Accordion Drain vs Hemovac: Differences & Parts

Accordion drain vs Hemovac compared: learn the mechanical differences, bellows vs spring suction, reservoir volume, catheter sizing, and FDA Class I rules.

Written and maintained by CASRAI Editorial Board

Last updated

How do Accordion drain (bellows evacuator) and Hemovac (spring-loaded evacuator) compare side by side?

The table below compares Accordion drain (bellows evacuator) and Hemovac (spring-loaded evacuator) across 10 dimensions, from device design and structural geometry to selection criteria and clinical decision guidance.

Side-by-side comparison

DimensionAccordion drain (bellows evacuator)Hemovac (spring-loaded evacuator)
Device design and structural geometryAn accordion drain, clinically designated as a bellows evacuator (such as the Bard ReliaVac or Medline bellows systems), is engineered with an oval or cylindrical chamber featuring multiple concentric, collapsible polymer pleats along its side walls. When uncompressed, the molded walls maintain an open, expanded cylindrical profile with clear volumetric graduations. The device incorporates a top or side inlet port with an integrated anti-reflux valve, a dedicated pour spout sealed with an attached friction-fit or luer plug, and often an attachment eyelet for securing the reservoir to patient garments. The flexible corrugated pleats allow multi-axial vertical compression without requiring internal metallic components.The Hemovac wound drainage system (originally pioneered by Snyder Laboratories and manufactured by Zimmer Biomet) consists of a low-profile, rigid-rim circular canister formed by two rigid polyethylene or polypropylene plates connected by flexible sidewall membranes. Inside the reservoir, three stainless steel compression springs are positioned equidistant around the center to provide continuous outward mechanical force. The top plate features two inlet ports with internal flutter or ball-style non-return valves, depth-indicator connectors, and an evacuation pour spout with a tethered sealing stopper. The rigid circular perimeter maintains structural stability even when fully evacuated.
Suction activation and mechanical vacuum sourceSuction is generated exclusively through manual vertical compression of the polymer bellows. The clinician or caregiver places the evacuator on a flat surface, uncaps the exhaust/pour spout, depresses the top plate downward until all internal accordion pleats are fully compressed together, and securely reseals the plug before releasing pressure. The natural elastic shape memory of the molded thermoplastic walls exerts an outward restoring force as the pleats attempt to expand to their resting geometry, drawing air and wound exudate into the chamber under continuous, non-powered suction.Suction is activated by placing the open Hemovac container on a firm surface, manually pressing the top and bottom rigid plates firmly together to fully compress the three internal stainless steel coil springs, expelling air through the open pour spout, and tightly capping the stopper before releasing manual compression. Once sealed, the compressed internal springs push continuously upward against the top plate, creating an internal vacuum that pulls wound fluid through the connected perforated catheter into the container chamber without external electrical or pneumatic power.
Negative pressure dynamics and suction profilesBellows-style accordion evacuators generate a low-to-medium negative pressure profile, typically measuring between -25 mmHg and -55 mmHg (-3.3 kPa to -7.3 kPa) when fully compressed. Because suction is governed by polymer elasticity, the vacuum curve exhibits a moderate drop as the bellows fills with fluid and the pleats approach their neutral relaxed state. This gentler, self-limiting pressure profile minimizes the risk of delicate microvascular tissue trauma, flap compromise, or invagination of surrounding soft tissue into the drain tube perforations.Spring-loaded Hemovac evacuators provide a moderate-to-high negative pressure profile, with bench testing demonstrating initial peak negative pressures ranging from -70 mmHg to -95 mmHg (-9.3 kPa to -12.7 kPa) in standard 400 mL configurations. The linear mechanical spring rate maintains sustained negative pressure across a broader range of the collection cycle, although suction progressively decreases as fluid volume accumulates and counteracts spring deflection. The sustained vacuum is tailored to evacuate dense, viscous hematomas from deep surgical wounds.
Reservoir volume capacity and graduation markingsAccordion evacuators are manufactured across diverse volume configurations to accommodate specific procedural scales. Standard compact configurations include 100 cc, 150 cc, and 200 cc models designed for low-to-moderate drainage, while larger general-purpose models provide up to 400 cc capacity (such as the ReliaVac 400). The clear translucent reservoir walls feature external graduated calibration lines, typically marked in 10 mL increments up to the maximum calibrated fill volume. Certain specialized surgical systems attach an external 700 mL gravity overflow drainage bag.The standard Hemovac evacuator features a nominal volume capacity of 400 mL (commonly described in surgical catalogs as 400 cc). Compact or mini Hemovac variants (such as Snyder 100 mL kits cleared under K800542) provide 100 mL volume for localized pediatric or minor orthopedic procedures. The transparent side walls of the 400 mL unit feature calibrated graduations in 25 mL or 50 mL increments. Specialized Hemovac autotransfusion configurations (H.A.S.) utilize 600 mL canisters or attach disposable 450 mL secondary exudate collection bags with one-way flutter valves.
Catheter compatibility and tubing connectionsAccordion systems interface with various flexible radiopaque surgical catheter configurations, predominantly silicone flat drains (ranging from 7 mm to 10 mm widths) and round perforated silicone catheters (ranging from 10 Fr to 19 Fr, or 3.3 mm to 6.3 mm outer diameter). Catheters feature precision hole patterns (such as 10-inch perforated segments) with embedded continuous barium sulfate radiopaque stripes for radiographic confirmation. Systems frequently bundle Y-connectors for dual-drain insertion and pre-attached stainless steel curved trocars for subcutaneous tunnel placement.Hemovac systems accommodate both medical-grade polyvinyl chloride (PVC) and silicone perforated catheters in standard fractional outside diameters: 1/8 inch (10 Fr, approx. 3.2 mm), 3/16 inch (15 Fr, approx. 4.8 mm), and 1/4 inch (19 Fr, approx. 6.4 mm). Catheters are manufactured with 90-degree offset round perforations to prevent kinking-induced occlusion, depth indicator markings situated 5 cm from the perforation zone, and an embedded radiopaque stripe. Standard kits include single or dual stainless steel cutting trocars (5-inch or 6-inch lengths) and stepped multi-adapter Y-connectors.
Anti-reflux mechanisms and infection controlTo prevent retrograde contamination and accidental fluid backflow into the surgical cavity during manual compression, accordion evacuators incorporate an internal one-way silicone flap valve or duckbill check valve directly at the fluid inlet port. When fluid is drawn from the patient into the chamber, positive pressure during emptying or handling forces the valve closed, preventing exudate from returning up the catheter. The pour spout is isolated from the patient line, ensuring an aseptic closed fluid path when drained into graduated measurement vessels.Hemovac systems incorporate internal non-return check valves—utilizing dual silicone flutter valves or ball-check mechanisms—located at the dual catheter inlet ports on the top plate. These prevent fluid and air from refluxing into the subcutaneous wound bed when the reservoir is compressed for reactivating suction. In advanced infection-control variants, the evacuator connects via a closed-loop transfer port to a secondary exudate collection bag, allowing fluid disposal without exposing healthcare workers to open blood-borne aerosol splatters.
Primary surgical indications and clinical dead-space managementAccordion drains are predominantly utilized in surgical procedures where delicate soft-tissue flap approximation and moderate fluid evacuation are necessary. Common clinical specialties include plastic and reconstructive surgery (abdominoplasty, breast reconstruction, tissue expansion), otolaryngology and head/neck dissections (thyroidectomy, parotidectomy), vascular surgery, and localized soft-tissue subcutaneous seroma or hematoma prevention. Their compact profile and gentler negative pressure prevent collapse of microvascular anastomoses and thin cutaneous flaps.Hemovac drains are the clinical gold standard in high-volume, deep-cavity surgical procedures where significant bloody exudate, serosanguinous pooling, and heavy dead-space fluid accumulations are expected. Primary surgical disciplines include major orthopedic surgery (total hip arthroplasty, total knee arthroplasty, spinal decompression and fusion), complex pelvic trauma reconstruction, major oncologic soft-tissue resections, and radical mastectomies with axillary node clearance. The high initial suction force effectively evacuates viscous blood and prevents joint hematomas.
FDA device classification and product regulationUnder US Food and Drug Administration (FDA) regulations, non-powered accordion/bellows evacuators are categorized under 21 CFR 878.4680 as 'Apparatus, Suction, Single Patient Use, Portable, Nonpowered', assigned FDA product code GCY within the General and Plastic Surgery specialty panel. They are classified as Class I medical devices, generally exempt from 510(k) premarket notification requirements unless bundled into specialized surgical catheter kits governed under 21 CFR 878.4780 (product code OTK, Class II). Examples include Bard ReliaVac systems listed under AccessGUDID DI 20801741049525.The Hemovac wound drainage system is regulated under 21 CFR 878.4680 as a Class I non-powered suction apparatus (product code GCY, General and Plastic Surgery panel), originally cleared through landmark 510(k) premarket notifications including K800577 (Snyder Hemovac Vented Wound Kit), K800542 (100 mL Snyder Hemovac), and K843906. Specialized configurations intended for intraoperative autologous blood collection and reinfusion are separately regulated under 21 CFR 868.5830 (product code CAC, Class II), such as the Hemovac Blood Reinfusion System (K041525). AccessGUDID identifier: 00889024378834.
Bedside maintenance and re-activation considerationsBedside management requires routine monitoring of the accordion pleats to verify continuous mechanical vacuum. If the pleats have fully expanded, suction ceases and the unit must be emptied and re-compressed. Fluid is emptied by opening the pour spout, pouring effluent into a calibrated cup to record color and volume, squeezing the bellows flat against a clean surface to expel residual air, and resealing the cap before releasing. Because the polymer walls lack rigid metal springs, the evacuator can be easily squeezed with one hand or pressed flat against a table.Bedside maintenance of a Hemovac involves inspecting the spring container to verify that the top and bottom plates remain compressed near one another. As fluid fills the 400 mL chamber, the internal springs push the plates apart, indicating diminishing suction. Emptying involves unclapping the pour spout plug, inverting the container over a graduated cylinder, measuring drainage, placing the empty unit on a firm table, and depressing the top plate with two palms until the internal springs are fully compressed before tightly replugging the stopper. The rigid springs require firmer downward force.
Selection criteria and clinical decision guidanceSelect an accordion/bellows evacuator when: (1) expected 24-hour drainage volume is low to moderate (typically 50 mL to 200 mL); (2) the surgical site involves delicate skin flaps, subcutaneous fat, or microvascular reconstructions that require low-negative-pressure suction to avoid tissue trauma; (3) a compact, lightweight lateral footprint is desired for patient ambulation; and (4) flat silicone radiopaque drains are preferred over rigid large-bore PVC tubing. Common in outpatient plastic surgery, thyroidectomy, and localized soft-tissue dissections.Select a spring-loaded Hemovac evacuator when: (1) expected drainage volume is moderate to high (200 mL to 400+ mL in the first 24 to 48 hours); (2) the operative site is a deep muscular or bony cavity following major orthopedic reconstruction (total hip, total knee, spinal surgery) where high negative pressure is critical to prevent joint capsule distension; (3) large-bore semi-rigid PVC or heavy silicone drains (15 Fr to 19 Fr) are required to evacuate thick sanguineous fluid; and (4) durable rigid-walled housing is needed to resist bedside compression or accidental patient crushing.

Ask CASRAI · full access

Ask about Accordion Drain vs Hemovac: Differences & Parts

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Common questions

Common questions about Accordion drain (bellows evacuator) vs Hemovac (spring-loaded evacuator)

What are the types of surgical drains?

+

Surgical drains are broadly categorized by their mechanical mechanism (active versus passive) and their environmental exposure (open versus closed). Active drains use mechanical or electrical negative pressure (suction) to actively pull fluid from the wound bed into an external container. Common active closed drains include spring-loaded evacuators (Hemovac), bellows-style evacuators (accordion drains), bulb-suction reservoirs (Jackson-Pratt or JP drains), and powered negative pressure wound therapy (NPWT, such as Wound Vacs). Passive drains rely entirely on gravity, capillary action, or internal tissue pressure to guide fluids out of the body without suction. Common passive drains include the flat, flexible latex or silicone Penrose drain (an open system that empties onto absorbent gauze dressings), the T-tube or Kehr tube (a closed passive biliary drain that empties via gravity into a bile collection bag), and corrugated drainage sheets. Closed systems are strongly preferred in modern surgery because they isolate the wound effluent from environmental pathogens, substantially reducing the risk of retrograde surgical site infections.

How much does a Hemovac hold?

+

A standard full-size Hemovac evacuator holds a nominal maximum fluid capacity of 400 milliliters (mL), which is equivalent to 400 cubic centimeters (cc). This volume is calibrated with visible measurement graduations marked along the translucent side wall of the canister, typically spaced in 25 mL or 50 mL increments. In specialized clinical applications, alternative sizes exist: compact or 'mini' Hemovac systems (such as the Snyder 100 mL kit cleared under FDA 510(k) K800542) provide a 100 mL capacity designed for pediatric patients, hand surgery, or low-drainage procedures. Additionally, certain high-drainage configurations pair the 400 mL primary spring evacuator with an attachable secondary disposable exudate collection bag holding up to 450 mL of supplementary drainage, or connect to a 600 mL autotransfusion canister (Hemovac Autotransfusion System) for intraoperative blood salvage and postoperative filtration in total joint arthroplasty.

Can nurses pull out JP drains?

+

Licensed registered nurses (RNs) can pull out Jackson-Pratt (JP) drains and other closed-suction surgical drains when authorized by a specific licensed independent practitioner's (physician, surgeon, physician assistant, or nurse practitioner) clinical order and conducted in strict accordance with institutional nursing policies, state nurse practice acts, and documented clinical competency standards. Drain removal is typically ordered once 24-hour drainage volume drops below a safe predetermined clinical threshold (often less than 25 mL to 30 mL over a 24-hour period, or when fluid transitions to clear serous exudate). In inpatient surgical units, acute postoperative floors, and outpatient surgical clinics, bedside RNs routinely perform drain discontinuation using aseptic technique, releasing suction before gentle manual withdrawal, inspecting the tip for completeness, and dressing the puncture site. This page provides general medical device and regulatory information; it does not provide procedural nursing instructions or individual clinical guidance.

Are Hemovac and Wound Vac the same?

+

No, a Hemovac and a Wound Vac (negative pressure wound therapy, or NPWT) are fundamentally different medical devices designed for distinct clinical indications, operating mechanisms, and anatomical placements. A Hemovac is a non-powered, mechanical closed-wound surgical drain regulated under 21 CFR 878.4680 as a Class I medical device (product code GCY). It uses internal stainless steel springs to create manual, self-contained negative pressure that evacuates internal blood and serous fluid from deep surgical dead spaces through an implanted, perforated subcutaneous catheter. In contrast, a Wound Vac (such as the 3M KCI V.A.C. system) is an externally powered, computerized electromechanical pump regulated under 21 CFR 878.4780 as a Class II medical device (product code OMP). It applies precise, continuous or intermittent negative pressure (typically -75 mmHg to -125 mmHg) to an external open surface wound, utilizing reticulated open-cell foam or gauze dressings sealed with an airtight polyurethane adhesive drape to stimulate granulation tissue formation, reduce wound edema, and accelerate open wound closure.

How do accordion drains compare to Jackson-Pratt (JP) bulb drains?

+

Both accordion drains and Jackson-Pratt (JP) drains are manual, active closed-suction drainage systems, but they differ in reservoir geometry, capacity, and suction characteristics. A Jackson-Pratt drain utilizes a flexible, silicone grenade-shaped bulb with an internal volume typically ranging from 100 mL to 400 mL (most commonly 100 mL). The bulb is compressed in the clinician's hand to activate suction. Accordion drains feature a multi-pleated cylindrical or oval bellows chamber that collapses vertically along its pleated axis. While standard 100 mL JP bulbs provide an initial negative pressure of approximately -60 mmHg to -80 mmHg, bellows-style accordion evacuators often provide a gentler, more uniform low-pressure vacuum profile (-25 mmHg to -55 mmHg). Accordion drains also frequently incorporate integrated anti-reflux valves and can connect directly to hanging overflow collection bags, making them versatile for moderate-volume plastic and general surgical procedures.

What happens if a closed suction drain loses its vacuum?

+

When an active closed-suction drain—such as an accordion bellows or a spring-loaded Hemovac—loses its internal vacuum, it ceases active fluid evacuation and functions merely as a passive conduit. Loss of vacuum typically occurs when the reservoir reaches full fluid capacity, when the sealing pour-spout stopper becomes loose, or when air leaks into the closed system around an insertion site suture or tubing connection. Without active negative pressure, fluid can pool within internal surgical dead spaces, increasing the clinical risk of seroma formation, deep hematoma distension, wound dehiscence, and secondary bacterial proliferation. Bedside protocols mandate regular inspection of the evacuator reservoir: if the bellows has expanded or the Hemovac springs have fully recoiled, the container must be emptied in an aseptic manner, measured, and fully re-compressed to re-establish the prescribed therapeutic vacuum.

Data: Closed-wound surgical drainage evacuators: mechanical and regulatory specifications

Comparative technical specifications of closed-wound surgical drainage evacuators compiled from manufacturer instructions for use, AccessGUDID device records, and US FDA 510(k) premarket notifications. Compares reservoir mechanism, nominal volume capacity, negative pressure profile, FDA product code, and 21 CFR regulatory classification.

Period covered: 2026. Coverage: United States.

Closed-wound surgical drainage evacuators: mechanical and regulatory specifications
Device model and manufacturerReservoir mechanismNominal capacity (mL)Typical negative pressure (mmHg)FDA regulation numberFDA product code and class
Zimmer Hemovac 400 mL Evacuator (00-2500-700-10)Internal stainless steel coil springs (3-spring assembly)400-70 to -9521 CFR 878.4680GCY (Class I)
Snyder Mini Hemovac Kit (K800542)Internal stainless steel coil springs (miniature format)100-60 to -8521 CFR 878.4680GCY (Class I)
C. R. Bard ReliaVac 400 Evacuator (0070510)Pleated polymer bellows with elastomeric memory400-30 to -5521 CFR 878.4680GCY (Class I)
C. R. Bard ReliaVac 100 Evacuator (0090370)Pleated polymer bellows with elastomeric memory100-25 to -4521 CFR 878.4680GCY (Class I)
Medline 400 cc Bellows Closed Wound Evacuator (DYND400)Corrugated accordion bellows with anti-reflux valve400-30 to -5021 CFR 878.4680GCY (Class I)
Zimmer Hemovac Autotransfusion System (H.A.S. K041525)Internal spring canister paired with blood filtration chamber600-70 to -9021 CFR 868.5830CAC (Class II)

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →