
  • 21 CFR 878.4683 and 878.4780 (Cornell LII, read 2026-11-12)
  • FDA special controls guidance (10 Nov 2010)

Ask CASRAI · free to try

Ask about Hemovac vs Wound Vac: Parts and FDA Class

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Common questions

Common questions about Hemovac (manual closed-suction wound drain) vs Wound vac (negative pressure wound therapy)

Is a Hemovac the same as a wound vac?

+

No. A Hemovac is a manual closed-suction drain whose spring container collects fluid from a surgical wound. A wound vac is a negative pressure wound therapy system with a vacuum source, a sealed dressing, a conduit and a canister. FDA regulates them under different sections of 21 CFR part 878 and in different classes.

What is the difference between a wound vac and a Hemovac?

+

The wound vac applies negative pressure across the wound through a dressing that packs and seals it; the Hemovac draws fluid out through a drain tube into a spring-driven container. The Hemovac is Class I (21 CFR 878.4680); non-powered NPWT apparatus is Class II (21 CFR 878.4683).

Is a Hemovac a type of wound vac?

+

No. Both remove fluid from wounds using suction, but a Hemovac is a manually operated disposable evacuation system, while a wound vac is a NPWT system classified separately by FDA.

How much does a Hemovac hold?

+

Cleveland Clinic gives about 500 mL for the Hemovac container, compared with about 25 to 50 mL for a Jackson-Pratt drain. Containers on other products vary.

Does FDA classify a Hemovac differently from a wound vac?

+

Yes. Manual portable suction apparatus for surgical-wound drainage is Class I and exempt from premarket notification (21 CFR 878.4680). Non-powered NPWT suction apparatus is Class II with special controls (21 CFR 878.4683).

What does NPWT stand for?

+

Negative pressure wound therapy. FDA's regulation 21 CFR 878.4683 describes a non-powered suction apparatus intended for NPWT as indicated for wound management by applying negative pressure to the wound to remove fluids, including wound exudate, irrigation fluids and infectious materials.

Does a Hemovac need FDA premarket notification?

+

Under 21 CFR 878.4680 the device is Class I and exempt from the premarket notification procedures of subpart E of part 807, subject to the limitations in 21 CFR 878.9. FDA's openFDA record lists historic Hemovac clearances (for example K800577) under product code GCY.

What are the four parts of a negative pressure wound therapy device?

+

FDA's 10 November 2010 special controls guidance describes a generic NPWT device as a vacuum source, dressings that pack and seal the wound, a conduit for removing fluid from the wound bed and a container to collect waste.

Which one does a patient need?

+

That is a clinical decision for the surgeon or care team and cannot be answered from a device comparison. Ask the treating team about the device placed for you.

Data: Hemovac-type manual suction drains versus NPWT (wound vac) devices: US FDA regulatory cross-walk

Compares the Code of Federal Regulations section, FDA class, premarket-notification status and described purpose of a manual closed-suction wound drain (Hemovac type) with non-powered and powered negative pressure wound therapy devices, compiled from the text of 21 CFR part 878 as read on 2026-11-12.

Period covered: 2026. Coverage: United States.

Hemovac-type manual suction drains versus NPWT (wound vac) devices: US FDA regulatory cross-walk
Device type21 CFR sectionFDA classExempt from 510(k) (subject to 878.9)Described purpose
Nonpowered single patient portable suction apparatus (Hemovac type)878.4680IYesSuction drainage of surgical wounds
Non-powered suction apparatus for NPWT878.4683IINo (special controls guidance, 2010)Wound management with negative pressure; removal of exudate, irrigation fluids and infectious materials; wounds, burns, flaps, grafts
Powered suction pump (AC- or compressed-air-powered)878.4780IINoRemove infectious materials from wounds or fluids from a patient's airway

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →